array(3) { ["show"]=> bool(true) ["ip"]=> string(13) "217.113.194.3" ["country"]=> string(2) "FR" } desde la funcion de ip obtenemos IP invalida
harvardapparatus.com is a data controller for the purposes of the General Data Protection Regulation ("GDPR"). By proceeding to tick the consent box at right, you consent to harvardbioscience.com processing your personal data, under the GDPR and any other applicable legislation, that we collect from you in accordance with our Privacy Policy. If you wish to withdraw your consent for us to process your personal data please contact our Compliance Team. Please address any questions, comments and requests (including your right to withdraw your consent to process your personal data) regarding our data processing practices to our Compliance Team.
Allow

Activated Charcoal SpinColumns

Price on Request
SKU
GRP-Char-Spin

QuikPrep® SpinColumns™ with activated charcoal packing materials can be used for DNA, protein and peptide purification; small molecule, carbohydrate, salt and radiolabel removal; Nick translation; and affinity separation. Activated charcoal retains polar solutes. Salt will not be retained.

Grouped product items
Item No. Description Qty
74-4806 Micro SpinColumns, Activated Charcoal, Qty. of 24 Please login to add to Quote
74-4800 Micro SpinColumns, Activated Charcoal, Qty. of 96 Please login to add to Quote
74-4306 Macro SpinColumns, Activated Charcoal, Qty. of 24 Please login to add to Quote
74-4300 Macro SpinColumns, Activated Charcoal, Qty. of 96 Please login to add to Quote
74-5629 96-Well Micro SpinColumns, Activated Charcoal, 1.1 ml Reservoir Plate (1) Please login to add to Quote
74-5669 96-Well Macro SpinColumns, Activated Charcoal, 1.1 ml Reservoir Plate (1) Please login to add to Quote

QuikPrep® SpinColumns™ with activated charcoal packing materials can be used for DNA, protein and peptide purification; small molecule, carbohydrate, salt and radiolabel removal; Nick translation; affinity separation and buffer exchange. Activated charcoal retains polar solutes. Salt will not be retained.

Column Type Sample Volume Sample Capacity Suggested
Elution Volume
Included
Ultra-Micro  10 µl to 25 µl 3 to 30 µg
 28.5 µl

Two 2 ml centrifuge tubes with top caps

Micro  25 µl to 75 µl 5 to 60 µg
 50 µl
Two 2 ml centrifuge tubes with top caps
Macro  75 µl to 150 µl 30 to 300 µg
 143 µl
Two 2 ml centrifuge tubes with top and bottom caps
96-Well Micro  25 µl to 75 µl 5 to
60 µg
 50 µl
Two 96-well collection plates (1.1 ml per well)
96-Well Macro  25 µl to
150 µl
30 to
300 µg
 143 µl
Two 96-well collection plates (1.1 ml per well)