For a functional unit the core system requires a suitable ventilation system. For only positive ventilation a mouse ventilator can be used. If positive and sub-atmospheric pressure ventilation are required, the Ventilation Control Module must be purchased.

Item# Description U.S. List Price Quantity
73-4279 Negative Pressure Ventilation Control Option with Pump for IPL-1 and IPL-2
73-4293 Negative Pressure Ventilation Control Option with Pressure Regulator for IPL-1 and IPL-2
73-4305 Positive Pressure Ventilation Option for IPL-1, 230 V
73-4306 Positive Pressure Ventilation Option for IPL-1, 115 V
73-2789 IPL-1 Gas Inlet Adapter, including needle valve
73-2919 Multi-Gas Inlet Adapter and stand to connect Aerosol Nebulizer and MicroVent, MiniVent or MidiVent
Login for U.S. Pricing


For a functional unit the core system requires a suitable ventilation system. For only positive ventilation a mouse ventilator can be used. If positive and sub-atmospheric pressure ventilation are required, the Ventilation Control Module must be purchased.

Positive and Sub-Atmospheric (Negative) Pressure Ventilation with Ventilation Control Module (VCM)

  • Used to control the ventilation of the isolated lung preparation. Allows for the physiological negative pressure ventilation of the lung and positive ventilation during preparation.
  • 30 to 100 breaths per minute.
  • I:E ratio can be set between 10 and 90% in 10% steps.
  • End-inspiratory, end-expiratory, sigh, positive and negative pressures can be individually set.
  • The TCM Timer Counter Module allows periodic sigh (hyperinflation) breaths to minimize edema formation.
  • An adapter to supply the trachea with a gas mixture different than room air during negative ventilation can be added.

Negative Pressure Ventilation Control Option with Pump for IPL-1 (73-4279) includes:
Utilizes 6 slot units

Negative PressureVentilation Control Option with Pressure Regulator for IPL-1 (73-4293) includes:
Utilizes 6 slot units
Item # Product Name Item # Product Name
73-1741  PLUGSYS Ventilation Control Module with Integral Pump(VCM-P) 73-2795  PLUGSYS Ventilation Control Module with Regulator(VCM-R)*
73-1750  PLUGSYS Time Counter Module (TCM) 73-1750  PLUGSYS Time Counter Module (TCM)
N/A  See above 73-2789  Pressure-Free Gas SupplyAdapter for Alternative GasSupply**

* Negative pressure ventilation with a pressure regulator (73-4293) built into the VCM-R requires a pressurized gas supply from a tank or house air in the range of 2 to 8 bar (29 to 116 PSI).

** The Pressure-Free Gas Supply Adapter (73-2789) is only for use during sub-atmospheric pressure ventilation with either the VCM-P or VCM-Rand is used to supply alternative gas mixtures to the lungs.

Positive Pressure Ventilation Only

If only positive pressure ventilation will be used, choose an option below.

  • Ventilation rate from 60 to 400 breaths per minute.
  • Stroke volume 30 to 350 µl, simple adjustment while running.
  • Compact size allows positioning close to system for minimal system volume.
 Positive PressureVentilation Option,230 V (73-4305) includes:   Positive PressureVentilation Option,115 V (73-4306) includes
Item # Product Name Item # Product Name
73-0044  Mouse Ventilator MiniVent Type 845, 230 V 73-0043  Mouse Ventilator MinVent Type 845, 115 V
73-2792  Y-Adapter to Connect External Respirator to IPL-1 73-2792  Y-Adapter to Connect External Respirator to IPL-1

 

 

Specifications