array(3) { ["show"]=> bool(true) ["ip"]=> string(11) "57.141.0.22" ["country"]=> string(2) "US" } desde la funcion de ip obtenemos IP invalida
harvardapparatus.com is a data controller for the purposes of the General Data Protection Regulation ("GDPR"). By proceeding to tick the consent box at right, you consent to harvardbioscience.com processing your personal data, under the GDPR and any other applicable legislation, that we collect from you in accordance with our Privacy Policy. If you wish to withdraw your consent for us to process your personal data please contact our Compliance Team. Please address any questions, comments and requests (including your right to withdraw your consent to process your personal data) regarding our data processing practices to our Compliance Team.
Allow

Sterile Disposable Pressure Transducer (DTXPlus)

Price on Request
SKU
GRP-72-4293

Minimize distortion in the pressure waveform and maximize accuracy.

  • Individually packaged, sterile, disposable blood pressure transducers
  • Five-year shelf life
  • Stopcocks must be purchased separately
  • Class III according to European Medical Devices Directive 93/42/EEC
Grouped product items
Item No. Description Qty
72-4297 DTXPlus Sterile Disposable Single-Use Transducer, pkg. of 10, with Hugo-Sachs PLUGSYS Interface Cable Please login to add to Quote
72-4292 Replacement DTXPlus Disposable Single-Use BP Transducer, pkg. of 10 (Interface Cable not included) Please login to add to Quote
72-2883 Interface Cable, 12 ft (3.7 m), Universal Connector to Tinned Leads (no connector), For Use with Other Equipment, Mating Connector Required Please login to add to Quote
73-4479 Manual Pressure Calibrator, Range 0-300 mmHg Please login to add to Quote

DTXPlus blood pressure transducers minimize distortion in the pressure waveform and maximize accuracy.

  • Individually packaged, sterile, disposable blood pressure transducers
  • Five-year shelf life
  • Stopcocks must be purchased separately
  • Class III according to European Medical Devices Directive 93/42/EEC
Transducer Item # Interface Cable
72-4293 HAI
72-4297 PUGSYS TAM
72-4294 Grass Amplifiers
72-4295 PROPAQ
Pressure Range -30 to +300 mmHg
Over Pressure Tolerance -700 to +7,800 mm
Frequency Response >1,200 Hz, 15 bandwidth shall be >200 Hz
Transducer Excitation 1 to 10 V RMS
Transducer Excitation
Input Impedance 

1,100 to 3,450 Ω
Transducer Signal
Output Impedance
270 to 330 Ω
Nominal Sensitivity (gain) 5 µV/V/mmHg
Unbalance (Zero Balance) ±40 mmHg
Accuracy 2% of the reading or ±1 mmHg, whichever is
greater over the operating range
Operating Temperature 15° to 40°C