CMA 11 Microdialysis Probes

CMA 11 Microdialysis Probes

NEW CMA 11 PROBE FOR BIG MOLECULES!

Ideal for discrete areas in the CNS due to its greater spatial resolution and reduced size. Causes less tissue damage than other probe types.

  • Small diameter
  • High spatial resolution
  • Causes minimal tissue damage
  • Low internal volume
  • Membrane lengths: 1, 2, 3 or 4 mm
  • Membrane diameter: 0.24 mm (6 kDa), 0.26 mm (55 kDa) or 0.28 mm (500 kDa or 2 MDa)
  • Available metal free or β-irradiated

Item# Description U.S. List Price Quantity
CMA8309581 CMA 11 6 kDa Microdialysis Probe, 1 mm membrane length (pkg. of 3)
CMA8309582 CMA 11 6 kDa Microdialysis Probe, 2 mm membrane length (pkg. of 3)
CMA8309583 CMA 11 6 kDa Microdialysis Probe, 3 mm membrane length (pkg. of 3)
CMA8309584 CMA 11 6 kDa Microdialysis Probe, 4 mm membrane length (pkg. of 3)
CMA8011081 CMA 11 6 kDa Metal Free Microdialysis Probe, 1 mm membrane length (pkg. of 3)
CMA8011082 CMA 11 6 kDa Metal Free Microdialysis Probe, 2 mm membrane length (pkg. of 3)
CMA8011083 CMA 11 6 kDa Metal Free Microdialysis Probe, 3 mm membrane length (pkg. of 3)
CMA8011084 CMA 11 6 kDa Metal Free Microdialysis Probe, 4 mm membrane length (pkg. of 3)
CMA8011001 CMA 11 6 kDa β-Irradiated Microdialysis Probe, 1 mm membrane length (pkg. of 3)
CMA8011002 CMA 11 6 kDa β-Irradiated Microdialysis Probe, 2 mm membrane length (pkg. of 3)
CMA8011003 CMA 11 6 kDa β-Irradiated Microdialysis Probe, 3 mm membrane length (pkg. of 3)
CMA8011004 CMA 11 6 kDa β-Irradiated Microdialysis Probe, 4 mm membrane length (pkg. of 3)
CMA8012511 CMA 11 55 kDa Microdialysis Probe, 1 mm membrane length, pkg. of 3
CMA8012512 CMA 11 55 kDa Microdialysis Probe, 2 mm membrane length, pkg. of 3
CMA8012513 CMA 11 55 kDa Microdialysis Probe, 3 mm membrane length, pkg. of 3
CMA8012514 CMA 11 55 kDa Microdialysis Probe, 4 mm membrane length, pkg. of 3
CMA8012521 CMA 11 500 kDa Microdialysis Probe, 1 mm membrane length, pkg. of 3
CMA8012522 CMA 11 500 kDa Microdialysis Probe, 2 mm membrane length, pkg. of 3
CMA8012523 CMA 11 500 kDa Microdialysis Probe, 3 mm membrane length, pkg. of 3
CMA8012524 CMA 11 500 kDa Microdialysis Probe, 4 mm membrane length, pkg. of 3
CMA8012525 CMA 11 2 MDa Microdialysis Probe, 1 mm membrane length, pkg. of 3
CMA8012526 CMA 11 2 MDa Microdialysis Probe, 2 mm membrane length, pkg. of 3
CMA8012527 CMA 11 2 MDa Microdialysis Probe, 3 mm membrane length, pkg. of 3
CMA8012528 CMA 11 2 MDa Microdialysis Probe, 4 mm membrane length, pkg. of 3
Login for U.S. Pricing


NEW CMA 11 PROBE FOR BIG MOLECULES!

The CMA 11 Microdialysis Probe is ideal for discrete areas in the CNS due to its greater spatial resolution and reduced size. It causes less tissue damage than other probe types due to its small diameter.

The probe has a cuprophane membrane with an outside diameter of 0.24 mm. The outer steel shaft diameter is 0.38 mm. The inner cannula is constructed of fused silica coated with polyimid. The inlet/outlet capillaries are mounted in a white plastic body matched to the size of a corresponding guide cannula.

New CMA 11 microdialysis probes are now available with a 55 kDa cut-off and 0.26 mm outer diameter (more details in the Specifications section).

New CMA 11 microdialysis probes for big molecules are also now available with 500 kDa and 2 MDa cut-off, 0.28 mm outer diameter and 14 mm shaft length (more details in the Specifications section).

Once implanted, the probe sits tightly in the guide cannula´s capsule without the need for screwing or cementing. FEP tubing is connected to the probe using tubing adaptors.

Standard part numbers are available for metal free or β-irradiated CMA 11 6kDa probes.

