Working Heart Upgrade for IH-5 Core System
The IH-5 Langendorff System can be upgraded to a fully-ejecting working heart model for physiological cardiovascular studies, e.g., cardiac function and metabolism. The upgrade allows rapid and easy switching between working heart (ejecting heart) and Langendorff modes.
To upgrade an IH-5 Langendorff Core System to an IH-5 Working Heart System, add a Working Heart Upgrade and one of the species-specific atrial cannulae. To measure flow, a TTFM-2 flowmeter and species-suitable flow probe are also required.
To ensure that your system is properly configured as a complete setup that meets your experimental needs, please email us at sales@harvardapparatus.com or call us at 800-597-0580. In Europe, please call +49 7665 92000 or email sales@hugo-sachs.de. Upgrades can also be modified to meet your specific needs.
The IH-5 Langendorff System can be upgraded to a fully-ejecting working heart model for physiological cardiovascular studies, e.g., cardiac function and metabolism. The upgrade allows rapid and easy switching between working heart (ejecting heart) and Langendorff modes.
To upgrade an IH-5 Langendorff Core System to an IH-5 Working Heart System, add a Working Heart Upgrade and one of the species-specific atrial cannulae. To measure flow, a TTFM-2 flowmeter and species-suitable flow probe are also required.
Researchers who know they will be upgrading to working ejecting heart in the future typically start with a Langendorff Working Heart-Ready configuration. However, a Langendorff Only configuration can easily be modified to a Langendorff Working Heart-Ready configuration. Please contact our technical team for help!
Features & Benefits
Applications
Measured Signals & Calculated Parameters
Included Items
Species-Specific Additions
Specialized Applications & Upgrades
Features & Benefits
- Fully-ejecting working heart model for physiological cardiovascular studies, e.g. cardiac function and metabolism
- Allows rapid and easy switching between working heart (ejecting heart) and Langendorff modes.
Applications
- Real-time measurement of atrial and aortic flow (add species-appropriate flow probes and PLUGSYS TTFM-2 Flowmeter module)
- Intracardial left ventricular pressure (LVP) measurement (add LVP Measurement option)
- Pressure-volume measurement (add Pressure-Volume Loop Measurement option)
- High atrial pressure-induced disease state simulation (add Increased Preload Pressure option)
Measured Signals & Calculated Parameters
All parameters of standard Langendorff plus the following signals can be recorded:
- Preload (left atrial preload / ventricular filling pressure)
- Afterload (determining the diastolic and systolic aortic pressure)
- Left ventricular pressure or pressure-volume loops
- Cardiac output (atrial flow), aortic and coronatry flow (either Direct of by subtraction of CO-Aortic Flow)
Included Items
IH5-WH, Working Heart Upgrade, 230 V (73-4412) includes: |
IH5-WH Working Heart Upgrade, 115 V (73-4411) includes: |
||
73-3064 | Working Heart Option to IH-5 Core System* | 73-3064 | Working Heart Option to IH-5 Core System* |
73-0020 | Blood Pressure Transducer P75 for PLUGSYS Module | 73-0020 | Blood Pressure Transducer P75 for PLUGSYS Module |
73-0065 | PLUGSYS Transducer Amplifier Module (TAM-A) | 73-0065 | PLUGSYS Transducer Amplifier Module (TAM-A) |
73-0116 | Peristaltic Pump MCP-SB2, 230 V | 73-0115 | Peristaltic Pump MCP-SB2, 115 V |
The Working Heart Option (73-3064) includes:
Left atrium cannulating system with preload reservoir and preheating coil, movable atrium connection adapter and holder for P75 (preload pressure)
Peristaltic Pumps included are special packages suited for use with the IH-5:
73-0115 includes:
MC Pump Drive (73-3029), SB Pump Head (73-3040), 2 V Tube Bed Set (73-3045)
73-0116 includes:
MC Pump Drive (73-3026), SB Pump Head (73-3040), 2 V Tube Bed Set (73-3045)
Atrial Cannulae (Required, Purchase Separately)
Complete the Working Heart upgrade by choosing the appropriate species-specific addition:
73-4413 Working Heart Left Atrial Cannula for Rat/Guinea Pig Hearts, 2.3 mm OD
73-4414 Working Heart Left Atrial Cannula for Rabbit Hearts, 6.0 mm OD
Specialized Applications & Upgrades
Left Atrial and Aortic Flow Measurement Option
Flow measurement can be accomplished in an IH-SR unit using two methods:
- Indirect measurement by controlling the pump sped of a roller pump (SCP controller)
- Direct measurement with Ultrasound Transit Time Technic (TTFM-2 module)
Intracardial Left Ventricular Pressure (LVP) Measurement Option
Easily allows introduction of a tip pressure catheter directly into the left ventricle via the adapter port and the aorta, rather than via apical puncture.
Pressure-Volume Loop (PVL) Measurement Option
Easily allows introduction of a pressure-volume loop catheter directly into the left ventricle via an adapter port and the aorta.
Increased Preload Pressure Option
Choose this option when you need to create left atrial preload pressures higher than 11 mmHg. (Gottlieb Valve).
Coronary Effluent Collection Option
Pulmonary artery cannulae, preparation dish and effluent funnel for collectionof effluent from the coronaries for metabolic studies, further analysis, or for continuous pO2,pH, or pCO2 measurements.
For oxygenation of buffer solution supplemented with albumin, fatty acids, washed erythrocytes, or other foaming additives.
For filtration of recirculated perfusate.
Temperature Measurement Option
Measure perfusate temperature in any isolated perfused organ system. Since the system is well thermostated, temperature measurement is only necessary when specific temperature studies with special temperature protocols are being performed, e.g. cooling or transplantation studies.
Permits precise continuous or intermittent measurement in liquid media or perfusate of three key parameters: pO2, pH and pCO2.
These options for drug addition can be added to any isolated organ system where flow is measured or calculated and a drug must be added in a certain ratio.
For addition of pacing to functional IH-SR or IH-5 Langendorff and Working HeartSystems. For small rodent hearts (mouse, rat and guinea pig).
Single-Lead ECG and MAP Measurement
For single-lead ECG and MAP on functional IH-5 systems, one ECG lead is combined with one MAP electrode.
Multi-Lead ECG and MAP Measurement
For multi-lead ECG and MAP measurements on functional IH-5 Langendorff or workingheart systems, up to 12 ECG leads are combined with up to 8 MAP electrodes formeasurement on rat, guinea pig or rabbit hearts.