array(3) { ["show"]=> bool(true) ["ip"]=> string(12) "83.99.151.67" ["country"]=> string(2) "LV" } desde la funcion de ip obtenemos IP invalida
harvardapparatus.com is a data controller for the purposes of the General Data Protection Regulation ("GDPR"). By proceeding to tick the consent box at right, you consent to harvardbioscience.com processing your personal data, under the GDPR and any other applicable legislation, that we collect from you in accordance with our Privacy Policy. If you wish to withdraw your consent for us to process your personal data please contact our Compliance Team. Please address any questions, comments and requests (including your right to withdraw your consent to process your personal data) regarding our data processing practices to our Compliance Team.
Allow

PHD ULTRA™ 4400 Gradient System

Price on Request
SKU
24c7ccbe

The PHD ULTRA™ 4400 Gradient System allows you to quickly and easily run binary or ternary mixtures automatically without a PC. The Method is totally programmed from a master controller pump, so it is easy to program. The intuitive program interface makes simple to complex mixing easy. The Gradient Profile is used to combine multiple flow streams from different pumps into a common output stream. The flow can be smooth and continuous or stepped. No stopping the experiment, mixing different percent volume mixtures and placing new syringes into the pumps. Push one button and it all happens automatically.

This capability of Harvard Apparatus syringe pumps to completely deliver percent composition changes automatically with high accuracy and precision flow provides an economical tool to advance experiments and eliminate manual input for complex solution changes.

Binary and ternary gradient systems are available with or without a stand. Individual Satellite units are also available for purchase separately.

Please follow this link for more information on the PHD ULTRA™ 4400 Infuse/Withdraw Programmable Syrigne Pump.

Please follow this link for information about individual PHD ULTRA™ satellite units.

Grouped product items
Item No. Description Qty
No options of this product are available.

The PHD ULTRA™ 4400 Gradient System allows you to quickly and easily run binary or ternary mixtures automatically without a PC. The Method is totally programmed from a master controller pump, so it is easy to program. The intuitive program interface makes simple to complex mixing easy. The Gradient Profile is used to combine multiple flow streams from different pumps into a common output stream. The flow can be smooth and continuous or stepped. No stopping the experiment, mixing different percent volume mixtures and placing new syringes into the pumps. Push one button and it all happens automatically. This capability of Harvard Apparatus syringe pumps to completely deliver percent composition changes automatically with high accuracy and precision flow provides an economical tool to advance experiments and eliminate manual input for complex solution changes. 


Features

  • Easily run binary or ternary gradients without a PC
  • Combine multiple flow streams into one common output
  • No Stopping experiment to fill syringes with different mixtures


Applications

  • Serial dilutions of reaction dosing solutions
  • Serial dilution for drug infusion experiments
  • Serial dilutions for nutritional infusion experiments
  • Serial dilutions for mixing polymers in electrospinning
  • Chromatography
  • FIA systems


Binary and ternary gradient systems are available with or without a stand. Individual Satellite units are also available for purchase separately.

Please follow this link for more information on the PHD ULTRA™ 4400 Infuse/Withdraw Programmable Syrigne Pump.

Please follow this link for information about individual PHD ULTRA™ satellite units.

