Homeothermic Controlled Operating Tables

Size 1 Homeothermic Operating Table flat bottom base for Mice

Homeothermic Controlled Operating Tables (size 1 for mouse and size 5 for rodent) have a heating, homeothermic temperature controller and consist of three parts: a probe, a control unit and an adaptor box. The control temperature is preset at 37°C at the factory and can be adjusted from 35° to 40°C by means of a control on the front panel.

  •  For general surgical work on small animals (mouse, rat, and guinea pig)
  • Choice of:
    • Tripod stand, flat-bottom or flat-angled mounting base
    • Size 1 for mouse or Size 5 for rodent
  • Capable of receiving thorax retractors and mounting ball joint holders
  • Includes four paw holders

 

Item# Description U.S. List Price Quantity
73-4231 Operating Table, Size 1, Tripod Stand, Homeothermic, 115 VAC
73-4233 Operating Table, Size 1, Tripod Stand, Homeothermic, 230 VAC
73-4232 Operating Table, Size 1, Flat-angled Stand, Homeothermic, 115 VAC
73-4234 Operating Table, Size 1, Flat-angled Stand, Homeothermic, 230 VAC
73-4916 Operating Table, Size 1, Flat Bottom Stand, Homeothermic, 115 VAC, Ultra Low Noise
73-4900 Operating Table, Size 1, Flat Bottom Stand, Homeothermic, 230 VAC, Ultra Low Noise
73-3975 Operating Table, Size 5, Tripod Stand, Homeothermic, 115 VAC
73-3979 Operating Table, Size 5, Tripod Stand, Homeothermic, 230 VAC
73-3976 Operating Table, Size 5, Flat-angled Stand, Homeothermic, 115 VAC
73-3980 Operating Table, Size 5, Flat-angled Stand, Homeothermic, 230 VAC
73-4917 Operating Table, Size 5, Flat Bottom Stand, Homeothermic, 115 VAC, Ultra Low Noise
73-4901 Operating Table, Size 5, Flat Bottom Stand, Homeothermic, 230 VAC, Ultra Low Noise
Login for U.S. Pricing


Homeothermic Controlled Operating Tables (size 1 for mouse and size 5 for rodent) have a heating, homeothermic temperature controller and consist of three parts: a probe, a control unit and an adaptor box. The control temperature is preset at 37°C at the factory and can be adjusted from 35° to 40°C by means of a control on the front panel.

  •  For general surgical work on small animals (mouse, rat, and guinea pig)
  • Choice of:
    • Tripod stand, flat-bottom or flat-angled mounting base
    • Size 1 for mouse or Size 5 for rodent
  • Capable of receiving thorax retractors and mounting ball joint holders
  • Includes four paw holders

The core components consist of a plate and mounting base. Both sides of the plate have multiple slots for fixing the spring-loaded paw clamps and optional thorax retractors. Numerous slots allow both large and small animals to be held firmly in position for optimal surgical access. A block clamp with ball joint holder can be fixed onto the plate for holding various probes, electrodes, or cannulae. A 4 mm banana plug outlet is available when grounding the table is required, (e.g. for ECG recordings).

Choice of mounting bases. The traditional tripod mounted base on a ball joint allows the table to tilt in multiple directions. The flat-angled base offers a lower profile requiring less working height.

Probe

The flexible probe is a precision thermistor encapsulated in a bead of epoxy resin at the top of a flexible hollow plastic tube. The 1.6 mm diameter probe is 100 mm (4 in) long and has a 2 m (6 ft) long cable with plug for attachment to the control unit. It is suitable for a wide range of laboratory animals from adult mice to rats and guinea pigs.

The output of the temperature sensing probe is used by the control unit to proportionally control the regulated, low-voltage DC supply to the operating table. This method of control alleviates the interference problems associated with that of non-proportional control, found with high-gain recording systems.

Control Unit

The control temperature is preset at 37°C at the factory and can be adjusted from 35° to 40°C by means of a control on the front panel. An LCD display on the control unit continuously displays the probe temperature. A horizontal LED bar graph indicates the level of power being delivered to the operating table. When core temperature is substantially below the desired temperature, the bar graph will indicate maximum power being delivered.

Adapter

The adapter consists of a separate box, which includes the permanent control of the operating table’s maximum temperature. It acts as a safety circuit by limiting the maximum temperature of the operating table to 40°C. This circuit uses a second thermistor probe built into the operating table.

Operating Table

The operating table is electrically floating, with respect to ground. However, one end of the heating element can be grounded by a switch on the front panel of the control unit. Special circuitry eliminates electrical noise thus permitting sensitive recordings.

Specifications