Ventilation Options for IPL-1
For a functional unit the core system requires a suitable ventilation system. For only positive ventilation a mouse ventilator can be used. If positive and sub-atmospheric pressure ventilation are required, the Ventilation Control Module must be purchased.
For a functional unit the core system requires a suitable ventilation system. For only positive ventilation a mouse ventilator can be used. If positive and sub-atmospheric pressure ventilation are required, the Ventilation Control Module must be purchased.
Positive and Sub-Atmospheric (Negative) Pressure Ventilation with Ventilation Control Module (VCM)
- Used to control the ventilation of the isolated lung preparation. Allows for the physiological negative pressure ventilation of the lung and positive ventilation during preparation.
- 30 to 100 breaths per minute.
- I:E ratio can be set between 10 and 90% in 10% steps.
- End-inspiratory, end-expiratory, sigh, positive and negative pressures can be individually set.
- The TCM Timer Counter Module allows periodic sigh (hyperinflation) breaths to minimize edema formation.
- An adapter to supply the trachea with a gas mixture different than room air during negative ventilation can be added.
Negative Pressure Ventilation Control Option with Pump for IPL-1 (73-4279) includes: |
Negative PressureVentilation Control Option with Pressure Regulator for IPL-1 (73-4293) includes: Utilizes 6 slot units |
||
Item # | Product Name | Item # | Product Name |
73-1741 | PLUGSYS Ventilation Control Module with Integral Pump(VCM-P) | 73-2795 | PLUGSYS Ventilation Control Module with Regulator(VCM-R)* |
73-1750 | PLUGSYS Time Counter Module (TCM) | 73-1750 | PLUGSYS Time Counter Module (TCM) |
N/A | See above | 73-2789 | Pressure-Free Gas SupplyAdapter for Alternative GasSupply** |
* Negative pressure ventilation with a pressure regulator (73-4293) built into the VCM-R requires a pressurized gas supply from a tank or house air in the range of 2 to 8 bar (29 to 116 PSI).
** The Pressure-Free Gas Supply Adapter (73-2789) is only for use during sub-atmospheric pressure ventilation with either the VCM-P or VCM-Rand is used to supply alternative gas mixtures to the lungs.
Positive Pressure Ventilation Only
If only positive pressure ventilation will be used, choose an option below.
- Ventilation rate from 60 to 400 breaths per minute.
- Stroke volume 30 to 350 µl, simple adjustment while running.
- Compact size allows positioning close to system for minimal system volume.
Positive PressureVentilation Option, 230 V (73-4305) includes: | Positive PressureVentilation Option, 115 V (73-4306) includes: | ||
Item # | Product Name | Item # | Product Name |
73-0044 | Mouse Ventilator MiniVent Type 845, 230 V | 73-0043 | Mouse Ventilator MinVent Type 845, 115 V |
73-2792 | Y-Adapter to Connect External Respirator to IPL-1 | 73-2792 | Y-Adapter to Connect External Respirator to IPL-1 |