- Page 2 - Page 3 - Page 4 - Page 5 - Page 6 - Page 7 - Page 8 - Page 9 - Page 10 - Page 11 - Page 12 - Page 13 - Page 14 - Page 15 - Page 16 - Page 17 - Page 18 - Page 19 - Page 20 - Page 21 - Page 22 - Page 23 - Page 24 - Page 25 - Page 26 - Page 27 - Page 28 - Page 29 - Page 30 - Page 31 - Page 32 - Page 33 - Page 34 - Page 35 - Page 36 - Page 37 - Page 38 - Page 39 - Page 40 - Page 41 - Page 42 - Page 43 - Page 44 - Page 45 - Page 46 - Page 47 - Page 48 - Page 49 - Page 50 - Page 51 - Page 52 - Page 53 - Page 54 - Page 55 - Page 56 - Page 57 - Page 58 - Page 59 - Page 60 - Page 61 - Page 62 - Page 63 - Page 64 - Page 65 - Page 66 - Page 67 - Page 68 - Page 69 - Page 70 - Page 71 - Page 72 - Page 73 - Page 74 - Page 75 - Page 76 - Page 77 - Page 78 - Page 79 - Page 80 - Page 81 - Page 82 - Page 83 - Page 84 - Page 85 - Page 86 - Page 87 - Page 88 - Page 89 - Page 90 - Page 91 - Page 92 - Page 93 - Page 94 - Page 95 - Page 96 - Page 97 - Page 98 - Page 99 - Page 100 - Flash version © UniFlip.com |
Analgesia
NEW Dynamic Plantar Anesthesiometer
The Dynamic Plantar Aesthesiometer has been designed to automate the assessment of “touch sensitivity” on the plantar surface of rats or mice and comes ready to work with both Mice and Rats. It is known by some as the Electronic Von Frey or Plantar Von Frey instrument, but differently from Von Frey devices, Latency time, and Actual Force at the time of paw withdrawal reflex are automatically detected and recorded. The Dynamic Plantar Anesthesiometer consists of a movable force-actuator below a network platform upon which the operator deposits the rodent. A Perspex enclosure renders the animal unrestrained for the duration of the experiment.
key features
Analgesia • Dynamic Plantar Anesthesiometer
} Automatic detection of paw withdrawal (no visual
score needed!) (force ramp)
} Consistent application of force at an adjustable rate } Software included as standard } Data portability via the included memory key } NEW: orofacial stimulation by optional holders
The operator places the actuator beneath the paw (proper placement ensured via an angled mirror) and the actuator confers a use-defined force on a Von Frey-type filament. The filament exerts an increasing force to the plantar surface, starting below the threshold of detection and increasing until the animal removes its paw. At the retraction reflex movement when the paw is withdrawn, the registers and displays the actual force at which paw withdrawal occurred.
Specifications
force range force increasing rate filament travel Latency time connection to Pc 0 to 50.0 grams, in 0.5g steps adjustable in the interval 1 to 20 seconds, in 1 s steps 12 mm on graphic display, in 0.1s steps through DeLta 9-pin connector
Ordering Information
Order # 72-6704 Model 37450 Product Dynamic Plantar Anesthesiometer