array(3) { ["show"]=> bool(true) ["ip"]=> string(14) "193.233.83.232" ["country"]=> string(2) "US" } desde la funcion de ip obtenemos IP invalida
harvardapparatus.com is a data controller for the purposes of the General Data Protection Regulation ("GDPR"). By proceeding to tick the consent box at right, you consent to harvardbioscience.com processing your personal data, under the GDPR and any other applicable legislation, that we collect from you in accordance with our Privacy Policy. If you wish to withdraw your consent for us to process your personal data please contact our Compliance Team. Please address any questions, comments and requests (including your right to withdraw your consent to process your personal data) regarding our data processing practices to our Compliance Team.
Allow

CMA 120 System for Freely Moving Animals

Price on Request
In stock
SKU
620a9c9e

The CMA 120 System for Freely Moving Animals enables microdialysis studies on conscious, small laboratory animals over long periods of time.

  • Balance arm with dual channel swivel
  • Secures tubing away from the animal and prevents twisting

Grouped product items
Item No. Description Qty
CMA8309049 CMA 120 System for Freely Moving Animals Please login to add to Quote
CMA8309672 CMA 120 Bowl with Food and Water Containers (Height 360 mm, Diameter 400 mm) Please login to add to Quote
CMA8309031 CMA 120 Plastic Bowl (Height 360 mm, Diameter 400 mm) Please login to add to Quote
CMA8309048 CMA 120 Complete Swivel Assembly Please login to add to Quote
CMA2409090 CMA 120 Swivel Assembly without Swivel Please login to add to Quote
CMA2409051 CMA 120 Wire Set with Collar Connector Please login to add to Quote
CMA8309032 CMA 120 Balance Arm Please login to add to Quote
CMA8002714 CMA 120 Swivel Pin and Gimbal Please login to add to Quote
CMA2409069 CMA 120 Plastic Vial Holder Please login to add to Quote
CMA2409091 CMA 120 Wire Attachment Please login to add to Quote
CMA7431059 Plastic Animal Collar (pkg. of 100) Please login to add to Quote
CMA3409500 Tubing Adapters for CMA Microdialysis Probes, pkg. of 10 Please login to add to Quote
CMA3409501 FEP Tubing, 0.12 mm ID, 1 m (pkg. of 1) Please login to add to Quote
CMA8409501 FEP Tubing, 0.12 mm ID, 1 m (pkg. of 10) Please login to add to Quote
CMA8309046 CMA 120 Instrument Table Please login to add to Quote

The CMA 120 System for Freely Moving Animals enables microdialysis studies on conscious, small laboratory animals over long periods of time.

CMA 120 System for Freely Moving Animals includes:

  • CMA 120 plastic bowl
  • CMA 120 swivel assembly
  • CMA 120 balance arm
  • Plastic collar (100 pcs)
  • Tubing adapters (10 pcs)
  • FEP tubing (1 m)
  • Vial, plastic 300 μl (25 pcs)
  • Caps, plastic (25 pcs)

The CMA 120 instrument can be used in combination with any one of the microdialysis systems. The microdialysis probe is attached to a CMA Syringe Pump, the CMA 110 Liquid Switch, and to any of the CMA 142 or CMA 470 collection devices via a dual channel swivel.

The swivel is mounted on the balancing arm allowing free movement of the animal. The swivel brace holds a wire with a collar connector and two holders for 300 µl plastic vials.

The wire attached to the animal collar turns the swivel and supports the tubing. Manual fraction collection is used when two microdialysis probes are implanted, or when microdialysis is combined with local injection via one channel of the swivel.

The CMA 120 Bowl with Food and Water Containers is used in studies where a freely moving animal will be contained for longer periods of time. The additions of these containers allow the animal to feed and drink ad libitum. The food container and water bottle are arranged on the outside of the bowl so as not to disturb the movement of the tethered animal when inside the bowl.

Both containers are easily removed for cleaning and refilling.

Keeler GD, Durdik JM, Stenken JA. (2015 ) Effects of delayed delivery of dexamethasone-21-phosphate via subcutaneous microdialysis implants on macrophage activation in rats. Acta Biomater.

Yau JL, Noble J, Kenyon CJ, Ludwig M, Seckl JR. (2015 ) Diurnal and stress-induced intra-hippocampal corticosterone rise attenuated in 11β-HSD1-deficient mice: a microdialysis study in young and aged mice. Eur J Neurosci.

Fangfang Wanga, Shijuan Zhanga*, Cuncun Shenga, Xian’en Zhaoa & Jinmao Youab* (2015 ) Sensitive Determination of Amantadine in Microdialysis Samples from Rat Plasma by HPLC with Fluorescence Detection Journal of Liquid Chromatography & Related Technologies