array(3) { ["show"]=> bool(true) ["ip"]=> string(13) "62.218.203.35" ["country"]=> string(2) "AT" } desde la funcion de ip obtenemos IP invalida
harvardapparatus.com is a data controller for the purposes of the General Data Protection Regulation ("GDPR"). By proceeding to tick the consent box at right, you consent to harvardbioscience.com processing your personal data, under the GDPR and any other applicable legislation, that we collect from you in accordance with our Privacy Policy. If you wish to withdraw your consent for us to process your personal data please contact our Compliance Team. Please address any questions, comments and requests (including your right to withdraw your consent to process your personal data) regarding our data processing practices to our Compliance Team.
Allow

Membranes for ElectroPrep Primary Link Chambers

Price on Request
SKU
GRP 7416-RC1K

The Membranes for ElectroPrep Primary Link Chambers are available in regenerated cellulose and celluose acetate membranes in MWCO’s ranging from 500 Da to 300 kDa, and in polycarbonate with pore sizes from 0.01 to 0.60 µm pore size. Membranes are 11/16” in diameter and precut to fit ElectroPrep primary link chambers.

Grouped product items
Item No. Description Qty
7416-RC1K Regenerated Cellulose Membranes, 1 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7425-RC1K Regenerated Cellulose Membrane, 1 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7416-RC2K Regenerated Cellulose Membranes, 2 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7425-RC2K Regenerated Cellulose Membrane, 2 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7425-RC3.5K Regenerated Cellulose Membrane, 3.5 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7416-RC3.5K Regenerated Cellulose Membranes, 3.5 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7425-RC10K Regenerated Cellulose Membrane, 10 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7416-RC25K Regenerated Cellulose Membranes, 25 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7425-RC25K Regenerated Cellulose Membrane, 25 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7416-RC50K Regenerated Cellulose Membranes, 50 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7425-RC50K Regenerated Cellulose Membrane, 50 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7416-CA1K Cellulose Acetate Membranes,1 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7425-CA1K Cellulose Acetate Membrane, 1 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7416-CA2K Cellulose Acetate Membranes, 2 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7425-CA2K Cellulose Acetate Membrane, 2 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7416-CA5K Cellulose Acetate Membranes, 5 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7425-CA5K Cellulose Acetate Membrane, 5 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7416-CA10K Cellulose Acetate Membranes,10 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7425-CA10K Cellulose Acetate Membrane, 10 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7416-CA25K Cellulose Acetate Membranes, 25 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7425-CA25K Cellulose Acetate Membrane, 25 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7416-CA50K Cellulose Acetate Membranes, 50 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7425-CA50K Cellulose Acetate Membrane, 50 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7416-CA100K Cellulose Acetate Membranes,100 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7425-CA100K Cellulose Acetate Membrane, 100 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7416-CA300K Cellulose Acetate Membranes, 300 kDa MWCO, 25 to 250 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7425-CA300K Cellulose Acetate Membrane, 300 kDa MWCO, 500 to 1500 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7416-PC01 Polycarbonate Membranes, 0.01 µm Pore Size, 25 to 250 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7425-PC01 Polycarbonate Membrane, 0.01 µm Pore Size, 500 to 1500 µl, Qty. of 25 Please login to add to Quote
7416-PC05 Polycarbonate Membranes, 0.05 µm Pore Size, 25 to 250 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7425-PC05 Polycarbonate Membrane, 0.05 µm Pore Size, 500 to 1500 µl, Qty. of 25 Please login to add to Quote
7416-PC10 Polycarbonate Membranes, 0.10 µm Pore Size, 25 to 250 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7425-PC10 Polycarbonate Membrane, 0.10 µm Pore Size, 500 to 1500 µl, Qty. of 25 Please login to add to Quote
7416-PC60 Polycarbonate Membranes, 0.60 µm Pore Size, 25 to 250 µl Chamber Volumes, Qty. of 25 Please login to add to Quote
7425-PC60 Polycarbonate Membrane, 0.60 µm Pore Size, 500 to 1500 µl, Qty. of 25 Please login to add to Quote

The Membranes for ElectroPrep Primary Link Chambers are available in regenerated cellulose and celluose acetate membranes in MWCO’s ranging from 500 Da to 300 kDa, and in polycarbonate with pore sizes from 0.01 to 0.60 µm pore size. Membranes are 11/16” in diameter and precut to fit ElectroPrep primary link chambers.

Regenerated Cellulose: Constructed of a very stable cellulose, regenerated cellulose membranes are resistant to solvents. This membrane is inert to proteins providing maximum sample retention. These membranes are available in MWCO’s from 1 to 50 kDa with pore sizes that are less defined than the cellulose acetate membranes.

Cellulose Acetate: Cellulose Acetate membranes are made of rayon and are ideal for use with aqueous solutions. They are not meant for use with any organic solvents. These membranes are inert to proteins providing high sample retention. These membranes are available in MWCO’s from 500 Da to 300 kDa and have a more defined pore size than the regenerated cellulose membranes.

Polycarbonate Membrane: Polycarbonate membranes are chemically resistant and are ideal for use with acids and organic solvents. These membranes are available with sharply defined pore sizes ranging from 0.01 µm to 0.60 µm. Harvard Apparatus ships membranes dry to increase their shelf life. Membranes must be rehydrated before use.