Harvard Apparatus Pump Controller (HAPC)
Precision infusion for accurate, reliable and repeatable results is critical to the success of your work. High experiment throughput is essential to keep up with your rapidly changing research area. When using fluidics in research, it can be difficult to know which solution will provide the most reliable and repeatable results, yet best supports high throughput and concurrent experiments.
What if you had a pump controller that would allow you to run multiple infusion experiments – simultaneously or independently, to accelerate experiment throughput without compromising accuracy? And what if that tool provided clear feedback on each experiment-in real time?
The Harvard Apparatus Pump Controller (HAPC) allows configuration and control of up to four pumping channels- independently or simultaneously, using an intuitive, touch screen interface. The HAPC delivers precise infusion and provides clear feedback on the status of each infusion—in real time, across all relevant infusion possibilities.
The HAPC offers preprogrammed flow methods for simple to complex operations that allow you to be up and running with the push of a button. You can even save your flow profiles on the HAPC and use them when needed.
Compatible with Harvard Apparatus Nanomite, PHD ULTRA™ and Pump 11 Elite/Pico Plus Elite stand-alone syringe pumps and syringe pump modules, the controller is easy to set up and easy to use. You can mix pump module types to build the perfect system for your application. The HAPC is an expandable system. Purchase a one, two or three channel system now and add channels as needed.
Choose a controller configuration, select your pumping mechanism and experience complete control over your fluidic experiments.
Infusion Efficiency with World Class Precision
Run up to four independent precision infusion experiments-simultaneously. You can mix pump module types to build the perfect system for your application.
Expandable modular system
Add additional channels when you’re ready. The HAPC is an expandable system. Easy access to add or remove channels.
Intuitive User Interface
The intuitive Harvard Apparatus Pump Controller graphical user interface controlled with a large 7” LCD color touch screen display allows quick and easy setup for each channel. The display run screen presents the user with all key dispensing parameters for up to four syringe pumps in real time.
Full Method Programmability
The HAPC offers preprogrammed flow methods for simple to complex operations that allow you to be up and running with the push of a button. You can even save your flow profiles on the HAPC and use them when needed. Create constant rates, flow ramps, bolus, concentration and more!
Syringe Pump Modules
Nanomite Stereotaxic Injector |
Nanomite Stereotaxic Injector syringe pump module provides precise, acute stereotaxic infusion. Compatible with all stereotaxic frames, the Nanomite can provide pinpoint accuracy for preclinical neuroscience injections. Please follow this link to see Harvard Apparatus stereotaxic frame options.
|
Pump 11 Elite |
Pump 11 Elite series provides small to medium volume infusion in a compact size and high accuracy. The Pico Plus option provides smooth flow down to the pl/min. Both platforms are available in single and dual syringe configurations.
|
PHD ULTRA™ |
PHD ULTRA™ high precision mechanism in a sturdy enclosure. Our smoothest flow with two simultaneous channels. Using four of the PHD ULTRA™ modules will provide eight flow streams. Each PHD ULTRA™ module can run independently of the others for true fluidic flexibility.
|
PHD ULTRA™ Push/Pull |
PHD ULTRA™ Push/Pull high precision continuous flow mechanism. When you need smooth and precise continuous syringe pump flow at peristaltic pump volumes, using four of the PHD ULTRA™ Push/Pull modules will provide four precise continuous flow streams, without the flow pulsatility of a peristaltic pump.
|
PHD ULTRA™ 4400 |
The PHD ULTRA™ 4400 high pressure, enclosed syringe pump component with excellent precisions. Ideal for pumping viscous solutions.
|
PHD ULTRA™ XF |
The PHD ULTRA™ XF our highest pressure four channel syringe pump module. Controlling up to four of these mechanisms can provide sixteen high pressure flow streams.
|
Harvard Apparatus Syringe Pump Accuracy and Precision
All syringe pumps are not created equal. The graphs above show the flow performance of the Pump 11 Elite and PHD ULTRA™ versus competitive pumps run under the same conditions. The PURPLE and BLUE graphs show the smoothness of our syringe pumps when compared to our competitors (RED, OLIVE, GREEN & ORANGE). When volume accuracy and flow stability are important to your experiments only Harvard Apparatus delivers
Harvard Apparatus offers syringes, tubing, connectors and stereotaxic frames as accessories to our world class syringe pumps.
