array(3) { ["show"]=> bool(true) ["ip"]=> string(11) "57.141.5.13" ["country"]=> string(2) "US" } desde la funcion de ip obtenemos IP invalida
harvardapparatus.com is a data controller for the purposes of the General Data Protection Regulation ("GDPR"). By proceeding to tick the consent box at right, you consent to harvardbioscience.com processing your personal data, under the GDPR and any other applicable legislation, that we collect from you in accordance with our Privacy Policy. If you wish to withdraw your consent for us to process your personal data please contact our Compliance Team. Please address any questions, comments and requests (including your right to withdraw your consent to process your personal data) regarding our data processing practices to our Compliance Team.
Allow

Neuro Amplifier EX

Price on Request
SKU
c0e550a7
The Neuro Amp EX (MLT185) is a low noise and high gain device which makes it suitable for all recording environments requiring a wide bandpass (100 Hz to 5 kHz) and a high signal to noise ratio. Animal applications include extracellular recordings from single cells or groups of cells single nerve fiber recordings (split-nerve preparation or human microneurography).
Grouped product items
Item No. Description Qty
No options of this product are available.

The Neuro Amp EX (MLT185) is a low noise and high gain device which makes it suitable for all recording environments requiring a wide bandpass (100 Hz to 5 kHz) and a high signal to noise ratio. Animal applications include extracellular recordings from single cells or groups of cells single nerve fiber recordings (split-nerve preparation or human microneurography).

The Neuro Amp EX headstage (included) provides a gain of 100x with a 10Hz High Pass filter. The cable shielding is directly connected to the casing, limiting the need for additional shielding at the input terminals. The device is certified safe for human connection with the supplied MLT185 Neuro Amp EX headstage.

The Neuro Amp EX is also supplied with six male (6) Amphenol connectors for customization of microelectrode adapters for use with the MLT185 Neuro Amp EX Headstage (microelectrodes are not supplied).

The Neuro Amp EX in Conjunction with PowerLab, LabChart or Scope Provides:

  • Full electrical isolation from power-line (mains) circuitry to guarantee subject safety 
  • A low-noise, high-gain differential amplifier specifically designed for recording extracellular potentials
  • Software-controlled low-pass, high-pass, notch and mains filters to remove unwanted signal frequencies for particular uses
  • Audio output to listen to neural signals. 

 Please note that the Neuro Amp EX is not suitable for intracellular recording with glass microelectrodes.

Specifications77-025377-0030
CertificationsCE*naCE
Control PortI²C Port Provides control and power. Interface communications rate of ~50 Kbits/s*na
Dimensions H x W x D English2.2 x 4.7 x 10.2 in*na
Dimensions H x W x D Metric55 x 240 x 260 mm*na
Filtering High Pass FilterFourth-order Bessel filter, ± 3% accuracy, frequencies software-selectable: 100 Hz, 300 Hz, 500 Hz*na
Filtering Low Pass FilterFourth-order Bessel filter, ± 3% accuracy, frequencies software-selectable: 1 kHz, 2 kHz, 5 kHz*na
Filtering Notch FilterSecond-order filter, -32 dB attenuation; 50 or 60 Hz frequency (automatic sensing)*na
Input Amplification Ranges± 20 µV to ± 1 mV full scale in 6 steps (combined PowerLab, Neuro Amp EX front-end and headstage)*na
Input ConfigurationOne isolated differential channel with isolated ground reference*na
Input Connection TypeFive-pin Redel connector*na
Input GainRange, Resolution

1 mV, 500 nV

500 µV, 250 nV

200 µV, 100 nV

100 µV, 50 nV

50 µV, 25 nV

20 µV, 10 nV
*na
Input Impedance100 MΩSee product page for complete specifications
Input Isolation Rating4000 Vrms (50 Hz for 1 minute)*na
Input Isolation4000 Vrms (50Hz for 1 minute)*na
Input SafetyApproved to IEC60601-1 BF (body protection)*na
Maximum Power Needs~2 W*na
ModelFE185MLT185
Operating Conditions5 to 35 °C, 0 to 90% humidity (non-condensing)*na
Output Analog Signal±2.0 V standard*na
Output AudioStereo jack with mono output; ± 200 mV full scale, current limited to ± 5 mA, suitable for headphones or powered speakers.*na
Package11
Product FamilyData AcquisitionData Acquisition
Weight English2 lb 13 oz*na
Weight Metric1.3 kg*na