array(3) { ["show"]=> bool(true) ["ip"]=> string(12) "83.99.151.64" ["country"]=> string(2) "LV" } desde la funcion de ip obtenemos IP invalida
harvardapparatus.com is a data controller for the purposes of the General Data Protection Regulation ("GDPR"). By proceeding to tick the consent box at right, you consent to harvardbioscience.com processing your personal data, under the GDPR and any other applicable legislation, that we collect from you in accordance with our Privacy Policy. If you wish to withdraw your consent for us to process your personal data please contact our Compliance Team. Please address any questions, comments and requests (including your right to withdraw your consent to process your personal data) regarding our data processing practices to our Compliance Team.
Allow

Remote Infusion Only PHD 22/2000 Syringe Pumps

Price on Request
SKU
9b5755dc

Note: The Harvard Apparatus PHD 22/2000 Advance Syringe Pump family will be discontinued in 2020. Our PHD ULTRA™ series of syringe pumps offer a superior touch-screen replacement for the PHD 22/2000 with improved accuracy and precision. The PHD ULTRA™ LCD color touch screen display and intuitive icon interface provide unparalleled ease of use so you can efficiently program simple to complex pumping methods without a PC. Please follow this link to see the comparable PHD ULTRA™ models.

The Harvard PHD 22/2000 Advance Syringe Pump family is our versatile legacy pump line.

This page lists the remote infusion only versions of this dynamic family. Harvard Apparatus also offers infuse/withdraw, programmable and remote models.

All pumps have RS-232 communications capabilities.

In addition, a multitude of syringe racks are available to hold 2, 4 or up to 10 syringes. A microliter syringe rack is also available for microliter applications. These remote versions are also available where the control box and pumping mechanism are separated by a 9.1 meter (30 foot) cable.

Please follow this link for syringe options.

Please follow this link for tubing and connector options.

Grouped product items
Item No. Description Qty
No options of this product are available.

Note: The Harvard Apparatus PHD 22/2000 Advance Syringe Pump family will be discontinued in 2020. Our PHD ULTRA™ series of syringe pumps offer a superior touch-screen replacement for the PHD 22/2000 with improved accuracy and precision. The PHD ULTRA™ LCD color touch screen display and intuitive icon interface provide unparalleled ease of use so you can efficiently program simple to complex pumping methods without a PC. Please follow this link to see the comparable PHD ULTRA™ models.

The PHD 22/2000 syringe pump series gives you the lowest flow rates ever, the highest accuracy, the smoothest flow, advanced programmability from the keypad and yet, is very easy to use.

  • High accuracy and precision 
  • Low flow rate 
  • Ultimate flexibility and versatility 
  • 2-year warranty 

Highest Accuracy and Precision
A welded steel chassis, machined Delrin™ components, upgraded guide rods, and advanced electronics give accuracy within 0.35% and reproducibility within 0.05%.

Lowest Flow Rates
A new micro stepping motor and control software give the lowest flow rates ever, down to 0.0001 µl/hour. It is also incredibly quiet so it won’t disturb your experimental subjects.

Versatility
There is a PHD 22/2000 syringe pump to meet every need, whether it be simple infusion, infusion and withdrawal, or programming capabilities. This page lists the remote infuse only version of this dynamic syringe pump family.This pump is suitable for applications that require high accuracy and low rates but, do not need to withdraw fluid and do not need programmability. Should you need withdrawal or program capabilities later on, the infusion only pump can be upgraded

Easy to Use
A bright, easy to read, two-line fluorescent display can be easily read from across the lab. A target volume key makes it easy to dispense a set volume. An ergonomic ‘Autolock’ release mechanism is easy for even small hands to operate and can never be left unlocked. The numerical keys utilize the familiar ‘telephone’ layout.

Upgrade
We offer pumps that can be upgraded. If you buy an infuse only pump and later decide you want programmability you can upgrade it. You pay a lot less than buying a whole new pump.

High Pressure Syringe Pumps
Every version of the PHD 22/2000 Pump is now available with a stronger motor that can provide more force. These pumps are ideal when working with viscous fluid or when driving multiple syringes. The standard force PHD 22/2000 series syringe pump delivers an average nominal force of 50 lbs. while the high power version delivers 66 lbs. If you require even greater force see the PHD 22/2000 HPSI or the Pump 4400 HPSI.

Please follow this link for syringe options.

