harvardapparatus.com is a data controller for the purposes of the General Data Protection Regulation ("GDPR"). By proceeding to tick the consent box at right, you consent to harvardbioscience.com processing your personal data, under the GDPR and any other applicable legislation, that we collect from you in accordance with our Privacy Policy. If you wish to withdraw your consent for us to process your personal data please contact our Compliance Team. Please address any questions, comments and requests (including your right to withdraw your consent to process your personal data) regarding our data processing practices to our Compliance Team.
Allow

Ventilation Options for IPL-1

Price on Request
SKU
GRP-VENT-734279

For a functional unit the core system requires a suitable ventilation system. For only positive ventilation a mouse ventilator can be used. If positive and sub-atmospheric pressure ventilation are required, the Ventilation Control Module must be purchased.

Grouped product items
Item No. Description Qty
73-4279 Negative Pressure Ventilation Control Option with Pump for IPL-1 and IPL-2 Please login to add to Quote
73-4293 Negative Pressure Ventilation Control Option with Pressure Regulator for IPL-1 and IPL-2 Please login to add to Quote
73-2789 IPL-1 Gas Inlet Adapter, including needle valve Please login to add to Quote
73-2919 Multi-Gas Inlet Adapter and stand to connect Aerosol Nebulizer and MicroVent, MiniVent or MidiVent Please login to add to Quote

For a functional unit the core system requires a suitable ventilation system. For only positive ventilation a mouse ventilator can be used. If positive and sub-atmospheric pressure ventilation are required, the Ventilation Control Module must be purchased.

Positive and Sub-Atmospheric (Negative) Pressure Ventilation with Ventilation Control Module (VCM)

  • Used to control the ventilation of the isolated lung preparation. Allows for the physiological negative pressure ventilation of the lung and positive ventilation during preparation.
  • 30 to 100 breaths per minute.
  • I:E ratio can be set between 10 and 90% in 10% steps.
  • End-inspiratory, end-expiratory, sigh, positive and negative pressures can be individually set.
  • The TCM Timer Counter Module allows periodic sigh (hyperinflation) breaths to minimize edema formation.
  • An adapter to supply the trachea with a gas mixture different than room air during negative ventilation can be added.

Negative Pressure Ventilation Control Option with Pump for IPL-1 (73-4279) includes:
Utilizes 6 slot units

Negative PressureVentilation Control Option with Pressure Regulator for IPL-1 (73-4293) includes:
Utilizes 6 slot units
Item # Product Name Item # Product Name
73-1741  PLUGSYS Ventilation Control Module with Integral Pump(VCM-P) 73-2795  PLUGSYS Ventilation Control Module with Regulator(VCM-R)*
73-1750  PLUGSYS Time Counter Module (TCM) 73-1750  PLUGSYS Time Counter Module (TCM)
N/A  See above 73-2789  Pressure-Free Gas SupplyAdapter for Alternative GasSupply**

* Negative pressure ventilation with a pressure regulator (73-4293) built into the VCM-R requires a pressurized gas supply from a tank or house air in the range of 2 to 8 bar (29 to 116 PSI).

** The Pressure-Free Gas Supply Adapter (73-2789) is only for use during sub-atmospheric pressure ventilation with either the VCM-P or VCM-Rand is used to supply alternative gas mixtures to the lungs.

Positive Pressure Ventilation Only

If only positive pressure ventilation will be used, choose an option below.

  • Ventilation rate from 60 to 400 breaths per minute.
  • Stroke volume 30 to 350 µl, simple adjustment while running.
  • Compact size allows positioning close to system for minimal system volume.
 Positive PressureVentilation Option, 230 V (73-4305) includes:   Positive PressureVentilation Option, 115 V (73-4306) includes
Item # Product Name Item # Product Name
73-0044  Mouse Ventilator MiniVent Type 845, 230 V 73-0043  Mouse Ventilator MinVent Type 845, 115 V
73-2792  Y-Adapter to Connect External Respirator to IPL-1 73-2792  Y-Adapter to Connect External Respirator to IPL-1