Membranes for Fast Micro-Equilibrium Dialyzers

Membranes for Fast Micro-Equilibrium Dialyzers

Available in MWCO’s from 500 Da to 300 kDa. Choose from regenerated cellulose, cellulose acetate or polycarbonate. Precut for the Fast Micro-Equilibrium Dialyzer .

Item# Description U.S. List Price Quantity
7416-RC1K Regenerated Cellulose Membranes, 1 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7415-RC1K Regenerated Cellulose Membranes, 1 kDa MWCO, 250 to 1500 µl Chamber Volumes, Qty. of 25
7416-RC2K Regenerated Cellulose Membranes, 2 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7415-RC2K Regenerated Cellulose Membranes, 2 kDa MWCO, 250 to 1500 µl Chamber Volumes, Qty. of 25
7416-RC3.5K Regenerated Cellulose Membranes, 3.5 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7415-RC3.5K Regenerated Cellulose Membranes, 3.5 kDa MWCO, 250 to 1500 µl Chamber Volumes, Qty. of 25
7416-RC10K Regenerated Cellulose Membranes, 10 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7415-RC10K Regenerated Cellulose Membranes, 10 kDa MWCO, 250 to 1500 µl Chamber Volumes, Qty. of 25
7416-RC25K Regenerated Cellulose Membranes, 25 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7415-RC25K Regenerated Cellulose Membranes, 25 kDa MWCO, 250 to 1500 µl Chamber Volumes, Qty. of 25
7416-RC50K Regenerated Cellulose Membranes, 50 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7415-RC50K Regenerated Cellulose Membranes, 50 kDa MWCO, 250 to 1500 µl Chamber Volumes, Qty. of 25
7416-CA500 Cellulose Acetate Membranes, 500 Da MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7415-CA500 Cellulose Acetate Membranes, 500 Da MWCO, 250 to 1500 µl Chamber Volumes, Qty. of 25
7416-CA1K Cellulose Acetate Membranes,1 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7415-CA1K Cellulose Acetate Membranes, 1 kDa MWCO, 250 to 1500 µl Chamber Volumes, Qty. of 25
7416-CA2K Cellulose Acetate Membranes, 2 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7415-CA2K Cellulose Acetate Membranes, 2 kDa MWCO, 250 to 1500 µl Chamber Volumes, Qty. of 25
7416-CA5K Cellulose Acetate Membranes, 5 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7415-CA5K Cellulose Acetate Membranes, 5 kDa MWCO, 250 to 1500 µl Chamber Volumes, Qty. of 25
7416-CA10K Cellulose Acetate Membranes,10 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7415-CA10K Cellulose Acetate Membranes, 10 kDa MWCO, 250 to 1500 µl Chamber Volumes, Qty. of 25
7416-CA25K Cellulose Acetate Membranes, 25 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7415-CA25K Cellulose Acetate Membranes, 25 kDa MWCO, 250 to 1500 µl Chamber Volumes, Qty. of 25
7416-CA50K Cellulose Acetate Membranes, 50 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7415-CA50K Cellulose Acetate Membranes, 50 kDa MWCO, 250 to 1500 µl Chamber Volumes, Qty. of 25
7416-CA100K Cellulose Acetate Membranes,100 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7416-CA300K Cellulose Acetate Membranes, 300 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7415-CA300K Cellulose Acetate Membranes, 300 kDa MWCO, 250 to 1500 µl Chamber Volumes, Qty. of 25
7416-PC01 Polycarbonate Membranes, 0.01 µm Pore Size, 25 to 250 µl Chamber Volumes, Qty. of 25
7415-PC01 Polycarbonate Membranes, 0.01 µm Pore Size, 250 to 1500 µl Chamber Volumes, Qty. of 25
7416-PC05 Polycarbonate Membranes, 0.05 µm Pore Size, 25 to 250 µl Chamber Volumes, Qty. of 25
7415-PC05 Polycarbonate Membranes, 0.05 µm Pore Size, 250 to 1500 µl Chamber Volumes, Qty. of 25
7416-PC10 Polycarbonate Membranes, 0.10 µm Pore Size, 25 to 250 µl Chamber Volumes, Qty. of 25
7415-PC10 Polycarbonate Membranes, 0.10 µm Pore Size, 250 to 1500 µl Chamber Volumes, Qty. of 25
7416-PC60 Polycarbonate Membranes, 0.60 µm Pore Size, 25 to 250 µl Chamber Volumes, Qty. of 25
7415-PC60 Polycarbonate Membranes, 0.60 µm Pore Size, 250 to 1500 µl Chamber Volumes, Qty. of 25
Login for U.S. Pricing


Membranes for the Fast Micro-Equilibrium Dialyzer are available in three different materials to suit your application. 

Regenerated Cellulose: Constructed of a very stable cellulose, these membranes are resistant to solvents and inert to proteins, providing maximum sample retention. Available in MWCO’s from 1-50 kDa, they have less defined pore sizes than the Cellulose Acetate Membranes.

Cellulose Acetate: Made of rayon and ideal for use with aqueous solutions, these membranes are inert to proteins providing high sample retention. They are not meant for use with any organic solvents. Available in MWCO’s from 500 Da – 300 kDa, they have a more defined pore size than the Regenerated Cellulose Membranes.

Polycarbonate Membrane: Chemically resistant and ideal for use with acids and organic solvents, Polycarbonate Membranes are available with sharply defined pore sizes ranging from 0.01 µm – 0.60 µm.  

Membranes ship dry to increase their shelf life. Membranes must be rehydrated before use.

Specifications