Heated Fixed Temperature Operating Tables
The heated fixed temperature operating tables (size 1 for mice and size 5 for rodents) have a built-in heating transformer and temperature probe to ensure the temperature of the table is maintained.
Two different versions of the heated operating table are available depending on the level of temperature control required. These models are often used for quick surgical procedures or acute animal studies (30 minutes or less) requiring the core temperature of the animal be maintained but not tightly controlled.
- Two different mounting bases available: tripod base or flat angled base
- Choice of heating power supply or heating controller
- Includes 4 paw holders
- Capable of receiving thorax retractors and mounting ball joint holders
The heated fixed temperature operating tables (size 1 for mice and size 5 for rodents) have a built-in heating transformer and temperature probe to ensure the temperature of the table is maintained.
Two different versions of the heated operating table are available depending on the level of temperature control required. These models are often used for quick surgical procedures or acute animal studies (30 minutes or less) requiring the core temperature of the animal be maintained but not tightly controlled.
- Two different mounting bases available: tripod base or flat angled base
- Choice of heating power supply or heating controller
- Includes 4 paw holders
- Capable of receiving thorax retractors and mounting ball joint holders
The core components consist of a 300 x 185mm (11.8 x 7.3 in) anodized aluminum plate and mounting base. Both sides of the plate have multiple slots for fixing the spring-loaded paw clamps and optional thorax retractors. Numerous slots allow both large and small animals to be held firmly in position for optimal surgical access. A block clamp with ball joint holder can be fixed onto the plate for holding various probes, electrodes, or cannulae. A 4 mm banana plug outlet is available when grounding the table is required, e.g. for ECG recordings.
Two different models of the mounting base are available:
- Traditional tripod stand mounted on a ball joint allowing the table to tilt in multiple directions
- Flat angled version with a lower profile consuming less working height.
The fixed temperature heated models use feedback control from the built-in table temperature probe. The table can be heated and maintained up to 40oC but no adjustment to the amount of heat or heating rate is available.
Specifications | 73-3584 | 73-3582 | 73-3586 | 73-3585 |
---|---|---|---|---|
Heater Power | 20 | 20 | 20 | 20 |
Heater Voltage | 12 | 12 | 12 | 12 |
Heating Controller Depth English | 4.1 | 4.1 | 4.1 | 4.1 |
Heating Controller Depth Metric | 105 | 105 | 105 | 105 |
Heating Controller Height English | 8.3 | 8.3 | 8.3 | 8.3 |
Heating Controller Height Metric | 210 | 210 | 210 | 210 |
Heating Controller Power Output | 40 | 40 | 40 | 40 |
Heating Controller Supply Frequency | 50–60 | 50–60 | 50–60 | 50–60 |
Heating Controller Supply Voltage | 230, can be switched to 115 | 230, can be switched to 115 | 230, can be switched to 115 | 230, can be switched to 115 |
Heating Controller Voltage Output | 24 | 24 | 24 | 24 |
Heating Controller Weight English | 5.5 | 5.5 | 5.5 | 5.5 |
Heating Controller Weight Metric | 2.5 | 2.5 | 2.5 | 2.5 |
Heating Controller Width English | 6.1 | 6.1 | 6.1 | 6.1 |
Heating Controller Width Metric | 155 | 155 | 155 | 155 |
Heating Element | PTC resistor for approx. 40 | PTC resistor for approx. 40 | PTC resistor for approx. 40 | PTC resistor for approx. 40 |
Heating Plug-Transformer Construction | Protected against touching conforming to IEC 742 (VDE 0551). Unit is safety isolated | Protected against touching conforming to IEC 742 (VDE 0551). Unit is safety isolated | Protected against touching conforming to IEC 742 (VDE 0551). Unit is safety isolated | Protected against touching conforming to IEC 742 (VDE 0551). Unit is safety isolated |
Heating Plug-Transformer Mains Voltage | 230 V/50 Hz, 115 V/60 Hz to special order | 230 V/50 Hz, 115 V/60 Hz to special order | 230 V/50 Hz, 115 V/60 Hz to special order | 230 V/50 Hz, 115 V/60 Hz to special order |
Heating Plug-Transformer Secondary Voltage | 12 Volt, 20 VA for table temperature of approximately 40 | 12 Volt, 20 VA for table temperature of approximately 40 | 12 Volt, 20 VA for table temperature of approximately 40 | 12 Volt, 20 VA for table temperature of approximately 40 |
Heating Plug-Transformer Weight English | 1.5 | 1.5 | 1.5 | 1.5 |
Heating Plug-Transformer Weight Metric | 0.7 | 0.7 | 0.7 | 0.7 |
Material | Anodized Aluminum | Anodized Aluminum | Anodized Aluminum | Anodized Aluminum |
Table Height with Ball Joint English | 5.7 to 6.3 | 5.7 to 6.3 | 5.7 to 6.3 | 5.7 to 6.3 |
Table Height with Ball Joint Metric | 145 to 160 | 145 to 160 | 145 to 160 | 145 to 160 |
Table Height without Ball Joint English | Adjustable 3.0 to 3.7 | Adjustable 3.0 to 3.7 | Adjustable 3.0 to 3.7 | Adjustable 3.0 to 3.7 |
Table Height without Ball Joint Metric | Adjustable 75 to 95 | Adjustable 75 to 95 | Adjustable 75 to 95 | Adjustable 75 to 95 |
Table Length English | 11.8 | 11.8 | 11.8 | 11.8 |
Table Length Metric | 300 | 300 | 300 | 300 |
Table Weight English | 6.6 | 6.6 | 6.6 | 6.6 |
Table Weight Metric | 3 | 3 | 3 | 3 |
Table Width English | 7.3 | 7.3 | 7.3 | 7.3 |
Table Width Metric | 185 | 185 | 185 | 185 |