Reverse Phase Chromatography SpinColumns

Reverse Phase Chromatography Spin Columns

Reverse phase chromatography uses a spin column packed with a stationary non-polar phase, and a polar mobile phase is passed through the column. Molecules with similar polarities attract one another causing the most polar compounds to elute first as the non-polar compounds are held by the non-polar matrix These non-polar compounds can then be released through the addition of an elution buffer.

Item# Description U.S. List Price Quantity
74-7228 Ultra-Micro SpinColumn, C4, Pkg. 24
74-7208 Ultra-Micro SpinColumn, C4, Pkg. 96
74-7227 Ultra-Micro SpinColumn, C8, Pkg. 24
74-7207 Ultra-Micro SpinColumn, C8, Pkg. 96
74-7226 Ultra-Micro SpinColumn, C18, Pkg. 24
74-7206 Ultra-Micro SpinColumn, C18, Pkg. 96
74-4609 Micro SpinColumn, C4, Pkg. 24
74-4603 Micro SpinColumn, C4, Pkg. 96
74-4608 Micro SpinColumns, C8, Pkg. 24
74-4602 Micro SpinColumn, C8, Pkg. 96
74-4607 Micro SpinColumn, C18, Pkg. 24
74-4601 Micro SpinColumns, C18, Pkg. 96
74-4109 Macro SpinColumn, C4, Pkg. 24
74-4103 Macro SpinColumn, C4, Pkg. 96
74-4108 Macro SpinColumn, C8, Pkg. 24
74-4102 Macro SpinColumn, C8, Pkg. 96
74-4107 Macro SpinColumn, C18, Pkg. 24
74-4101 Macro SpinColumn, C18, Pkg. 96
74-5619 96-Well Micro SpinColumn, C4, 1 plate
74-5618 96-Well Micro SpinColumn, C8, 1 Plate
74-5617 96-Well Micro SpinColumn, C18, 1 plate
74-5637 96-Well Micro SpinColumn, C18 Targa, 1 plate
74-5659 96-Well Macro SpinColumns, C4, 1 Plate
74-5658 96-Well Macro SpinColumns, C8, 1 Plate
74-5657 96-Well Macro SpinColumns, C18, 1 Plate
Login for U.S. Pricing


Reverse phase chromatography uses a spin column packed with a stationary non-polar phase, and a polar mobile phase is passed through the column. Molecules with similar polarities attract one another causing the most polar compounds to elute first as the non-polar compounds are held by the non-polar matrix These non-polar compounds can then be released through the addition of an elution buffer.

Reverse phase matrixes include: C4, C8, C18 and C18 Targa

 

Ultra-Micro Spin Columns- 

Sample volumes: 10 μl - 25 μl.

Each column includes two 2 ml centrifuge tubes with top caps

 

Micro SpinColumns 

Sample Volumes: 25 - 75 μl.

Each column includes two 2 ml centrifuge tubes with top cap 

 

Macro SpinColumns 

Sample volumes: 75 - 150 μl.

Each column includes two 2 ml centrifuge tubes and top and bottom caps.

 

96-Well MicroSpin Columns

Sample Volumes: 25 - 75 μl

Includes two 96-Well collection plates (1.1 ml per well).

Additional 96-Well SpinColumns with 450 μl per well collection plates are available.

 

96-Well Macro SpinColumns-

Sample Volumes: 25 - 150 μl  

Includes two 96-Well collection plates (1.1 ml per well). 

Specifications