Please follow this link for syringe options.
Please follow this link for tubing and connector options.
Please follow this link to see Harvard Apparatus stereotaxic frame options.
CONTROLLER SPECIFICATIONS | |||||
Catalog Number | 70-4401 | 70-4402 | 70-4403 | 70-4404 | |
Channels | 1 | 2 | 3 | 4 | |
Display | 7" WQVGA TFT Color Display with Touch Screen | ||||
Mode of Operation | Continuous with Method and conditional syringe pump control features | ||||
Non-Volatile Memory | Stores all settings | ||||
Connectors: | |||||
RS-485 | IEEE-1394, 6 pos | ||||
USB | Type B | ||||
I/O & TTL | 15 pin D-Sub connector, per channel | ||||
Footswitch | Mini phono jack (one per channel) | ||||
8-Pin Phoenix | For channel connection to Nanomite Module | ||||
Voltage Range | 100-240 VAC, 50/60 Hz | ||||
Dimensions (L X W X H) | 8.75 x 10 x 6.25 in (22 x 25.4 x 15.87 cm) | ||||
Weight (populated with four channels) | 2.3 kg (5 lbs) | ||||
Atmospheric Conditions: | |||||
Operating Temperature | 4°C to 40°C (40°F to 104°F) | ||||
Storage Temperature | -10°C to 70°C (14°F to 158°F) | ||||
Storage Humidity | 20% to 80% RH, non condensing | ||||
Power | 100 to 240 VAC, 50/60 Hz 50 W, 0.5 A fuse | ||||
Classification | Class 1 | ||||
Pollution Degree | 1 | ||||
Installation Category | II | ||||
Regulatory Certifications | CE, ETL (UL, CSA), WEEE, EU RoHS & CB Scheme | ||||
Safety Declarations | ANSI/UL 61010-1; CAN/CSA C22.2 No. 61010-1; IEC 61010-1; CB Scheme | ||||
EMC Declaration | FCC 47CFR 15B; EN61326-1 |
MODULE SPECIFICATIONS | ||||||
Specifications | Nanomite Injector |
Pump 11 Elite Syringe Pump Module |
Pump 11 Pico Plus Elite Syringe Pump Module |
PHD ULTRA™ Syringe Pump Module |
PHD ULTRA™ 4400 Syringe Pump Module |
PHD ULTRA™ XF Syringe Pump Module |
Item # | 70-3601 (Single) | 70-4804 (Single) 70-4805 (Dual) |
70-4806 (Dual) 70-4807 (Single) |
70-3406 (Dual) 70-3408 (Push/Pull) |
70-3410 (Single) | 70-3514 (Four) |
Channels | 1 | 1 or 2 | 1 or 2 | 2 | 1 | 4 |
Accuracy | ±0.5% | ±0.5% | ± 0.35% | ± 0.25% | ± 0.35% | ± 0.5% |
Syringe (Min./Max.) | 0.5 µl / 1 ml | 0.5 μl / 60 ml (10 ml dual) | 0.5 μl / 60 ml (10 ml dual) | 0.5 µl / 140 ml | 0.5 µl / 140 ml | 20 ml / 200 ml |
Flow Rate: | ||||||
Minimum | 3.66 pl/min (0.5 µl syringe) |
1.26 pl/min | 0.54 pl/min | 3.16 pl/min (0.5 µl syringe) |
3.16 pl/min (0.5 µl syringe) |
50.7 nl/min (20 ml syringe) |
Maximum | 3.82 ml/min (1 ml syringe) | 88.40 ml/min (26.02 ml/min dual) |
39.77 ml/min (11.70 ml/min dual) |
215.8 ml/min (140 ml syringe) |
215.8 ml/min (140 ml syringe) |
144.08 ml/min (200 ml syringe) |
Display | None | None | None | None | None | None |
Non-Volatile Memory | None (on HAPC) | Stores all settings | Stores all settings | Stores all settings | Stores all settings | Stores all settings |
Connectors: | ||||||
RS-485 | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications |
USB | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications |
I/O & TTL | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications |
Footswitch | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications |
RS-232 | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications |
8-Pin Phoenix | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications |
Linear Force (Max) @ 100% Force selection |
5 kg (11 lbs) | 16 kg (35 lbs) | 16 kg (35 lbs) | 34 kg (75 lb) | 91 kg (200 lb) | 455 kg (1000 lb) |
Drive Motor | 1.8° Stepper Motor | 0.9° Stepper Motor | 0.9° Stepper Motor | 0.9° Stepper Motor | 0.9° Stepper Motor | 0.9° Stepper Motor |
Motor Drive Control | Microprocessor with 1/16 microstepping |
Microprocessor with 1/16 microstepping |
Microprocessor with 1/16 microstepping |
Microprocessor with 1/16 microstepping |
Microprocessor with 1/16 microstepping |
Microprocessor with 1/16 microstepping |
Microsteps/revolution of lead screw |
3,200 | 15,360 | 20,480 | 12,800 | 6,400 | 32,000 |
Step Resolution | 0.198 μm/μstep | 0.069 μm/μstep | 0.031 μm/μstep | 0.082 µm/µstep | 0.082 µm/µstep | 0.082 µm/µstep |
Step Rate: | ||||||
Minimum | 27.5 sec/μstep | 27.5 sec/μstep | 27.5 sec/μstep | 27.5 sec/µstep | 27.5 sec/µstep | 27.5 sec/µstep |
Maximum | 52 μsec/μstep | 52 μsec/μstep | 52 μsec/μstep | 26 µsec/µstep | 52 µsec/µstep | 52 µsec/µstep |
Pusher Travel Rate: | ||||||
Minimum | 0.433 μm/min | 0.15 μm/min | 0.068 μm/min | 0.18 µm/min | 0.36 µm/min | 0.18 µm/min |
Maximum | 228.97 mm/min | 159.00 mm/min | 71.55 mm/min | 190.80 mm/min | 190.80 mm/min | 91.637 mm/min |
Stall Detection | No | Yes | Yes | Yes | Yes | Yes |
Input Power* | Powered by HAPC* | Powered by HAPC* | Powered by HAPC* | Powered by HAPC* | Powered by HAPC* | Powered by HAPC* |
Dimensions (L X W X H) |
2.5 x 2.0 x 7.5 in (6.35 x 5.08 x 19.05 cm) |
24.13 x 17.15 x 10.67 cm (9.5 x 6.75 x 4.2 in) |
24.13 x 17.15 x 10.67 cm (9.5 x 6.75 x 4.2 in) |
11.75 x 5.5 x 6.5 in (29.8 x 14.0 x 16.5 cm) |
11.75 x 5.5 x 6.5 in (29.8 x 14.0 x 16.5 cm) |
16 x 12 x 8.5 in (40.64 x 30.48 x 21.6 cm) |
Dimensions: Nanomite Mounting post |
Length 3.25 in (8.25 cm) OD: 0.312 in (0.793 cm) |
Nanomite Only | Nanomite Only | Nanomite Only | Nanomite Only | Nanomite Only |
Weight (injector/module only) | 0.54kg (1.2 lb) | 2.3 kg (5.08 lbs) | 2.3 kg (5.08 lbs) | 5.1 kg (11.2 lb) | 5.3 kg (11.7 lb) | 20 kg (44 lb) |
Atmospheric Conditions | ||||||
Operating Temperature | 4°C to 40°C (40°F to 104°deg;F) |
4°C to 40°C (40°F to 104°F) |
4°C to 40°C (40°F to 104°F) |
4°C to 40°C (40°F to 104°F) |
4°C to 40°C (40°F to 104°F) |
4°C to 40°C (40°F to 104°F) |
Storage Temperature | -10°C to 70°C (14°F to 158°F) |
-10°C to 70°C (14°F to 158°F) |
-10°C to 70°C (14°F to 158°F) |
-10°C to 70°C (14°F to 158°F) |
-10°C to 70°C (14°F to 158°F) |
-10°C to 70°C (14°F to 158°F) |
Operating Humidity | See Chart Below | See Chart Below | See Chart Below | See Chart Below | See Chart Below | See Chart Below |
Storage Humidity | 20% to 80% RH, non condensing |
20% to 80% RH, non condensing |
20% to 80% RH, non condensing |
20% to 80% RH, non condensing |
20% to 80% RH, non condensing |
