Pump 11 Elite Glucose Clamp Pumps

Pump 11 Elite Glucose Clamp Pumps

The Pump 11 Elite Glucose Clamp Infusion System, is a version of our renowned syringe pump technology enhanced for academic euglycemic or hyperglycemic glucose clamp studies.

The glucose clamp capabilities provide a time saving syringe pump enhancement that offers quick and simple set-up using our innovative touch screen display.

The built-in software capabilities reduce the potential for error in your research by providing the most accurate fluid delivery available.

The Pump 11 Elite Glucose Clamp Infusion System will simplify glucose clamp experiments with the following features.

1) Animal Weight, Concentration, and Dose Rate Programming

Glucose clamp method allows the user to enter in a desired concentration, animal weight, and dose rate in the syringe pump and then uses that information to set the infusion rate automatically.

2) Change Dose Rate While Running in the Glucose Clamp method

The user has the ability to change the dose rate during infusion. This allows the execution of complex infusion procedures without the need to start and stop the process.

3) Previous Dose Rate Display

The previous dose rate setting is displayed while the pump is running, which allows for easy monitoring. When the unit is stopped, the last dose rate set and its duration is clearly displayed.

Please follow this link for Delivery & Sampling accessories.

Please follow this link for syringe options.

Please follow this link for tubing and connector options.

Item# Description U.S. List Price Quantity
70-4504GC Pump 11 Elite Infusion/Withdrawal Programmable Single Syringe Pump with Glucose Clamp Method
70-4505GC Pump 11 Elite Infusion/Withdrawal Programmable Dual Syringe Pump with Glucose Clamp Method
70-4506GC Pump 11 Pico Plus Elite Infusion/Withdrawal Programmable Dual Syringe Pump with Glucose Clamp Method
70-4507GC Pump 11 Elite Nanomite Infusion/Withdrawal Programmable Single Syringe Pump with Glucose Clamp Method
70-4511GC Pump 11 Pico Plus Elite Infusion/Withdrawal Programmable Single Syringe Pump with Glucose Clamp Method
Login for U.S. Pricing


The Pump 11 Elite Glucose Clamp Infusion System, is a version of our renowned syringe pump technology enhanced for academic euglycemic or hyperglycemic glucose clamp studies.

The glucose clamp capabilities provide a time saving syringe pump enhancement that offers quick and simple set-up using our innovative touch screen display. The built-in software capabilities reduce the potential for error in your research by providing the most accurate fluid delivery available.


Features

  • Intuitive Touch Screen with Glucose Clamp software
  • Program animal weight, concentration and dose rate without a PC
  • Ability to change dose rate while running
  • Previous dose rate display to simplify data recording
  • Icon operation
  • New color LCD touch screen
  • Vertical or horizontal orientation
  • Adjustable linear force to 11 or 35 lbs (depending on model) across the entire flow range
  • CE, ETL (UL, CSA), WEEE, EU RoHS, CB Scheme Approved
  • 2-year warranty 

Applications

  • Euglycemic and hyperglycemic glucose clamp studies
  • Drug/Nutritional infusions

Simplfy Glucose Clamp Experiments

The Pump 11 Elite Glucose Clamp Infusion System will simplify glucose clamp experiments with the following capabilities:

1) Animal Weight, Concentration, and Dose Rate Programming

Glucose clamp method allows the user to enter in a desired concentration, animal weight, and dose rate in the syringe pump and then uses that information to set the infusion rate automatically.

2) Change Dose Rate While Running in the Glucose Clamp method

The user has the ability to change the dose rate during infusion. This allows the execution of complex infusion procedures without the need to start and stop the process.

3) Previous Dose Rate Display

The previous dose rate setting is displayed while the pump is running, which allows for easy monitoring. When the unit is stopped, the last dose rate set and its duration is clearly displayed.

Please follow this link for Delivery & Sampling accessories.

Please follow this link for syringe options.

Please follow this link for tubing and connector options.

