array(3) { ["show"]=> bool(true) ["ip"]=> string(13) "74.80.208.120" ["country"]=> string(2) "US" } desde la funcion de ip obtenemos IP invalida
harvardapparatus.com is a data controller for the purposes of the General Data Protection Regulation ("GDPR"). By proceeding to tick the consent box at right, you consent to harvardbioscience.com processing your personal data, under the GDPR and any other applicable legislation, that we collect from you in accordance with our Privacy Policy. If you wish to withdraw your consent for us to process your personal data please contact our Compliance Team. Please address any questions, comments and requests (including your right to withdraw your consent to process your personal data) regarding our data processing practices to our Compliance Team.
Allow

Standard Flow Probes (S-Series - L Reflector)

Price on Request
SKU
GRP-SPROBESL

Limited available quantities.  Please contact us for further information.

For direct measurement of volume flow for vessels from 2 to 20 mm diameter using the PLUGSYS transit time flow meter module (TTFM-2).

These probes have the transducers positioned at an 60° angle to the vessel. This reduces the flow probe body size and reflector width for placement of the probe in applications where space is limited. These probes are available with the cable exit in the back or on the side.

For information on flow probes to interface with the earlier versions of the TTFM (73-0146) please contact Technical Services.

Grouped product items
Item No. Description Qty
73-4643 MA1.5 PSL Flow probe for HSE TTFM-2 or TS420 module Please login to add to Quote
73-4646 MA2PSS Flow probe for HSE TTFM-2 or TS420 module Please login to add to Quote
73-4648 MA2.5PSS Flow probe for HSE TTFM-2 or TS420 module Please login to add to Quote
73-4649 MA2.5PSL Flow probe for HSE TTFM-2 or TS420 module Please login to add to Quote
73-4651 MA3PSS Flow probe for HSE TTFM-2 or TS420 module Please login to add to Quote
73-4653 MA4 PSS Flow probe for HSE TTFM-2 or TS420 module Please login to add to Quote
73-4655 MA6 PSS Flow probe for HSE TTFM-2 or TS420 module Please login to add to Quote
73-4657 MA8PSS Flow probe for HSE TTFM-2 or TS420 module Please login to add to Quote
73-4658 MA10PSB Flow probe for HSE TTFM-2 or TS420 module Please login to add to Quote
73-4659 MA10PSS Flow probe for HSE TTFM-2 or TS420 module Please login to add to Quote
73-4661 MA12PSS Flow probe for HSE TTFM-2 or TS420 module Please login to add to Quote
73-4662 MA14PSB Flow probe for HSE TTFM-2 or TS420 module Please login to add to Quote
73-4663 MA14PSS Flow probe for HSE TTFM-2 or TS420 module Please login to add to Quote
73-4664 MA16PSB Flow probe for HSE TTFM-2 or TS420 module Please login to add to Quote
73-4665 MA16PSS Flow probe for HSE TTFM-2 or TS420 module Please login to add to Quote
73-4666 MA20PSB Flow probe for HSE TTFM-2 or TS420 module Please login to add to Quote
73-4667 MA20PSS Flow probe for HSE TTFM-2 or TS420 module Please login to add to Quote

For direct measurement of volume flow for vessels from 2 to 20 mm diameter using the PLUGSYS transit time flow meter module (TTFM-2).

These probes have the transducers positioned at an 60° angle to the vessel. This reduces the flow probe body size and reflector width for placement of the probe in applications where space is limited. These probes are available with the cable exit in the back or on the side. (Photo shows side exit.)

Coding:

  • SB:  S-probe with cable exit in the Back
  • SS:  S-probe with cable exit on the Side 

Probe diameters between 2 and 2.5 mm do have a J reflector with slide cover
Probe diameters between 3 and 20 mm do have a L reflector with slide cover

For information on flow probes to interface with the earlier versions of the TTFM (73-0146) please contact Technical Services.

Diameters 3 mm - 6 mm

Item Number 73-4650

73-4651

73-4652 73-4653 73-4654 73-4655
Diameter  3 mm 3 mm  4 mm 4 mm 6 mm  6 mm
OD Vessel Acute 2.5 - 3.7 2.5 - 3.7 3.3 - 4.4 3.3 - 4.4 4.4 - 6.6 .4.4 - 6.6
Resolution ml/min 0.4 0.4 0.8 0.8 2.2 2.2

Range ml/min

Sc. Low

 

50

 

50

 

100

 

100

 

50

 

50

Sc. Norm 200 200 400 400 1 L 1 L
Max  1 L 1 L 2 L 2 L 5 L 5 L
Probe Length 9 mm  9 mm 13.3 mm 13.3 mm 13.5 mm 13.5 mm
Probe Width  5 mm 5 mm 6 mm 6 mm 6.7 mm 6.7 mm
Cable Length  100 cm  100 cm  100 cm  100 cm  100 cm  100 cm 
Cable Exit Back  Side  Back  Side  Back  Side 

 

Diameters 8 mm - 12 mm 

Item Number  73-4656 73-4657 73-4658 73-4659 73-4660 73-4661
Diameter 8 mm 8 mm 10 mm  10 mm 12 mm 12 mm
OD Vessel Acute 6.6 - 8.8 6.6 - 8.8 8.3 - 11.0 8.3 - 11.0 9.8 - 13 9.8 - 13
Resolution ml/min 4 4 8 8 8 8

Range ml/min

Sc. Low 

 

500

 

500

 

500

 

500

 

1L

 

1L

Sc. Norm  2 L 2 L  2 L 2 L  4 L 4 L
Max  10 L  10 L 10 L  10 L 20 L 20 L
Probe Length  18.8 mm 18.8 mm 18.7 mm 18.7 mm 22.5 mm 22.5 mm
Probe Width  7.5 mm 7.5 mm 8.5 mm 8.5 mm 8.5 mm 8.5 mm
Cable Length  100 cm  100 cm  100 cm 100 cm 100 cm 100 cm 
Cable Exit  Back  Side  Back  Side  Back  Side 

 

Diameter 14 mm - 20 mm 

Item Number 73-4662 73-4663 73-4664 73-4665 734666 73-4667
Diameter 14 mm 14 mm 16 mm 16 mm 20 mm 20 mm
OD Vessel Acute  11.3 - 15.0 11.3 - 15.0 13.3 - 17.7 13.3 - 17.7 16.0 - 21.0 16.0 - 21.0
Resolution ml/min 16 16 20 20 40 40

Range ml/min

Sc. Low

 

1 L

 

1 L

 

2.5 L

 

2.5 L

 

2.5 L

 

2.5 L

Sc. Norm  4 L 4 L 10 L  10 L  10 L  10 L 
Max 20 L 20 L  50 L  50 L  50 L  50 L 
Probe Length 26.2 mm 26.2 mm 36 mm 36 mm 31 mm 31 mm
Probe Width  8.5 mm 8.5 mm 10 mm 10 mm 9 mm 9 mm
Cable Length  100 cm 100 cm 100 cm 100 cm   100 cm 100 cm
Cable Exit  Back Side  Back  Side  Back  Side