20% to 80% RH, non condensing |
Method of Operation | Continuous | Continuous | Continuous | Continuous | Continuous | Continuous |
Classification | Class I | Class I | Class I | Class I | Class I | Class I |
Pollution Degree | 1 | 1 | 1 | 1 | 1 | 1 |
Installation Category | II | II | II | II | II | II |
Regulatory Certifications | CE, ETL (UL, CSA), WEEE, EU RoHS & CB Scheme |
CE, ETL (UL, CSA), WEEE, EU RoHS & CB Scheme |
CE, ETL (UL, CSA), WEEE, EU RoHS & CB Scheme |
CE, ETL (UL, CSA), WEEE, EU RoHS & CB Scheme |
CE, ETL (UL, CSA), WEEE, EU RoHS & CB Scheme | CE, ETL (UL, CSA), WEEE, EU RoHS & CB Scheme |
Safety Declarations | ANSI/UL 61010-1; CAN/CSA C22.2 No. 61010-1; IEC 61010-1; CB Scheme |
ANSI/UL 61010-1; CAN/CSA C22.2 No. 61010-1; IEC 61010-1; CB Scheme |
ANSI/UL 61010-1; CAN/CSA C22.2 No. 61010-1; IEC 61010-1; CB Scheme |
ANSI/UL 61010-1; CAN/CSA C22.2 No. 61010-1; IEC 61010-1; CB Scheme |
ANSI/UL 61010-1; CAN/CSA C22.2 No. 61010-1; IEC 61010-1; CB Scheme |
ANSI/UL 61010-1; CAN/CSA C22.2 No. 61010-1; IEC 61010-1; CB Scheme |
EMC Declaration | FCC 47CFR 15B; EN61326-1 |
FCC 47CFR 15B; EN61326-1 |
FCC 47CFR 15B; EN61326-1 |
FCC 47CFR 15B; EN61326-1 |
FCC 47CFR 15B; EN61326-1 |
FCC 47CFR 15B; EN61326-1 |
Note* The Pump 11 Elite, Pico Plus Elite and PHD ULTRA™ XF are fully PC controllable and come with external power supplies. When used with the HAPC, the power supplies are not required. In cases of extremely high pressure applications using the PHD ULTRA XF, the external power supplier may be required. Please contact Technical Support for additional application questions. |
CONTROLLER SPECIFICATIONS | |||||
Catalog Number | 70-4401 | 70-4402 | 70-4403 | 70-4404 | |
Channels | 1 | 2 | 3 | 4 | |
Display | 7" WQVGA TFT Color Display with Touch Screen | ||||
Mode of Operation | Continuous with Method and conditional syringe pump control features | ||||
Non-Volatile Memory | Stores all settings | ||||
Connectors: | |||||
RS-485 | IEEE-1394, 6 pos | ||||
USB | Type B | ||||
I/O & TTL | 15 pin D-Sub connector, per channel | ||||
Footswitch | Mini phono jack (one per channel) | ||||
8-Pin Phoenix | For channel connection to Nanomite Module | ||||
Voltage Range | 100-240 VAC, 50/60 Hz | ||||
Dimensions (L X W X H) | 8.75 x 10 x 6.25 in (22 x 25.4 x 15.87 cm) | ||||
Weight (populated with four channels) | 2.3 kg (5 lbs) | ||||
Atmospheric Conditions: | |||||
Operating Temperature | 4°C to 40°C (40°F to 104°F) | ||||
Storage Temperature | -10°C to 70°C (14°F to 158°F) | ||||
Storage Humidity | 20% to 80% RH, non condensing | ||||
Power | 100 to 240 VAC, 50/60 Hz 50 W, 0.5 A fuse | ||||
Classification | Class 1 | ||||
Pollution Degree | 1 | ||||
Installation Category | II | ||||
Regulatory Certifications | CE, ETL (UL, CSA), WEEE, EU RoHS & CB Scheme | ||||
Safety Declarations | ANSI/UL 61010-1; CAN/CSA C22.2 No. 61010-1; IEC 61010-1; CB Scheme | ||||
EMC Declaration | FCC 47CFR 15B; EN61326-1 |
MODULE SPECIFICATIONS | ||||||
Specifications | Nanomite Injector |
Pump 11 Elite Syringe Pump Module |
