Welcome to Harvard Apparatus! — Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources
Shopping Cart
                     My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
Harvard Apparatus

GoDaddy
 

Home Standard Infuse/Withdraw PHD Ultra Syringe Pumps

 

Standard Infuse/Withdraw PHD Ultra Syringe Pumps


The PHD Ultra is the solution for your most demanding fluidics applications. This pump represents the latest technology in syringe pumps and was developed utilizing the feedback of the world's largest populations of syringe pump users.

The PHD Ultra will change the way you think about syringe pumps. There are three major areas which make the PHD Ultra the new standard for syringe pumps:

1. New - Patent pending mechanical drive mechanism and syringe holding mechanics to achieve the highest performance of any syringe pump

2. New - EZ PRO Software and user interface allow easy programming of methods from simple to complex, all without the use of a PC
- Preprogrammed methods for simple to complex operations that allow you to be up and running with the push of a button
- LCD, high resolution color touch screen for powerful functionality, yet easy to use

3. New levels of versatility
a. Configurations: push-pull, standard, remote, high pressure, multi racks
b. Connectivity: rs232 and USB for PC; RS 485for daisy chain.

Dimensions: 12.0 x 8.5 x 7.5 - compact design fits easily on your bench


Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
703006 PHD Ultra Syringe Pump Infuse/Withdraw Standard -- 5 days View Pricing
Login to Shop
703007 PHD Ultra Syringe Pump Infuse/Withdraw Programmable Yes -- View Pricing
Login to Shop
703008 PHD Ultra Syringe Pump with Push/Pull Mechanism -- 5 days View Pricing
Login to Shop
703009 PHD Ultra Syringe Pump with Push/Pull Mechanism Programmable -- 5 days View Pricing
Login to Shop
703020A PHD Ultra 6x10 MultiRack - when purchased with Pump -- 5 days View Pricing
Login to Shop
703021A PHD Ultra 4x140 MultiRack - when purchased with Pump -- 5 days View Pricing
Login to Shop
703022A PHD Ultra MicroDialysis MultiRack - when purchased with Pump -- 5 days View Pricing
Login to Shop
703033 PHD Ultra Analog Control Input Option (If needed, must be purchased at the same time as the Ultra Programmable Pump) -- 5 days View Pricing
Login to Shop
703030 PHD Ultra RS-232 RJ-11 Connectors Option (If needed, must be purchased at the same time as the Ultra Pump) -- 5 days View Pricing
Login to Shop
703034 PHD Ultra Internal Fan Option (Required if external operating ambient is >35°C. If needed, fan must be purchased at the same time as the Ultra Pump) -- 5 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

Features:
• New patent pending drive mechanism for unmatched smooth flow, accuracy and precision
• From picoliter to 220 ml/min flow rates
• Advanced programming for true multi methods without a PC
• Quick start methods
• Alpha/numeric keyboard without a PC
• Real and relative time clocks
• Icon operation
• New color LCD touch screen
• Up-front control knobs for ease of operation
• Vertical or horizontal orientation
• Adjustable linear force to 75 lbs across the entire flow range
• Daisy chain
• Remote configuration placement
• CE, CSA, UL, WEEE, EU RoHS, CB Scheme Approved
• 2 year warranty

Applications:
• Nanofluidics
• Drug/Nutritional infusions
• Electro-spinning
• Reaction chamber addition
• Mass Spec calibration
• Feeding cells
• Low pressure chromatography
• Continuous flow
• Flow programming
• Gradients
• % composition step changes
• Large flow deliveries
• I/O interactive experiments

The PHD Ultra is the solution for your most demanding fluidics applications. This pump represents the latest technology in syringe pumps and was developed utilizing the feedback of the world's largest populations of syringe pump users.

The PHD Ultra will change the way you think about syringe pumps. There are three major areas which make the PHD Ultra the new standard for syringe pumps:

1. New - Patent pending mechanical drive mechanism and syringe holding mechanics to achieve the highest performance of any syringe pump

2. New - EZ PRO Software and user interface allow easy programming of methods from simple to complex, all without the use of a PC
- Preprogrammed methods for simple to complex operations that allow you to be up and running with the push of a button
- LCD, high resolution color touch screen for powerful functionality, yet easy to use

3. New levels of versatility
a. Configurations: push-pull, standard, remote, high pressure, multi racks
b. Connectivity: rs232 and USB for PC; RS 485 for daisy chain

Harvard Apparatus introduces the next generation of syringe pumps, the PHD Ultra for the most demanding applications.

Since 1901 Harvard Apparatus has been supporting bioresearch fluidics requirements with the culmination being the introduction of the first commercial syringe pump for bioresearch in 1956. Since 1956, over 70,000 satisfied syringe pump users around the world have made Harvard Apparatus syringe pumps the worlds #1 choice.

The PHD Ultra Syringe Pump series is a family of high-accuracy, microliter- and milliliter-compatible pumps designed for versatile technical use including mass spectroscopy, calibration, drug and nutritional infusions, microdialysis, dispensing, chromatography and LC/HPLC.

Highest Accuracy and Precision
The PHD Ultra syringe pump family has a new patent pending fluidics drive mechanism which assures ease of use and high performance, for smoother, more accurate flow rates than any other syringe pump. Flow rates are accurate within 0.35% and reproducibility within 0.05%. A microprocessor-controlled, small step angle stepping motor drives a lead screw and pusher block. Advanced micro-stepping techniques are employed to further reduce the step angle to eliminate flow pulsation.