Specifications70-4504GC70-4505GC70-4506GC70-4507GC70-4511GC
Accuracy±0.5%±0.5%±0.35%±0.5%±0.5%
Syringes122Class I1
Flow Rate Minimum1.26 pl/min1.26 pl/min0.54 pl/min9.0 x 7.0 x 3.67 in (22.6 x 17.78 x 9.32 cm)3.66 pl/min
Flow Rate Maximum88.4 ml/min26.02 ml/min11.7 ml/min2.5 x 2.0 x 7.5 in (6.35 x 5.08 x 19.05 cm)3.818 ml/min
ClassificationClass IClass IClass I 0.3125” (0.793 cm) ODClass I
Dimensions, Control Box
L x D x H
9.0 x 7.0 x 6.0 in (22.6 x 17.78 x 15.0 cm)9.0 x 7.0 x 6.0 in (22.6 x 17.78 x 15.0 cm)9.0 x 7.0 x 6.0 in (22.6 x 17.78 x 15.0 cm)3.25” (8.25 cm) 9.0 x 7.0 x 3.67 in (22.6 x 17.78 x 9.32 cm)
Dimensions, Remote Box
L x D x H
N/AN/AN/A4.3" WQVGA TFT Color Display with Touchpad2.5 x 2.0 x 7.5 in (6.35 x 5.08 x 19.05 cm)
Display4.3" WQVGA TFT Color Display with Touchpad4.3" WQVGA TFT Color Display with Touchpad4.3" WQVGA TFT Color Display with Touchpad1.8° Stepper Motor4.3" WQVGA TFT Color Display with Touchpad
Drive Motor0.9° Stepper Motor0.9° Stepper Motor0.9° Stepper Motor20% to 80% RH, non condensing1.8° Stepper Motor
Environmental Humidity20% to 80% RH, non condensing20% to 80% RH, non condensing20% to 80% RH, non condensing40°F to 104°F (4°C to 40°C)20% to 80% RH, non condensing
Environmental Operating Temperature40°F to 104°F (4°C to 40°C)40°F to 104°F (4°C to 40°C)40°F to 104°F (4°C to 40°C)14°F to 158°F (-10°C to 70°C)40°F to 104°F (4°C to 40°C)
Environmental Storage Temperature14°F to 158°F (-10°C to 70°C)14°F to 158°F (-10°C to 70°C)14°F to 158°F (-10°C to 70°C)3.818 ml/min using 1 ml syringe14°F to 158°F (-10°C to 70°C)
I O TTL Connectors15-pin D-Sub Connector15-pin D-Sub Connector15-pin D-Sub Connector3.66 pl/min using 0.5 µl syringe15-pin D-Sub Connector
Input Power12-30 VDC12-30 VDC12-30 VDC15-pin D-Sub Connector12-30 VDC
Installation CategoryIIIIII12-30 VDCII
Max Linear Force35 lb at 100% Force35 lb at 100% Force35 lb at 100% ForceII11 lb at 100% Force
Mode of OperationGlucose ClampGlucose ClampGlucose Clamp11 lb @ 100% Force SelectionGlucose Clamp
Motor Drive ControlMicroprocessor with 1/16 microsteppingMicroprocessor with 1/16 microsteppingMicroprocessor with 1/16 microsteppingContinuousMicroprocessor with 1/16 microstepping
Net Weight4.6 lb (2.1 kg)4.6 lb (2.1 kg)4.6 lb (2.1 kg)Microprocessor with 1/16 microstepping4.32 lb(1.96 kg)
No of Syringes1224.32 lb (1.96 kg)1
Non Volatile MemoryStorage of all settingsStorage of all settingsStorage of all settings1.01 lb (0.458 kg)Storage of all settings
Number of Microsteps per one rev of Lead Screw15,36015,36020,48013,200
Pollution Degree111Storage of all settings1
Pump ConfigurationSingleDualDual3,200Single
Pump FunctionInfuse/Withdraw, Programmable with Glucose Clamp MethodInfuse/Withdraw, Programmable with Glucose Clamp MethodInfuse/Withdraw, Programmable with Glucose Clamp Method1Infuse/Withdraw, Programmable with Glucose Clamp Method
Pusher Travel Rate Maximum159.8 mm/min159.8 mm/min71.55 mm/minRemote159.8 mm/min
Pusher Travel Rate Minimum0.18 µm/min0.18 µm/min0.068 µm/minInfuse/Withdraw, Programmable0.18 µm/min
Regulatory CertificationsCE, ETL (UL, CSA), WEEE, EU RoHS, CB SchemeCE, ETL (UL, CSA), WEEE, EU RoHS, CB SchemeCE, ETL (UL, CSA), WEEE, EU RoHS, CB Scheme228.97 mm/minCE, ETL (UL, CSA), WEEE, EU RoHS, CB Scheme
Step Rate Maximum26 µsec/26 µsec/26 µsec/0.433 µm/min52 µsec/
Step Rate Minimum27.5 sec/µstep27.5 sec/µstep27.5 sec/µstepoptional RJ-1127.5 sec/µstep
Syringe Size Maximum60 ml10 ml10 mlCE, ETL (UL, CSA), WEEE, EU RoHS & CB Scheme1 ml
Syringe Size Minimum0.5 µl0.5 µl0.5 µl52 µsec/µstep0.5 µl
USB ConnectorsType BType BType B27.5 sec/µstepType B
Voltage Range100-240 VAC, 50/60 Hz100-240 VAC, 50/60 Hz100-240 VAC, 50/60 HzStandard Rack100-240 VAC, 50/60 Hz

Shichun Du, Hui Wu, Xiao Xu, Ying Meng, Fangzhen Xia, Hualing Zhai & Yingli Lu (2014 ) Tracing Fasting Glucose Fluxes with Unstressed Catheter Approach in Streptozotocin Induced Diabetic Rats Journal of Diabetes Research

Hui Wu, Chunhua Sui, Hui Xu, Fangzhen Xia, Hualing Zhai, Huixin Zhang, Pan Weng, Bing Han, Sichun Du, and Yingli Lu (2014 ) The GLP-1 Analogue Exenatide Improves Hepatic and Muscle Insulin Sensitivity in Diabetic Rats: Tracer Studies in the Basal State and during Hyperinsulinemic-Euglycemic Clamp Journal of Diabetes Research

Qin Fu, Bing Xu, Yongming Liu, Dippal Parikh, Jing Li, Ying Li, Yuan Zhang, Christian Riehle, Yi Zhu, Tenley Rawlings, Qian Shi, Richard B. Clark, Xiongwen Chen, E. Dale Abel & Yang K. Xiang (2014 ) Insulin Inhibits Cardiac Contractility by Inducing a Gi-Biased β2-Adrenergic Signaling in Hearts Diabetes Journal

DOCUMENT DESCRIPTION
11 Elite Manual_5420-002REV1.0.pdfPump 11 Elite & Pump 11 Pico Plus Elite Manual
11 Elite Nanomite Manual_5420-006REV1.0.pdfPump 11 Elite Nanomite Manual
Glucose-Clamp -Addendum-5423-004REVB.pdf Pump 11 Elite Family Glucose Clamp Addendum
HA%20Pump%2011%20Elite%20GC_Brochure.pdf Pump 11 Elite Glucose Clamp Infusion System Brochure
Pump-11-Elite-Series-DoC.pdfPump 11 Elite Family: Declaration of Conformity