Left Ventricular Pressure (LVP) Measurement Option for IH-SR and IH-5 Working Heart

Left Ventricular Pressure (LVP) Measurement Option for IH-SR and IH-5 Working Heart

Easily allows introduction of a tip pressure catheter directly into the left ventricle via the adapter port and the aorta, rather than via apical puncture.

To ensure that your system is properly configured as a functional unit that meets your application needs, please complete our Checklist and then contact Technical Services at 800-547-6766 or via email at support@hbiosci.com before placing an order. In Europe, please call +49 7665 92000 or via email at sales@hugo-sachs.de. Upgrades can also be modified to meet your specific needs.

Item# Description U.S. List Price Quantity
73-4037 Left Ventricular Pressure (LVP) Measurement Option in Mouse Working Heart (IHSR-WH-LVPM)
73-4038 Left Ventricular Pressure (LVP) Measurement Option in Rat/Guinea Pig Working Heart (IH-WH-LVPR)
Login for U.S. Pricing


Easily allows introduction of a tip pressure catheter directly into the left ventricle via the adapter port and the aorta, rather than via apical puncture. The IH-Series includes a specialized pathway which easily allows introduction of a tip pressure catheter directly into the left ventricle via the adapter port and the aorta, rather than via apical puncture.

The tip pressure catheter is connected using a dedicated connecting cable to a PLUGSYS TAM-A Transducer Amplifier Module.

Options

IHSR-WH-LVPM LVP Measurement in Mouse Working Heart (73-4037) includes: IHSR-WH-LVPR LVP Measurement in Rat/Guinea Pig Working Heart (73-4038) includes:
73-4193 Adapter for inserting tip catheter, small temperature probe or PE catheter into left ventricle via aortic cannula (Touhy Borst Adapter)
73-4193 Adapter for inserting tip catheter, small temperature probe or PE catheter into left ventricle via aortic cannula (Touhy Borst Adapter)
72-9781 Ultra-Miniature Pressure Transducer for Mouse, Model SPR 1000, Sensor Type 1.0F
72-9775 Ultra-Miniature Pressure Transducer for Rat, Model SPR 407, Main Size 1.5 F, Catheter Length 140 cm, Straight tip, Sensor Type 2F
72-9843 HEC-10D Pressure Catheter with Low Profile Connector to PLUGSYS TAM Amplifier
72-9842 Connection cable from Catheter to PLUGSYS TAM, Viking
73-0065
Transducer Amplifier Module (TAM A)
73-0065
Transducer Amplifier Module (TAM A)

IHSR-WH-LPVR (73-4038) can be used with both a functional IH-SR Working Heart system and a functional IH-5 Working Heart system. Additional catheter sizes are available for rat and guinea pig for IH-5. Please contact our technical team for help in choosing the correct catheter.

Important Note: If you plan to work with multiple species, please do not order both Options (73-4037 and 73-4038), as you will then receive duplicate items unnecessarily. Please contact us and we will quote only the additional items you will need.

Specifications