Specifications70-410370-410470-410870-4109
Accuracy±0.35%±0.35%±0.35%±0.35%
ClassificationClass IClass IClass IClass I
Dimensions
L x D x H
4 x 12 x 8.5 in (10.16 x 30.48 x 21.59 cm)4 x 12 x 8.5 in (10.16 x 30.48 x 21.59 cm)4 x 12 x 8.5 in (10.16 x 30.48 x 21.59 cm)
Display4.3" WQVGA TFT Color Display with Touch Screen4.3" WQVGA TFT Color Display with Touch Screen4.3" WQVGA TFT Color Display with Touch Screen4.3" WQVGA TFT Color Display with Touch Screen
Drive Motor0.9° Stepper Motor0.9° Stepper Motor0.9° Stepper Motor0.9° Stepper Motor
Environmental Humidity20% to 80% RH, non condensing20% to 80% RH, non condensing20% to 80% RH, non condensing20% to 80% RH, non condensing
Environmental Operating Temperature40°F to 104°F (4°C to 40°C)40°F to 104°F (4°C to 40°C)40°F to 104°F (4°C to 40°C)40°F to 104°F (4°C to 40°C)
Environmental Storage Temperature 14°F to 158°F (-10°C to 70°C)14°F to 158°F (-10°C to 70°C)
Flow Rate Maximum215.8 ml/min using a 140 ml syringe215.8 ml/min using a 140 ml syringe215.8 ml/min using a 140 ml syringe215.8 ml/min using a 140 ml syringe
Flow Rate Minimum3.06 pl/min using a 0.5 µl syringe3.06 pl/min using a 0.5 µl syringe3.06 pl/min using a 0.5 µl syringe3.06 pl/min using a 0.5 µl syringe
I O TTL Connectors15 pin D–Sub Connector15 pin D–Sub Connector15 pin D–Sub Connector15 pin D–Sub Connector
Input Power50 W, 0.5 A fuse50 W, 0.5 A fuse50 W, 0.5 A fuse50 W, 0.5 A fuse
Installation CategoryIIIIIIII
Max Linear Force200 lbs @ 100% Force Selection200 lbs @ 100% Force Selection200 lbs @ 100% Force Selection200 lbs @ 100% Force Selection
Mode of OperationContinuousContinuousContinuousContinuous
Motor Drive ControlMicroprocessor with 1/16 microsteppingMicroprocessor with 1/16 microsteppingMicroprocessor with 1/16 microsteppingMicroprocessor with 1/16 microstepping
Net Weight12.1 lb (5.5 kg)12.1 lb (5.5 kg)12.1 lb (5.5 kg)12.1 lb (5.5 kg)
No of Syringes1 per pump1 per pump1 per pump1 per pump
Non Volatile MemoryStorage of all settingsStorage of all settingsStorage of all settingsStorage of all settings
Number of Microsteps per one rev of Lead Screw6,4006,4006,4006,400
Pollution Degree1111
Pump ConfigurationMaster, SatelliteMaster, SatelliteMaster, SatelliteMaster, Satellite
Pump FunctionInfuse/WithdrawInfuse/WithdrawInfuse/WithdrawInfuse/Withdraw
Pusher Travel Rate Maximum190.8 mm/min190.8 mm/min190.8 mm/min190.8 mm/min
Pusher Travel Rate Minimum0.36 µm/min0.36 µm/min0.36 µm/min0.36 µm/min
RS dash 232 Connectors9 pin D–Sub Connector9 pin D–Sub Connector9 pin D–Sub Connector9 pin D–Sub Connector
Rack TypeStandard RackStandard RackStandard RackStandard Rack
Regulatory CertificationsCE, ETL (UL, CSA), WEEE, EU RoHS and CB SchemeCE, ETL (UL, CSA), WEEE, EU RoHS and CB SchemeCE, ETL (UL, CSA), WEEE, EU RoHS and CB SchemeCE, ETL (UL, CSA), WEEE, EU RoHS and CB Scheme
Step Rate Maximum26 µsec/µstep26 µsec/µstep26 µsec/µstep26 µsec/µstep
Step Rate Minimum27.5 sec/µstep27.5 sec/µstep27.5 sec/µstep27.5 sec/µstep
Syringe Size Maximum140 ml140 ml140 ml140 ml
Syringe Size Minimum0.5 µl0.5 µl0.5 µl0.5 µl
USB ConnectorsType BType BType BType B
Voltage Range100–240 VAC, 50/60 Hz100–240 VAC, 50/60 Hz100–240 VAC, 50/60 Hz100–240 VAC, 50/60 Hz

Xizhong Cui, PhD; Yvonne Fitz, BS; Yan Li, MD; Ping Qiu, Ph.D; Steve Solomon, Ph D; Mariam Al-Hamad, BS & Peter Q. Eichacker, MD (2013 ) Pilot Investigation Of A Multi-Channel Automated Drug Delivery System For Blood Pressure Regulated Vasopressor Administration In A Rat Model ATS Journals

Amber L. Alhadeff , Matthew R. Hayes , Harvey J. Grill (2014 ) Leptin receptor signaling in the lateral parabrachial nucleus contributes to the control of food intake American Journal of Physiology

Vivek Sharma, Simon J. Haward, James Serdy, Bavand Keshavarz, Asa Soderlund, Phil Threlfall-Holmes & Gareth H. McKinley (2015 ) The rheology of aqueous solutions of ethyl hydroxy-ethyl cellulose (EHEC) and its hydrophobically modified analogue (hmEHEC): extensional flow response in capillary break-up, jetting (ROJER) and in a cross-slot extensional rheometer Royal Society of Chemistry

