Pulmonary Artery Cannulating Options for IH-SR and IH-5 (for Effluent Collection)

73-4395 Cannulating system for Rat or Guinea Pig Pulmonary Artery on IH-SR or IH5 systems

Cannulating options for effluate collection from an IH-SR or IH-5 functional system for metabolic studies, sampling the effluate for analysis, or for continuous pO2, pH, pCO2 measurements. Preparation dish and collection funnel available for mouse heart.

To ensure that your system is properly configured as a functional unit that meets your application needs, please contact Technical Services at 800-547-6766 or via email at support@hbiosci.com before placing an order. In Europe, please call +49 7665 92000 or via email at sales@hugo-sachs.de. Upgrades can also be modified to meet your specific needs.

Item# Description U.S. List Price Quantity
73-4395 Cannulating Option for Rat or Guinea Pig Pulmonary Artery for IH-SR
73-4396 Cannulating Option for Mouse Right Ventricle for IH-SR
73-0206 Cannulating Option for Rat or Guinea Pig Pulmonary Artery for IH-5
73-0517 Cannulating Option for Rabbit Pulmonary Artery for IH-5
73-3329 Effluate Funnel for Isolated Heart System IH-SR
Login for U.S. Pricing


These cannulating systems are used to sample coronary effluent for further analysis on your own equipment, for metabolic studies, or for pO2, pH, and pCO2 measurements.

On rat, guinea pig and rabbit hearts the coronary effluate is sampled via cannulation through the pulmonary artery. On mouse hearts the pulmonary artery cannot be cannulated, therefore a small polyethylene catheter is placed directly into the right ventricle.

Item # Description
73-4395 Cannulating Option for Rat or Guinea Pig Pulmonary Artery for IH-SR or IH-5 Systems includes bent cannula for pulmonary artery, mini ball joint holder, link for higher loading capacity, mini ball and Tygon® tubing. For rat and guinea pig heat only. Cannot be used with mouse heart due to the small size of the pulmonary artery.
73-4396 Cannulating Option for Mouse Right Ventricle for IH-SR includes two mini holders, mini ball with thread, ball to hold PE catheterand PE tubing.
On mice hearts the pulmonary artery cannot be cannulated; therefore a small PE catheter is placed into the right ventricle.
73-0206 Cannulating Option for Rat or Guinea Pig Pulmonary Artery for IH-5, OD = 2.5 mm
73-0517 Cannulating System for Rabbit Pulmonary Artery on IH-5  includes 4.0 mm OD bent cannula with holder and perspexblock clamp.
73-0129 Small Preparation Dish for Mouse Hearts on IH-SR  wiht link for IH-SR cannula
Used for mouse heart preparation where the isolated mouse heart must be fixed on the aortic cannula under a microscope. Prep dish is placed on ice and filled with 4°C cold solution in order to keep metabolic function and ischemia low.   
73-3329 Effluate Funnel for Isolated Heart System IH-SR 
Fits into lower lid of the IH-SR system. Used to collect hearts effluate which drops down from the isolated heart into this funnel. Must also be used for recirculating experiments on IH-SR systems.

Specifications