Please follow this link for tubing and connector options.

Specifications70-210071-210070-210371-210370-210471-210470-210571-2105
# of Syringes226/106/104444
Accuracy±0.35%±0.35%±0.35%±0.35%±0.35%±0.35%±0.35%±0.35%
Average Linear Force50 lbs (23 kg)66 lbs (30 kg)50 lbs (23 kg)66 lbs (30 kg)50 lbs (23 kg)6650 lbs (23 kg)66 lbs (30 kg)
Cable Length English30 in30 in30 in30 in30 in3030 in30 in
Cable Length Metric9.1 cm9.1 cm9.1 cm9.1 cm9.1 cm9.19.1 cm9.1 kg
CommunicationsRS-232, TTLRS-232, TTLRS-232, TTLRS-232, TTLRS-232, TTLRS-232, TTLRS-232, TTLRS-232, TTL
Communications Level22222222
Depth English11 in11 in11 in11 in11 in1111 in11 in
Depth Metric27.9 cm27.9 cm27.9 cm27.9 cm27.9 cm27.927.9 cm27.9 cm
DisplayFluorescent, 2-line, 40 characterFluorescent, 2-line, 40 characterFluorescent, 2-line, 40 characterFluorescent, 2-line, 40 characterFluorescent, 2-line, 40 characterFluorescent, 2-line, 40 characterFluorescent, 2-line, 40 characterFluorescent, 2-line, 40 character
Flow Rate Maximum220.82 mm/min220.82 mm/min106.76 mm/min106.76 mm/min220.82 mm/min220.82 mm/min31.486 mm/min31.486 mm/min
Flow Rate Minimum0.0001 ul/hr0.0001 ul/hr0.0001 ul/hr0.0001 ul/hr0.1019 ul/hr0.1019 ul/hr0.0001 ul/hr0.0001 ul/hr
Height English6.3 in6.3 in6.3 in6.3 in6.3 in6.3 in6.3 in6.3 in
Height Metric15.9 cm15.9 cm15.9 cm15.9 cm15.9 cm15.9 cm15.9 cm15.9 cm
Infusion OnlyInfusion OnlyInfusion OnlyInfusion OnlyInfusion OnlyInfusion OnlyInfusion OnlyInfusion OnlyInfusion Only
Input Power0.5 A, 65 W0.5 A, 65 W0.5 A, 65 W0.5 A, 65 W0.5 A, 65 W0.5 A, 65 W0.5 A, 65 W0.5 A, 65 W
Motor1/2 to 1/32 microstepping, microprocessor controlled, 1.81/2 to 1/32 microstepping, microprocessor controlled, 1.81/2 to 1/32 microstepping, microprocessor controlled, 1.81/2 to 1/32 microstepping, microprocessor controlled, 1.81/2 to 1/32 microstepping, microprocessor controlled, 1.81/2 to 1/32 microstepping, microprocessor controlled, 1.81/2 to 1/32 microstepping, microprocessor controlled, 1.81/2 to 1/32 microstepping, microprocessor controlled, 1.8
Motor Stepper 1 Revolution of Lead Screw800 at 1/2 stepping to 12,800 at 1/32 stepping800 at 1/2 stepping to 12,800 at 1/32 stepping800 at 1/2 stepping to 12,800 at 1/32 stepping800 at 1/2 stepping to 12,800 at 1/32 stepping800 at 1/2 stepping to 12,800 at 1/32 stepping800 at 1/2 stepping to 12,800 at 1/32 stepping800 at 1/2 stepping to 12,800 at 1/32 stepping800 at 1/2 stepping to 12,800 at 1/32 stepping
Net Weight English10 lbs10 lbs10 lbs10 lbs10 lbs10 lbs10 lbs10 lbs
Net Weight Metric4.5 kg4.5 kg4.5 kg4.5 kg4.5 kg4.5 kg4.5 kg4.5 kg
Non Volatile MemoryStorage of all settingsStorage of all settingsStorage of all settingsStorage of all settingsStorage of all settingsStorage of all settingsStorage of all settingsStorage of all settings