Pump 11 Pico Plus Elite Syringe Pump Module |
PHD ULTRA™ Syringe Pump Module |
PHD ULTRA™ 4400 Syringe Pump Module |
PHD ULTRA™ XF Syringe Pump Module |
Item # | 70-3601 (Single) | 70-4804 (Single) 70-4805 (Dual) |
70-4806 (Dual) 70-4807 (Single) |
70-3406 (Dual) 70-3408 (Push/Pull) |
70-3410 (Single) | 70-3514 (Four) |
Channels | 1 | 1 or 2 | 1 or 2 | 2 | 1 | 4 |
Accuracy | ±0.5% | ±0.5% | ± 0.35% | ± 0.25% | ± 0.35% | ± 0.5% |
Syringe (Min./Max.) | 0.5 µl / 1 ml | 0.5 μl / 60 ml (10 ml dual) | 0.5 μl / 60 ml (10 ml dual) | 0.5 µl / 140 ml | 0.5 µl / 140 ml | 20 ml / 200 ml |
Flow Rate: | ||||||
Minimum | 3.66 pl/min (0.5 µl syringe) |
1.26 pl/min | 0.54 pl/min | 3.16 pl/min (0.5 µl syringe) |
3.16 pl/min (0.5 µl syringe) |
50.7 nl/min (20 ml syringe) |
Maximum | 3.82 ml/min (1 ml syringe) | 88.40 ml/min (26.02 ml/min dual) |
39.77 ml/min (11.70 ml/min dual) |
215.8 ml/min (140 ml syringe) |
215.8 ml/min (140 ml syringe) |
144.08 ml/min (200 ml syringe) |
Display | None | None | None | None | None | None |
Non-Volatile Memory | None (on HAPC) | Stores all settings | Stores all settings | Stores all settings | Stores all settings | Stores all settings |
Connectors: | ||||||
RS-485 | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications |
USB | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications |
I/O & TTL | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications |
Footswitch | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications |
RS-232 | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications |
8-Pin Phoenix | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications | See HAPC specifications |
Linear Force (Max) @ 100% Force selection |
5 kg (11 lbs) | 16 kg (35 lbs) | 16 kg (35 lbs) | 34 kg (75 lb) | 91 kg (200 lb) | 455 kg (1000 lb) |
Drive Motor | 1.8° Stepper Motor | 0.9° Stepper Motor | 0.9° Stepper Motor | 0.9° Stepper Motor | 0.9° Stepper Motor | 0.9° Stepper Motor |
Motor Drive Control | Microprocessor with 1/16 microstepping |
Microprocessor with 1/16 microstepping |
Microprocessor with 1/16 microstepping |
Microprocessor with 1/16 microstepping |
Microprocessor with 1/16 microstepping |
Microprocessor with 1/16 microstepping |
Microsteps/revolution of lead screw |
3,200 | 15,360 | 20,480 | 12,800 | 6,400 | 32,000 |
Step Resolution | 0.198 μm/μstep | 0.069 μm/μstep | 0.031 μm/μstep | 0.082 µm/µstep | 0.082 µm/µstep | 0.082 µm/µstep |
Step Rate: | ||||||
Minimum | 27.5 sec/μstep | 27.5 sec/μstep | 27.5 sec/μstep | 27.5 sec/µstep | 27.5 sec/µstep | 27.5 sec/µstep |
Maximum | 52 μsec/μstep | 52 μsec/μstep | 52 μsec/μstep | 26 µsec/µstep | 52 µsec/µstep | 52 µsec/µstep |
Pusher Travel Rate: | ||||||
Minimum | 0.433 μm/min | 0.15 μm/min | 0.068 μm/min | 0.18 µm/min | 0.36 µm/min | 0.18 µm/min |
Maximum | 228.97 mm/min | 159.00 mm/min | 71.55 mm/min | 190.80 mm/min | 190.80 mm/min | 91.637 mm/min |
Stall Detection | No | Yes | Yes | Yes | Yes | Yes |
Input Power* | Powered by HAPC* | Powered by HAPC* | Powered by HAPC* | Powered by HAPC* | Powered by HAPC* | Powered by HAPC* |
