Thermocouple Monitoring Thermometers
These Thermometers are for use with Thermocouple Probes and Microprobes. The Thermometers monitor these Probes three times per second for fast response to temperature changes.
- Choice of one or three probe inputs
Follow this link for Thermocouple Probes and Microprobes.
Follow this link for Accessories.
These Thermometers are for use with Thermocouple Probes and Microprobes. The Thermometers monitor these Probes three times per second for fast response to temperature changes.
Two models of this Thermometer are available: a single probe input or three probe input. Both are powered by four ‘C’ cell batteries (supplied) and have an analog output jack and mating connector for connection to a chart recorder. The Cable is not supplied.
The Single-Probe Thermometer has a temperature range from 25° to 45°C readable in 0.1°C increments. It reads temperatures in Celsius only.
The Three-Probe Thermometer displays the temperature reading in either Celsius or Fahrenheit. It has a temperature range from -10° to +60°C (14° to 140°F) readable in 0.1°C (0.1°F) increments. Push buttons on the front of the Thermometer are used to select which probe temperature is displayed.
Calibration | Conforms to National Institute of Standards and Technology tables. Monograph 125 | |
Leakage Currents | <10 μA at 60 Hz; the instrument is isolated from ground and from mounting supports to withstand 5,000 volts; capacitance to ground is low to ensure compatibility with electrosurgical equipment | |
Safety Standards | Conforms to: NFPA #56A, Inhalation Anesthetics UL #544, 1972 ANSI/AAMI Safe Current Limits for Electronics Apparatus | |
Sensor(s) | Type “T” thermocouple, copper-constant | |
Input Socket(s) | Miniature “T” quick disconnect, copper-constant | |
Monitoring Thermometer | Single Probe | Three Probe |
Temperature Range | 25° to 45°C | -10° to +60°C |
;Resolution | 0.1°C | 0.1°C |
Accuracy (Instrument Only) | 0.1°C ±1 digit | 0.1°C ±1 digit at 25°C ambient |
LCD Display | 3-1/2 digits, 12.7 mm (0.5 in) high numerical display only | 3-1/2 digits, 18 mm (0.7 in) high displays °C |
Power Supply | 4 “C” cell batteries | 4 “C” cell batteries |
Battery Life | 1,200 hrs continuous | 2,000 hrs continuous |
Battery Warnings | Automatic 2-stagewarning indicator flahes when 8 hours of life remain; becomes continuous when batteries must be replaced | LO-BAT appears display when battery voltage is low but several hours oflife remain |
Faulty Probe or Input | Display reads “0” | INPUT appears on display |