array(3) { ["show"]=> bool(true) ["ip"]=> string(13) "66.249.75.100" ["country"]=> string(2) "US" } desde la funcion de ip obtenemos IP invalida
harvardapparatus.com is a data controller for the purposes of the General Data Protection Regulation ("GDPR"). By proceeding to tick the consent box at right, you consent to harvardbioscience.com processing your personal data, under the GDPR and any other applicable legislation, that we collect from you in accordance with our Privacy Policy. If you wish to withdraw your consent for us to process your personal data please contact our Compliance Team. Please address any questions, comments and requests (including your right to withdraw your consent to process your personal data) regarding our data processing practices to our Compliance Team.
Allow

Single-Lead ECG and MAP Measurement for IH-SR and IH-5 Langendorff or Working Heart

Price on Request
SKU
GRP-Single-MAP

For single-lead ECG and MAP measurements on functional IH-SR or IH-5 Langendorff or working heart systems. ECG and MAP are recorded to be analyzed together.

The Monophasic Action Potential (MAP) electrodes work based on the principle of Franz et al whereby firm, stable contact of the MAP electrode results in a high-quality MAP. MAP recording has been utilized in cardiac physiology for decades as it allows regional assessment of the electrophysiological state of the intact heart.

For addiitonal options available for the IH-5 system, please see Multi-Lead ECG and MAP Measurement Options for IH-5 Langendorff or Working Heart.

Note: Images shown are representative.

Grouped product items
Item No. Description Qty
73-4025 Measurement of Single Epicardial Monophasic Action Potential on Mouse Heart Option Please login to add to Quote
73-4421 Measurement of Single Epicardial Monophasic Action Potential on Rat, Guinea Pig or Rabbit Heart Option Please login to add to Quote
73-4422 Measurement of ECG Lead II on Any IH System Option Please login to add to Quote
73-0150 Mini MAP-Tip Electrode for Rat, Guinea Pig and Rabbit Please login to add to Quote
73-0151 Holder for MAP Electrode for IH-SR System Please login to add to Quote
73-2910 Sponges for MAP Epicardial Probe Please login to add to Quote
73-2989 MAP Electrode Opposite Holder to Maintain Rat or Guinea Pig Heart in Position on IH-SR Please login to add to Quote
73-3840 Micro Map-Tip Electrode for Mouse Please login to add to Quote
73-3858 MAP Electrode Opposite Holder to Maintain Mouse Heart in Position on IH-SR Please login to add to Quote
73-0200 Contact ECG Electrode, Silver Chloride Pellet Please login to add to Quote
73-0174 Mini Ball Joint Holder, Eye-Eye, 23 mm long, pkg of 1 Please login to add to Quote
73-0177 Mini Ball Joint Holder, Eye-Ball, 23 mm long, pkg of 1 Please login to add to Quote

For single-lead ECG and MAP measurements on functional IH-SR or IH-5 systems, one ECG lead is combined with one MAP electrode.

The Monophasic Action Potential (MAP) electrodes work based on the principle of Franz et al* whereby firm, stable contact of the MAP electrode results in a high-quality MAP. MAP recording has been utilized in cardiac physiology for decades as it allows regional assessment of the electrophysiological state of the intact heart.

For additional options available for the IH-5 system, please see Multi-Lead ECG and MAP Measurement Options for IH-5 Langendorff or Working Heart.

* Franz MR, Burkhoff D, Spurgeon H, Weisfeldt ML, Lakatta EG (1986). In vitro validation of a new cardiac catheter technique for recording monophasic action potentials. Eur Heart J , 7: 34-41.


Features & Benefits

  • Mini monophasic action potential electrodes for epicardial and endocardial recording, with dedicated holders 
  • Precision MAP electrodes with dedicated holders allow easy positioning on the heart
  • Small electrodes allow multiple ECG and MAP signals to be recorded even on mouse hearts 
  •  Mini ECG electrodes with dedicated holders 
  •  Flexible ECG electrodes follow the heartbeat, dedicated holders allow easy positioning on the heart 
  •  Optimized coaxial pacing electrode 
  •  Reduced stray fields from the pacing electrode for more accurate recordings


Applications

MAP recording is essential to researchers who study:

  • Atrial fibrillation
  • Arrhythmias
  • Anti-arrhythmic drugs
  • Ischemia
  • Depolarization and repolarization cycles
  • Activation time
  • Mechanisms of action of various drugs


Options

For the addition of MAP recording to your functional isolated perfused heart system, we have a number of options:

Option Measurement Species System Compatibility Included Items
73-4025 Single Epicardial MAP Mouse IH-SR Micro MAP-tip electrode (73-3840)
Link for Higher Load Capacity, for Two Arms with 5 mm Mini Balls (73-0564)
MAP Opposite Holder to Maintain Mouse Heart in Position (73-3858)
Connection Cable for MAP Electrode to BPA Amplifier (73-0152)
PLUGSYS Biopotential Amplifier (BPA) Module (73-0153)
73-4026 Single Epicardial MAP Rat, Guinea Pig IH-SR Mini MAP-tip electrode (73-0150)
Holder for MAP Electrode for IH-SR System (73-0151)
MAP Opposite Holder to Maintain Rat or Guinea Pig Heart in Position (73-2989)
Connection Cable for MAP Electrode to BPA Amplifier (73-0152)
PLUGSYS Biopotential Amplifier (BPA) Module (73-0153)
73-4421 Single Epicardial MAP
Rat, Guinea Pig, Rabbit  IH-5 Mini MAP Tip Electrode (73-0150)
Link for Higher Load Capacity, for Two Arms with 5 mm Mini Balls (73-0564)
Mini Ball Joint Holder (73-0563)
Holders for MAP Electrode for Precise Placement and Stabilization (73-0151)
Large Opposite Holder (Spoon) for Larger Hearts for IH-5 (73-3755)
PLUGSYS Biopotential Amplifier (BPA) Module (73-0153)
Connection Cable for MAP Electrode to BPA Amplifier (73-0152)
73-4027 Single Endocardial MAP Rat, Guinea Pig, Rabbit  IH-SR, IH-5 Intracardial MAP-tip electrode with Holders (73-3715)
Connection Cable for MAP Electrode  to BPA Amplifier (73-0152)
PLUGSYS Biopotential Amplifier (BPA) Module (73-0153)
73-4422 ECG Lead II Mouse to Rabbit IH-SR, IH-5 Two Contact ECG Electrodes (73-0200)
Mini Ball Joint Holder System for Universal IH-System Mounting
ECG Amplifier
Connection Cable

MAP Electrodes

The MAP electrodes required for each application, species and system are included in the options above.

Micro MAP-Tip Electrode (73-3840) for single epicardial MAP on IH-SR with mouse heart includes the electrode, spring wire and pack of sponges, as well a 2 mm male connector. The MAP electrode opposite holder (73-3858) needs to be attached with a certain pressure to the heart on the opposite side to hold the heart in position.

Mini MAP-Tip Electrode (73-0150) for single epicardial MAP on IH-SR (rat, guinea pig heart) or IH-5 (rat, guinea pig, rabbit heart) comes with two male connectors and includes one pack of sponges. The MAP electrode opposite holder (73-2989) holds the rat or guinea pig heart in place at a certain pressure.

MAP Electrode for Intracardial MAP (73-3715) for endocardial MAP on IH-SR or IH-5 (rat, guinea pig, rabbit heart) includes necessary holders.

For more details about these packages, please contact Technical Support.

Specifications73-017473-0177
Ball Joint Holder Length23 mm23 mm