pH Control Option for IPL-1 and IPL-2

pH Control Module for IPL-2

This option controls and regulates the pH in the buffer solution by carefully bubbling it with CO2. Delivery of CO2 maintains pH when the system is not deoxygenated with a N2 /CO2 gas mixture.

Item# Description U.S. List Price Quantity
73-4308 pH Control Unit for IPL-1 System
73-4282 pH Control Option to IPL-2 Core System, 230 V
73-4283 pH Control Option to IPL-2 System, 115 V
Login for U.S. Pricing


This option controls and regulates the pH in the buffer solution by carefully bubbling it with CO2. Delivery of CO2 maintains pH when the system is not deoxygenated with a N2/CO2 gas mixture.

The pH is controlled by a feedback system which regulates CO2 gas bubbling into a dedicated small volume reservoir for minimizing foaming of perfusate. The pH is measured with a pH sensor. The pH control module (pHCM) allows setting to a desired pH, e.g. to 7.4.

A certain amount of CO2 is necessary to hold the pH constant in a physiological range. For example, in order to keep the pH in a buffer solution at 7.4 (e.g. in a Krebs-Henseleit buffer), 5% CO2 is necessary. If the measured pH is above this value (e.g. 7.4), a small valve opens so that CO2 from a tank goes to a frit in the reservoir. The CO2 changes the pH to a lower value. As soon the pH of 7.4 is reached the CO2 valve is closed. This acts in a closed loop and regulates the pH by bubbling with CO2. This is only necessary for perfusates which are CO2-dependent buffered.

Note: Available by special order for IPL-4. Please inquire.

Included Items

pH Control Unit for IPL-1 (73-4308) includes:
Item # Product Name
69-0072 Foodtrode™ Protein Resistant pH Electrode
69-0075 Protelyte™ Reference Electrolyte Solution, 100 ml
69-0077 Electrode Connecting Cable, BNC to AS7, 1 m (3.3 ft)
73-1784 BNC-BNC Connecting Cable
73-0215 PLUGSYS pH Measurement Module (pHMM)
73-1776 PLUGSYS pH Control Module (pHCM)
N/A Modified Cover to 0.5 L Reservoir

 

pH Control Unit for IPL-2, 230 V (73-4282) includes: pH Control Unit for IPL-2, 115 V (73-4283) includes:
Item # Product Name Item # Product Name
73-2269  Jacketed Glass Container for Isolated Lung*  73-2269  Jacketed Glass Container for Isolated Lung*
73-0114 REGLO Analog 4 Channel MS-4/8-100, 230 VAC, 50 Hz  73-0113  REGLO Analog 4 Channel MS-4/8-100, 115 VAC, 60 Hz
73-0155 3-Stop Tygon® E-Lab Tubing, 2.79 mm ID, 12/pack, Purple/White  73-0155  3-Stop Tygon® E-Lab Tubing, 2.79 mm ID, 12/pack, Purple/White
69-0072 Foodtrode™ Protein Resistant pH Electrode  69-0072  Foodtrode™ Protein Resistant pH Electrode
69-0075 Protelyte™ Reference Electrolyte Solution, 100 ml  69-0075  Protelyte™ Reference Electrolyte Solution, 100 ml
69-0077 Electrode Connecting Cable, BNC to AS7, 1 m (3.3 ft)  69-0077  Electrode Connecting Cable, BNC to AS7, 1 m (3.3 ft)
73-1784 BNC-BNC Connecting Cable  73-1784  BNC-BNC Connecting Cable
73-0215 PLUGSYS pH Measurement Module (pHMM)  73-0215  PLUGSYS pH Measurement Module (pHMM)
73-1776 PLUGSYS pH Control Module (pHCM)  73-1776  PLUGSYS pH Control Module (pHCM)
73-2811 Mixer for IPL-2 Buffer Reservoir  73-2811  Mixer for IPL-2 Buffer Reservoir


* With overflow to maintain constant perfusion solution level.

PLUGSYS moduels use a total of 4 slot units. Magnetic stirrer and stirbar sold separately