PressureStandardMediumStandardMediumStandardMediumStandardMedium
Pump ConfigurationRemoteRemoteRemoteRemoteRemoteRemoteRemoteRemote
Pusher Travel Rate Maximum190.676 mm/min190.676 mm/min190.676 mm/min190.676 mm/min190.676 mm/min190.676 mm/min190.676 mm/min190.676 mm/min
Pusher Travel Rate Minimum0.18 um/min0.18 um/min0.18 um/min0.18 um/min0.18 ul/min0.18 um/min0.18 um/min0.18 um/min
RS-232RJ11-4 ConnectorRJ11-4 ConnectorRJ11-4 ConnectorRJ11-4 ConnectorRJ11-4 ConnectorRJ11-4 ConnectorRJ11-4 ConnectorRJ11-4 Connector
Step Rate Maximum416.7 usec/step416.7 usec/step416.7 usec/step416.7 usec/step416.7 usec/step416.7416.7 usec/step416.7
Step Rate Minimum27.3 sec/step27.3 sec/step27.3 sec/step27.3 sec/step27.3 sec/step27.327.3 sec/step27.3
Step Resolution0.082 um/step0.082 um/step0.082 um/step0.082 um/step0.082 um/step0.082 um/step0.082 um/step0.082
Syringe Rack TypeStandard RackStandard Rack6/10 Multi-Syringe Rack6/10 Multi-Syringe Rack4 x 140 ml Syringe Rack4 x 140 ml Syringe RackMicroliter Syringe RackMicroliter Syringe Rack
Syringe Size Maximum140 ml140 ml60 ml60 ml140 ml140 ml10 ml10 ml
Syringe Size Minimum0.5 ul0.5 ul0.5 ul0.5 ul100 ml100 ml0.5 u;0.5 ul
TTL9-pin connector D-sub.9-pin connector D-sub.9-pin connector D-sub.9-pin connector D-sub.9-pin connector D-sub.9-pin connector D-sub.9-pin connector D-sub.9-pin connector D-sub.
TypeMicroprocessor multiple syringe, infusion only or infuse/withdraw, some models programmable from keypadMicroprocessor multiple syringe, infusion only or infuse/withdraw, some models programmable from keypadMicroprocessor multiple syringe, infusion only or infuse/withdraw, some models programmable from keypadMicroprocessor multiple syringe, infusion only or infuse/withdraw, some models programmable from keypadMicroprocessor multiple syringe, infusion only or infuse/withdraw, some models programmable from keypadMicroprocessor multiple syringe, infusion only or infuse/withdraw, some models programmable from keypadMicroprocessor multiple syringe, infusion only or infuse/withdraw, some models programmable from keypadMicroprocessor multiple syringe, infusion only or infuse/withdraw, some models programmable from keypad
Voltage RangeSelectable, 95 to 130 VAC, 60 Hz or 220 to 260 VAC, 50 HzSelectable, 95 to 130 VAC, 60 Hz or 220 to 260 VAC, 50 HzSelectable, 95 to 130 VAC, 60 Hz or 220 to 260 VAC, 50 HzSelectable, 95 to 130 VAC, 60 Hz or 220 to 260 VAC, 50 HzSelectable, 95 to 130 VAC, 60 Hz or 220 to 260 VAC, 50 HzSelectable, 95 to 130 VAC, 60 Hz or 220 to 260 VAC, 50 HzSelectable, 95 to 130 VAC, 60 Hz or 220 to 260 VAC, 50 HzSelectable, 95 to 130 VAC, 60 Hz or 220 to 260 VAC, 50 Hz
Width English9 in9 in9 in 9 in9 in9 in9 in9 in
Width Metric22.8 cm22.8 cm22.8 cm22.8 cm22.8 cm22.8 cm22.8 cm22.8 cm