For metal free or β-irradiated CMA 11 55 kDa, 500kDa and 2MDa probes, please make your request using our Custom Probe Form and send it to our Technical Support Team. We will contact you promptly.

CMA 11 Microdialysis Probes are guaranteed for single use.

SpecificationsCMA8309581CMA8309582CMA8309583CMA8309584CMA8011081CMA8011082CMA8011083CMA8011084CMA8011001CMA8011002CMA8011003CMA8011004CMA8012511CMA8012512CMA8012513CMA8012514CMA8012521CMA8012522CMA8012523CMA8012524CMA8012525CMA8012526CMA8012527CMA8012528
Membrane Length1 mm2 mm3 mm4 mm1 mm2 mm3 mm4 mm1 mm2 mm3 mm4 mm1 mm2 mm3 mm4 mm1 mm2 mm3 mm4 mm1 mm2 mm3 mm4 mm
Membrane O D0.24 mm0.24 mm0.24 mm0.24 mm0.24 mm0.24 mm0.24 mm0.24 mm0.24 mm0.24 mm0.24 mm0.24 mm0.26 mm0.26 mm0.26 mm0.26 mm0.28 mm0.28 mm0.28 mm0.28 mm0.28 mm0.28 mm0.28 mm0.28 mm
Membrane MaterialCuprophaneCuprophaneCuprophaneCuprophaneCuprophaneCuprophaneCuprophaneCuprophaneCuprophaneCuprophaneCuprophaneCuprophanePolyestersulfone (PES)Polyestersulfone (PES)Polyestersulfone (PES)Polyestersulfone (PES)Polyestersulfone (PES)Polyestersulfone (PES)Polyestersulfone (PES)Polyestersulfone (PES)Polyestersulfone (PES)Polyestersulfone (PES)Polyestersulfone (PES)Polyestersulfone (PES)
Molecular Weight Cut-off6 kD6 kD6 kD6 kD6 kD6 kD6 kD6 kD6 kD6 kD6 kD6 kD55 kD55 kD55 kD55 kD500 kD500 kD500 kD500 kD2 MDa2 MDa2 MDa2 MDa
Shaft Diameter0.40 mm0.40 mm0.40 mm0.40 mm0.40 mm0.40 mm0.40 mm0.40 mm0.40 mm0.40 mm0.40 mm0.40 mm0.40 mm0.40 mm0.40 mm0.40 mm0.40 mm0.40 mm0.40 mm0.40 mm0.40 mm0.40 mm0.40 mm0.40 mm
Shaft Length Metric14 mm14 mm14 mm14 mm14 mm14 mm14 mm14 mm14 mm14 mm14 mm14 mm14 mm14 mm14 mm14 mm14 mm14 mm14 mm14 mm14 mm14 mm14 mm14 mm
Inlet Volumenegligiblenegligiblenegligiblenegligiblenegligiblenegligiblenegligiblenegligiblenegligiblenegligiblenegligiblenegligible0.1 µL0.1 µL0.1 µL0.1 µL0.1 µL0.1 µL0.1 µL0.1 µL0.1 µL0.1 µL0.1 µL0.1 µL
Outlet Volume1 µL1 µL1 µL1 µL1 µL1 µL1 µL1 µL1 µL1 µL1 µL1 µL1 µL1 µL1 µL1 µL1 µL1 µL1 µL1 µL1 µL1 µL1 µL1 µL
ModelStandardStandardStandardStandardMetal FreeMetal FreeMetal FreeMetal Freeβ-Irradiatedβ-Irradiatedβ-Irradiatedβ-IrradiatedStandardStandardStandardStandardStandardStandardStandardStandardStandardStandardStandardStandard

Dahlberg D, Mariussen E, Goverud IL, Tønjum T, Mæhlen J, Antal EA, Hassel B. (2015 ) Staphylococcal α-hemolysin is neurotoxic and causes lysis of brain cells in vivo and in vitro Neurotoxicology.

Garrity AG, Botta S, Lazar SB, Swor E, Vanini G, Baghdoyan HA, Lydic R. (2015 ) Dexmedetomidine-induced sedation does not mimic the neurobehavioral phenotypes of sleep in sprague dawley rat. Sleep.

DOCUMENT DESCRIPTION
CMA 11 6kDa Microdialysis Probes Manual D000458F.pdfCMA 11 6 kDa Microdialysis Probe User's Manual
CMA 11 55kDa Microdialysis Probes Manual 8012510A.pdfCMA 11 55 kDa Microdialysis Probe User's Manual
8011683A CMA 11 500kDa & 2MD Microdialysis Probes Manual.pdfCMA 11 500 kDa & 2 mDa Microdialysis Probe User's Manual