Dimensions (L X W X H) |
2.5 x 2.0 x 7.5 in (6.35 x 5.08 x 19.05 cm) |
24.13 x 17.15 x 10.67 cm (9.5 x 6.75 x 4.2 in) |
24.13 x 17.15 x 10.67 cm (9.5 x 6.75 x 4.2 in) |
11.75 x 5.5 x 6.5 in (29.8 x 14.0 x 16.5 cm) |
11.75 x 5.5 x 6.5 in (29.8 x 14.0 x 16.5 cm) |
16 x 12 x 8.5 in (40.64 x 30.48 x 21.6 cm) |
Dimensions: Nanomite Mounting post |
Length 3.25 in (8.25 cm) OD: 0.312 in (0.793 cm) |
Nanomite Only | Nanomite Only | Nanomite Only | Nanomite Only | Nanomite Only |
Weight (injector/module only) | 0.54kg (1.2 lb) | 2.3 kg (5.08 lbs) | 2.3 kg (5.08 lbs) | 5.1 kg (11.2 lb) | 5.3 kg (11.7 lb) | 20 kg (44 lb) |
Atmospheric Conditions | ||||||
Operating Temperature | 4°C to 40°C (40°F to 104°deg;F) |
4°C to 40°C (40°F to 104°F) |
4°C to 40°C (40°F to 104°F) |
4°C to 40°C (40°F to 104°F) |
4°C to 40°C (40°F to 104°F) |
4°C to 40°C (40°F to 104°F) |
Storage Temperature | -10°C to 70°C (14°F to 158°F) |
-10°C to 70°C (14°F to 158°F) |
-10°C to 70°C (14°F to 158°F) |
-10°C to 70°C (14°F to 158°F) |
-10°C to 70°C (14°F to 158°F) |
-10°C to 70°C (14°F to 158°F) |
Operating Humidity | See Chart Below | See Chart Below | See Chart Below | See Chart Below | See Chart Below | See Chart Below |
Storage Humidity | 20% to 80% RH, non condensing |
20% to 80% RH, non condensing |
20% to 80% RH, non condensing |
20% to 80% RH, non condensing |
20% to 80% RH, non condensing |
20% to 80% RH, non condensing |
Method of Operation | Continuous | Continuous | Continuous | Continuous | Continuous | Continuous |
Classification | Class I | Class I | Class I | Class I | Class I | Class I |
Pollution Degree | 1 | 1 | 1 | 1 | 1 | 1 |
Installation Category | II | II | II | II | II | II |
Regulatory Certifications | CE, ETL (UL, CSA), WEEE, EU RoHS & CB Scheme |
CE, ETL (UL, CSA), WEEE, EU RoHS & CB Scheme |
CE, ETL (UL, CSA), WEEE, EU RoHS & CB Scheme |
CE, ETL (UL, CSA), WEEE, EU RoHS & CB Scheme |
CE, ETL (UL, CSA), WEEE, EU RoHS & CB Scheme | CE, ETL (UL, CSA), WEEE, EU RoHS & CB Scheme |
Safety Declarations | ANSI/UL 61010-1; CAN/CSA C22.2 No. 61010-1; IEC 61010-1; CB Scheme |
ANSI/UL 61010-1; CAN/CSA C22.2 No. 61010-1; IEC 61010-1; CB Scheme |
ANSI/UL 61010-1; CAN/CSA C22.2 No. 61010-1; IEC 61010-1; CB Scheme |
ANSI/UL 61010-1; CAN/CSA C22.2 No. 61010-1; IEC 61010-1; CB Scheme |
ANSI/UL 61010-1; CAN/CSA C22.2 No. 61010-1; IEC 61010-1; CB Scheme |
ANSI/UL 61010-1; CAN/CSA C22.2 No. 61010-1; IEC 61010-1; CB Scheme |
EMC Declaration | FCC 47CFR 15B; EN61326-1 |
FCC 47CFR 15B; EN61326-1 |
FCC 47CFR 15B; EN61326-1 |
FCC 47CFR 15B; EN61326-1 |
FCC 47CFR 15B; EN61326-1 |
FCC 47CFR 15B; EN61326-1 |
Note* The Pump 11 Elite, Pico Plus Elite and PHD ULTRA™ XF are fully PC controllable and come with external power supplies. When used with the HAPC, the power supplies are not required. In cases of extremely high pressure applications using the PHD ULTRA XF, the external power supplier may be required. Please contact Technical Support for additional application questions. |