harvardapparatus.com is a data controller for the purposes of the General Data Protection Regulation ("GDPR"). By proceeding to tick the consent box at right, you consent to harvardbioscience.com processing your personal data, under the GDPR and any other applicable legislation, that we collect from you in accordance with our Privacy Policy. If you wish to withdraw your consent for us to process your personal data please contact our Compliance Team. Please address any questions, comments and requests (including your right to withdraw your consent to process your personal data) regarding our data processing practices to our Compliance Team.
Allow

Lung Weight Measurement (Edema Balance) Option for IPL-2 or IPL-4

Price on Request
SKU
gp73-4635

The weight measurement-edema balance option can be added to an IPL-2 or IPL-4 core system for mouse, rat, guinea pig or rabbit lungs. It requires the the 73-4626 PLUGSYS EdemaBalance Module (EBM), which includes the sensor.

  • Continuously monitor and measure edema formation over time. 
  • Raw data is weight; calculated value is weight change over time (dW/dT). 
  • Assess vascular permeability by calculating the filtration coefficient derived from weight changes induced by increasing and decreasing perfusion pressure. 
  • Range of ±10 or ±22 g; displacement 23 m/gm. 
  • Measure changes of less than 20 mg.
Grouped product items
Item No. Description Qty
73-4626 EBM Edema Balance Module (EBM) with Sensor Please login to add to Quote
73-4604 HSE Weight Measurement System V.2 without Sensor for IPL-2, Range 0 to 22 g, Rat or Guinea Pig Lungs Please login to add to Quote
73-4710 HSE Weight Measurement System V.2 without Sensor for IPL-2, Range 0 to 10 g, for Mouse Lungs Please login to add to Quote
73-4709 HSE Weight Measurement System V.2 without Sensor for IPL-4, Range 0 to 80 g, for Rabbit Lungs Please login to add to Quote

The weight measurement-edema balance option can be added to an IPL-2 or IPL-4 core system for mouse, rat, guinea pig or rabbit lungs. It requires the the 73-4626 PLUGSYS EdemaBalance Module (EBM), which includes the sensor.

  • Continuously monitor and measure edema formation over time.
  • Raw data is weight; calculated value is weight change over time (dW/dT).
  • Assess vascular permeability by calculating the filtration coefficient derived from weight changes induced by increasing and decreasing perfusion pressure.
  • Range of ±10 or ±22 g; displacement 23 m/gm.
  • Measure changes of less than 20 mg.

Includes: HSE Weight Measurement Transducer integrated into an alternativelung chamber cover (lid). EBM module must be purchased separately.

  73-4604 73-4710 73-4709

Measurement Range 

0 to 22 g 0 to 10 g 0 to 80 g
Resolution  20 mg 20 mg