Membranes for ElectroPrep Primary Link Chambers

Membranes for ElectroPrep Primary Link Chambers

The Membranes for ElectroPrep Primary Link Chambers are available in regenerated cellulose and celluose acetate membranes in MWCO’s ranging from 500 Da to 300 kDa, and in polycarbonate with pore sizes from 0.01 to 0.60 µm pore size. Membranes are 11/16” in diameter and precut to fit ElectroPrep primary link chambers.

Item# Description U.S. List Price Quantity
7416-RC1K Regenerated Cellulose Membranes, 1 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7425-RC1K Regenerated Cellulose Membrane, 1 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25
7416-RC2K Regenerated Cellulose Membranes, 2 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7425-RC2K Regenerated Cellulose Membrane, 2 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25
7425-RC3.5K Regenerated Cellulose Membrane, 3.5 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25
7416-RC3.5K Regenerated Cellulose Membranes, 3.5 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7425-RC10K Regenerated Cellulose Membrane, 10 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25
7416-RC25K Regenerated Cellulose Membranes, 25 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7425-RC25K Regenerated Cellulose Membrane, 25 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25
7416-RC50K Regenerated Cellulose Membranes, 50 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7425-RC50K Regenerated Cellulose Membrane, 50 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25
7416-CA1K Cellulose Acetate Membranes,1 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7425-CA1K Cellulose Acetate Membrane, 1 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25
7416-CA2K Cellulose Acetate Membranes, 2 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7425-CA2K Cellulose Acetate Membrane, 2 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25
7416-CA5K Cellulose Acetate Membranes, 5 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7425-CA5K Cellulose Acetate Membrane, 5 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25
7416-CA10K Cellulose Acetate Membranes,10 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7425-CA10K Cellulose Acetate Membrane, 10 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25
7416-CA25K Cellulose Acetate Membranes, 25 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7425-CA25K Cellulose Acetate Membrane, 25 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25
7416-CA50K Cellulose Acetate Membranes, 50 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7425-CA50K Cellulose Acetate Membrane, 50 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25
7416-CA100K Cellulose Acetate Membranes,100 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7425-CA100K Cellulose Acetate Membrane, 100 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25
7416-CA300K Cellulose Acetate Membranes, 300 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25
7425-CA300K Cellulose Acetate Membrane, 300 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25
7416-PC01 Polycarbonate Membranes, 0.01 µm Pore Size, 25 to 250 µl Chamber Volumes, Qty. of 25
7425-PC01 Polycarbonate Membrane, 0.01 µm Pore Size, 500 to 1500 µl, Qty. of 25
7416-PC05 Polycarbonate Membranes, 0.05 µm Pore Size, 25 to 250 µl Chamber Volumes, Qty. of 25
7425-PC05 Polycarbonate Membrane, 0.05 µm Pore Size, 500 to 1500 µl, Qty. of 25
7416-PC10 Polycarbonate Membranes, 0.10 µm Pore Size, 25 to 250 µl Chamber Volumes, Qty. of 25
7425-PC10 Polycarbonate Membrane, 0.10 µm Pore Size, 500 to 1500 µl, Qty. of 25
7416-PC60 Polycarbonate Membranes, 0.60 µm Pore Size, 25 to 250 µl Chamber Volumes, Qty. of 25
7425-PC60 Polycarbonate Membrane, 0.60 µm Pore Size, 500 to 1500 µl, Qty. of 25
Login for U.S. Pricing


The Membranes for ElectroPrep Primary Link Chambers are available in regenerated cellulose and celluose acetate membranes in MWCO’s ranging from 500 Da to 300 kDa, and in polycarbonate with pore sizes from 0.01 to 0.60 µm pore size. Membranes are 11/16” in diameter and precut to fit ElectroPrep primary link chambers.

Regenerated Cellulose: Constructed of a very stable cellulose, regenerated cellulose membranes are resistant to solvents. This membrane is inert to proteins providing maximum sample retention. These membranes are available in MWCO’s from 1 to 50 kDa with pore sizes that are less defined than the cellulose acetate membranes.

Cellulose Acetate: Cellulose Acetate membranes are made of rayon and are ideal for use with aqueous solutions. They are not meant for use with any organic solvents. These membranes are inert to proteins providing high sample retention. These membranes are available in MWCO’s from 500 Da to 300 kDa and have a more defined pore size than the regenerated cellulose membranes.

Polycarbonate Membrane: Polycarbonate membranes are chemically resistant and are ideal for use with acids and organic solvents. These membranes are available with sharply defined pore sizes ranging from 0.01 µm to 0.60 µm. Harvard Apparatus ships membranes dry to increase their shelf life. Membranes must be rehydrated before use.

Specifications