Millar Ventri-Cath Multi-Segment Pressure-Volume Loop Catheters for Dogs, Pigs and Sheep

Millar Ventri-Cath Multi-Segment Pressure-Volume Loop Catheters for Dogs, Pigs and Sheep

These catheters combine pressure sensors and electrodes for simultaneous high fidelity pressure and volume measurements with MPVS Ultra Pressure-Volume Systems., enabling minimally invasive, continuous, intracardiac pressure-volume analysis. PV models feature a high torque catheter body and range in size from 5 to 6 French in single-field or dual-field configurations, with closed-end pigtails. These catheters are all made of nlyon, have a straight or pigtail tip. and a combined PV pressure connector.

Abbreviations Used in Item Listing:

PV = pressure-volume
MS = multi-segment
F = French
E = number of electrodes
DField = dual field
SP = electrode spacing
L = length
PI = polyimide
Ny = nylon (material)
Str = straight (tip type)
Pigtail = pigtail (tip type)

Item# Description U.S. List Price Quantity
No options of this product are available.
Login for U.S. Pricing


Millar Instruments manufactures and markets a line of combination Pressure-Volume (PV) catheters for use with MPVS Ultra Pressure-Volume Systems. These catheters combine pressure sensors and electrodes for simultaneous high fidelity pressure and volume measurements, enabling minimally invasive, continuous, intracardiac pressure-volume analysis. PV models feature a high torque catheter body and range in size from 5 to 6 French in single-field or dual-field configurations, with closed-end pigtails. Model configurations include the availability of a second pressure sensor, and as many as 12 electrodes. Electrode spacing varies to accommodate a range of applications. These catheters are all made of nlyon, have a straight or pigtail tip. and a combined PV pressure connector.

• High Torque Catheter Body
• 2 to 6 French size in single- or dual-field configuration
• Pressure and volume measurement from a single instrument
• Multi-Segment to ensure accurate volume measurement in hearts of varying sizes
• High frequency response
• Pressure measurement at the source
• No motion artifact or damping of pressure signal
• For use with Millar MPVS Ultra Pressure Volume Systems

Mllar also offers Pressure-Volume catheters configured for an apical approach. Please contact Harvard Apparatus Technical Support to select the appropriate catheter and interface cable.

NOTE: These catheters require a the MPVS Ultra Multi-Segment Control Unit as well as the appropriate interface cables to your selected data acquisition system. Please contact Harvard Apparatus Technical Support if you would like assistance in selecting the appropriate electrode and monitor cables. These catheters are warranted for five uses or sixty days, whichever occurs first and are not repairable.

 

 

High Torque Catheter Body   2 to 6 French size in single- or dual-field configuration   Pressure and volume measurement from a single instrument   Multi-Segment to ensure accurate volume measurement in hearts of varying sizes   High frequency response   Pressure measurement at the source   No motion artifact or damping of pressure signal   For use with Millar MPVS Ultra Pressure Volume Systems Millar Instruments manufactures and markets a line of combination Pressure-Volume (P-V) catheters for use with its pressure-volume system, MPVS Ultra. These catheters combine pressure sensors and electrodes for simultaneous high fidelity pressure and volume measurements, enabling minimally invasive, continuous, intracardiac pressure-volume analysis. P-V models feature a high torque catheter body and range in size from 5 to 6 French in single-field or dual-field configurations, with closed-end pigtails. Model configurations include the availability of a second pressure sensor, and as many as 12 electrodes. Electrode spacing varies to accommodate a range of applications.   Millar also offers Pressure-Volume catheters configured for an apical approach. Please contact Harvard Apparatus Technical Support to select the appropriate catheter and interface cable.   NOTE: These catheters require a the MPVS Ultra Multi-Segment Control Unit as well as the appropriate interface cables to your selected data acquisition system. Please contact Harvard Apparatus Technical Support if you would like assistance in selecting the appropriate electrode and monitor cables. These catheters are warranted for five uses or sixty days, whichever occurs first and are not repairable.