harvardapparatus.com is a data controller for the purposes of the General Data Protection Regulation ("GDPR"). By proceeding to tick the consent box at right, you consent to harvardbioscience.com processing your personal data, under the GDPR and any other applicable legislation, that we collect from you in accordance with our Privacy Policy. If you wish to withdraw your consent for us to process your personal data please contact our Compliance Team. Please address any questions, comments and requests (including your right to withdraw your consent to process your personal data) regarding our data processing practices to our Compliance Team.
Allow

High Grade Isotonic Transducer for PowerLab

Price on Request
SKU
a256dc88
The MLT0015 High Grade Isotonic Transducer measures isotonic contractions, that is the measurement of displacements without changes in force. The transducer connects to any ADInstruments Bridge Amp. (except ML118 Quad or ML119 Octal Bridge Amps). The MLT0015 High Grade Isotonic Transducer is suitable for isolated tissue studies and has been designed for operation with our range of organ bath models.
Grouped product items
Item No. Description Qty
No options of this product are available.

The MLT0015 High Grade Isotonic Transducer measures isotonic contractions, that is the measurement of displacements without changes in force. The transducer connects to the ML142 GP Amp or any ADInstruments Bridge Amp. (except ML118 Quad or ML119 Octal Bridge Amps). The MLT0015 High Grade Isotonic Transducer is suitable for isolated tissue studies and has been designed for operation with our range of organ bath models.


Operation:

Mount the transducer by its support rod with the scale on the lever arm facing upwards. Without applying any force to the lever arm, use the adjusting screw to balance the arm when the counterweight is positioned at the rotation centre. Attach the muscle using thread to one of the holes along the arm. The load can be balanced by moving the counterweight in the direction of the scale printed on the arm. This is achieved by turning the screw at the end of the lever arm. If the muscle is attached to the outermost hole on the arm, the scale can be read directly. Forces greater than 5 g can be measured by attaching the muscle to one of the more inner holes along the lever arm. In this case, multiply the reading on the scale by a factor of 90/d where d is the distance in mm from the rotation centre to the hole where the muscle is attached. Lines indicating weight on the scale are nominal and not supposed to be accurate.

Application:

The MLT0015 High Grade Isotonic Transducer is suitable for isolated tissue studies and has been designed for operation with our range of organ bath models.
Specifications77-0060
Amplification Input AmplifierSee product page for complete specifications
Body Diameter English1.14 in
Body Diameter Metric29 mm
Body Length English2.17 in
Body Length Metric55 mm
Cable Length English6.56 ft
Cable Length Metric2 m
Connector8-pin DIN
Counterweight Scale0 ? 5 g with 1 g divisions and 250 mg subdivisions
Counterweight11 g
Displacement Range±15° (0 ? 30°) equivalent to ±24 mm (0 ? 48 mm)
Excitation10 V DC nominal (12 V DC max.)
Frequency Range0 - 15 Hz with an organ attached
Input Resistance1 KΩ
Lever Length90 mm (3.5 in) with 7 fixation points at 10 mm (0.39 in) intervals. The first point is 30 mm (1.18 in) from the rotation centre.
Lever Weight2 g
Linearity0.5 % from base of the scale in the lever displacement range
ModelMLT0015
Output1.5 mV (corresponding to 20° in lever displacement)
Package1
Product FamilyData Acquisition
Resolution5 mg
Support Rod Diameter Metric0.24 in
Support Rod Length Metric5.9 in