Amber L. Alhadeff, Laura E. Rupprecht, and Matthew R. Hayes (2011 ) GLP-1 Neurons in the Nucleus of the Solitary Tract Project Directly to the Ventral Tegmental Area and Nucleus Accumbens to Control for Food Intake Endocrine Society

Ryan W. Mutharda & Scott L. Diamond (2013 ) Side view thrombosis microfluidic device with controllable wall shear rate and transthrombus pressure gradient Lab On A Chip

G. L. Scaglione, S. Lancellotti1, M. Papi1, M. De Spirito, A. Maiorana, L. Baronciani, M. T. Pagliari, A. Arcovito, E. Di Stasio, F. Peyvandi, R. De Cristofaro (2013 ) The type 2B p.R1306W natural mutation of von Willebrand factor dramatically enhances the multimer sensitivity to shear stress The Journal of Thrombosis and Haemostasis

Youri Gendelb, Oana Davidb & Matthias Wesslinga (2013 ) Microtubes made of carbon nanotubes Science Direct

Jidong Wang, Wenwen Chen, Jiashu Sun, Chao Liu, Qifang Yin, Lu Zhang, Yunlei Xianyu, Xinghua Shi, Guoqing Hu & Xingyu Jiang (2014 ) A microfluidic tubing method and its application for controlled synthesis of polymeric nanoparticles Lab On A Chip

J. D. Welsh, T. V. Colace, R. W. Muthard, T. J. Stalker, L. F. Brass & S. L. Diamond (2012 ) Platelet-targeting sensor reveals thrombin gradients within blood clots forming in microfluidic assays and in mouse The Journal of Thrombosis and Haemostasis

Dominika Ogończyk, Mateusz Gocyla, Marcin Opallo (2014 ) Electrochemical response of catalytic nanoparticles in Flow Injection Analysis system Science Direct

James O. Hardin, Thomas J. Ober, Alexander D. Valentine & Jennifer A. Lewis (2015 ) Microfluidic Printheads for Multimaterial 3D Printing of Viscoelastic Inks Advanced Materials

Nan Li, Miguel F. Diaz, Pamela L. Wenzel Ph.D. (2014 ) Application of Fluid Mechanical Force to Embryonic Sources of Hemogenic Endothelium and Hematopoietic Stem Cells Methods in Molecular Biology

Wahyudionoa, Kanako Murakamia, Siti Machmudahb, Mitsuru Sasakia & Motonobu Gotob (2011 ) Production of nanofibers by electrospinning under pressurized CO2 High Pressure Research: An International Journal

Iulia - Rodica Damian, Nicoleta Octavia Tănase, Ștefan - Mugur Simionescu, Mona Mihăilescu (2015 ) Vortex Rings - Experiments and Numerical Simulations Mathematical Modelling in Civil Engineering

C. Liua, J.D. Yeagera & K.J. Ramosa (2015 ) Bonding energy of Sylgard on fused quartz: an experimental investigation Philosophical Magazine

Stephen G. Newman , Kyoungmi Lee , Jianghuai Cai , Lu Yang , William H. Green , and Klavs F. Jensen (2014 ) Continuous Thermal Oxidation of Alkenes with Nitrous Oxide in a Packed Bed Reactor Industrial & Engineering Chemisrty Research

Jinyoung Baekm Dr. Peter M. Allen, Prof. Moungi G. Bawendi & Prof. Klavs F. Jensen (2010 ) Investigation of Indium Phosphide Nanocrystal Synthesis Using a High-Temperature and High-Pressure Continuous Flow Microreactor Angwandte Chemie

I. R. G. Ogilvie, V. J. Siebe, M. C. Mowlem, and H. Morgan (2011 ) Temporal Optimization of Microfluidic Colorimetric Sensors by Use of Multiplexed Stop-Flow Architecture Analytical Chemistry

Isabella Pallotta, Ph.D., Michael Lovett, Ph.D., David L. Kaplan, Ph.D. & Alessandra Balduini, M.D. (2011 ) Three-Dimensional System for the In Vitro Study of Megakaryocytes and Functional Platelet Production Using Silk-Based Vascular Tubes Tissue Engineering

Laurent Pellegatti and Stephen L. Buchwald (2012 ) Continuous-Flow Preparation and Use of β-Chloro Enals Using the Vilsmeier Reagent Organic Process Research & Development