Maaya Ikeda, Michelle A. Rensel, Barney A. Schlinger & Luke Remage-Healey (2014 ) In Vivo Detection of Fluctuating Brain Steroid Levels in Zebra Finches Cold Spring Harbor Protocols

Andreas Frutiger, Joseph T. Muth, Daniel M. Vogt, Yiǧit Mengüç, Alexandre Campo, Alexander D. Valentine, Conor J. Walsh & Jennifer A. Lewis (2015 ) Capacitive Soft Strain Sensors via Multicore–Shell Fiber Printing Advanced Materials

Jinhong Guo, Chang Ming Li & Yuejun Kang (2014 ) PDMS-film coated on PCB for AC impedance sensing of biological cells Biomedical Microdevices

Thibault Donnet, Catherine Ravanat, Anita Eckly, Eric Maurer, Ghina Alame, Catherine Ziessel, Pierre H. Mangin, Monique Freund, Jean-Pierre Cazenave, Christian Gachet & Francine Rendu (2015 ) Dehydration of blood platelets by zeodration: in vitro characterization and hemostatic properties in vivo Transfusion

Donghua Liao, Anne Lund Krarup, Flemming Holbæk Lundager, Asbjørn Mohr Drewes & Hans Gregersen (2014 ) Quantitative Differences Between Primary and Secondary Peristaltic Contractions of the Esophagus Digestive Diseases and Sciences

Keunhwan Park, Wonjung Kimb & Ho-Young Kim (2014 ) Optimal lamellar arrangement in fish gills PNAS (Proceedings of the National Academy of Sciences)

Wu Liu , Niejun Wang , Xuexia Lin , Yuan Ma & Jin-Ming Lin (2014 ) Interfacing Microsampling Droplets and Mass Spectrometry by Paper Spray Ionization for Online Chemical Monitoring of Cell Culture Analytical Chemistry

Shi-hui Chenm Li-zhen Zheng, Xin-hui Xie, Xin-luan Wanga, Yu-xiao Lai, Shu-kui Chen, Ming Zhang, Yi-xiang Wang, James F. Griffith & Ling Qin (2014 ) Comparative study of poly (lactic-co-glycolic acid)/tricalcium phosphate scaffolds incorporated or coated with osteogenic growth factors for enhancement of bone regeneration Journal of Orthopaedic Translation

Elisabeth Ehler & Suwan N. Jayasinghe (2014 ) Cell electrospinning cardiac patches for tissue engineering the heart Analyst

Mateusz Schabikowski, Justyna Tomaszewska, Dariusz Kata, Thomas Graule1 (2014 ) Rotary jet-spinning of hematite fibers Textile Research Journal

Davor Valinger, Ana Vrsalović Presečki, Želimir Kurtanjek, Martina Pohl, Zvjezdana Findrik Blažević & Đurđa Vasić-Račkib (2014 ) Continuous enzymatic carboligation of benzaldehyde and acetaldehyde in an enzyme ultrafiltration membrane reactor and laminar flow microreactors Journal of Molecular Catalysis B: Enzymatic

Nan Li, Miguel F. Diaz & Pamela L. Wenzel Ph.D. (2014 ) Application of Fluid Mechanical Force to Embryonic Sources of Hemogenic Endothelium and Hematopoietic Stem Cells Stem Cell Renewal and Cell-Cell Communication

Israfil Kucuk & Mohan Edirisinghe (2014 ) Microfluidic preparation of polymer nanospheres Journal of Nanoparticle Research

Michael E. Lacey , Z. Jessica Tan , Andrew G. Webb , Jonathan V. Sweedler (2001 ) Union of capillary high-performance liquid chromatography and microcoil nuclear magnetic resonance spectroscopy applied to the separation and identification of terpenoids Journal of Chromatography

Noah E. Robinson and Arthur B. Robinson (2000 ) Molecular Clocks PNAS (Proceedings of the National Academy of Sciences)

Rebecca J. Whelan, Thorsten Wohland, Lars Neumann, Bo Huang, Brian K. Kobilka and Richard N. Zare (2002 ) Analysis of Biomolecular Interactions Using a Miniaturized Surface Plasmon Resonance Sensor Analytical Chemistry

Hideyuki Ando, Yuki Nishio, Katsuki Ito, Akimasa Nakao, Li Wang, Ying Lan Zhao, Kiyoyuki Kitaichi, Kenzo Takagi and Takaaki Hasegawa (2001 ) Effect of Endotoxin on P-Glycoprotein-Mediated Biliary and Renal Excretion of Rhodamine-123 in Rats Antimicrobal Agents and Chemotherapy

Liu, R.H.; Stremler, M.A.; Sharp, K.V.; Olsen, Michael G. (2000 ) Passive mixing in a three-dimensional serpentine microchannel Journal of Micromechanical Systems

Diekamp, B.; Kalt, T.; Ruhm, A.; Koch, M.; Güntürkün, O. (2000) Impairment in a discrimination reversal task after D1 receptor blockade in the pigeon "prefrontal cortex". American Psychological Association

Hanbin Mao, Tinglu Yang, and Paul S. Cremer (2001 ) A Microfluidic Device with a Linear Temperature Gradient for Parallel and Combinatorial Measurements Journal of the American Chemical Society