Advanced Programming Features:
• Flow Programming - Change the flow with time, volume or a triggered event as many times as you like
• Bolus - Inject a drug (or drugs) in a high quantity at once. The bolus injection can be made in time or volume.
• Concentration Delivery - Calibrate flow in concentration units of mg/kg easily so flow is calibrated to concentration of drug and animal weight.
• Gradients
• % ratio - up to three solvents
• I/O — dedicated and user defined I/O
• Pulsed Flow- so you can program the pulse easily

Widest Flow Rate Range
This pump is engineered to provide flow accuracy within 0.35% and reproducibility within 0.05%. Single or multi syringes from 0.5 µl to 140 ml pump at a range of 0.0001 µl/hr to 220 ml/min.

Maximum Experimental Versatility
The PHD Ultra features true Multi-Pump Operation. The pump can be oriented vertically or horizontally for optimum experimental connectivity. This pump comes standard to hold 2 syringes, but can be purchase with 3 other syringe racks: 6 to 10 syringe rack, 4 x 140ml syringe rack and 4 x microliter syringe rack.

Easy-to-Use Interface
The PHD Ultra color LCD touch screen graphic interface is divided into three basic areas: Operations Display, Message Area, and Navigation. This configuration allows you to easily move through all menu selections and data entry by gently touching the onscreen buttons with a finger or the tip of a soft, non-sharp object such as a pencil eraser.

The Methods Main or Quick Start screens are the primary ?home? for the applications. From those screens you access all the commands needed to operate the PHD Ultra, as well as the main system settings.

The Message Area of the touch screen is used to display helpful instructions for the currently displayed screen. It is also used to display error or warning messages to indicate problem conditions in a Method or error conditions during pump operation.

The software is organized into three main Navigational branches, the quick start operations, preloaded/user-defined Methods, and systems settings. You can control operations directly with the touch screen or remotely from an independent computer or device via the external I/O interface.

Program Description
To operate the PHD Ultra, the user defines all the required parameters for infusing or withdrawing liquids through a Pump Control Method. The basic operation is a simple 4-step procedure:

1. Select a method
2. Enter operating parameters
3. Preview your method
4. Run your method

Applications
• Animal Infusions or Withdrawals - The PHD Ultra will control the delivery of varying % of nutrients or drugs infused into animals, flush lines using catheters, needles, cannulae or microdialysis.
• Proportioning and Delivering of Mixtures - Mixing gradients or proportions with independent control of two liquids.
• Aerosol for Coating - The pump at high pressure can create an aerosol for the delivery of coating materials such as pharmaceutical tablets and aerosol studies.
• Delivery to Mass Spectroscopy - The delivery of fluids to the MS for calibration, matrix addition or ESI sample.
• Compensating Flows - The continuous infusion and simultaneous withdrawal of liquids for cell cultures or perfusion chambers.
• Dispensers/Injectors — Adhesives, Cell injection, MRI Dyes, Activators/Enzymes, Flow injection, Microreaction vessels, or Stereotaxic delivery.

Advanced GLP Documentation Features:
• Experiment parameter download information to PC
• Alpha/numeric capability

Pump Models
The PHD Ultra Syringe Pump is available in three configurations designed for different operating environments and varying degrees of operational flexibility.

1. Infuse Only: This model supports infusion operations at user-definable flow rates and with selectable target volume or time values to control the total infusion volume. The entry-level Infuse Only model does not include programmable, user-defined methods.

2. Infuse/Withdraw: This model supports infusion and withdraw operations at user-definable flow rates and with selectable target volumes or time values to control the total volume pumped for both the infusion and withdraw portions of a procedure. This model provides access to many of the advanced method programming options of the PHD Ultra, but only supports a single stored method.

3. Infuse/Withdraw Programmable: This model supports both infusion and withdraw operations and can use both simplified pumping profiles or the more advanced pump profiles and I/O settings that permit interactions with external devices. In addition to supporting all of the advanced programming tools available on the PHD Ultra, this model also allows users to create and store multiple user-defined methods on the pump.

Syringe Racks
The PHD Ultra is offered with a variety of syringe racks to meet your specific application.

Upgrade
We offer pumps that can be upgraded. If you buy an infuse/withdraw pump and later decide you want programmability you can upgrade it. You pay a lot less than buying a whole new pump. (pump must be returned to the factory for all upgrades)

Accessories
A full range of accessories are compatible with the PHD Ultra including syringe heaters, in-line heaters and coolers, nanofluidic circuits, connectors, tubing, syringes and more.

* Note: Fan option is required if external operating ambient is expected to be >35°C. If needed, fan must be purchased at the same time as the Ultra Pump.


Specifications Back to Top

Specifications703006703007703008703009703020A703021A703022A703033703030703034
Accuracy±0.35%±0.35%±0.35%±0.35%      
Catalog Page PDF          
ClassificationClass IClass IClass IClass I      
Dimensions Control Box LxDxH in cm 12.0 x 8.5 x 7.25 (30.48 x 21.59 x 18.42)12.0 x 8.5 x 7.25 (30.48 x 21.59 x 18.42)12.0 x 8.5 x 7.25 (30.48 x 21.59 x 18.42)12.0 x 8.5 x 7.25 (30.48 x 21.59 x 18.42)      
Dimensions Remote Box LxDxH in cm           
Display4.3" WQVGA TFT Color Display with Touchpad4.3" WQVGA TFT Color Display with Touchpad4.3" WQVGA TFT Color Display with Touchpad4.3" WQVGA TFT Color Display with Touchpad      
Drive Motor0.9° Stepper Motor0.9° Stepper Motor0.9° Stepper Motor0.9° Stepper Motor      
Environmental Humidity20% to 80% RH, non condensing20% to 80% RH, non condensing20% to 80% RH, non condensing20% to 80% RH, non condensing      
Environmental Operating Temperature English40°F to 104°F*40°F to 104°F*40°F to 104°F*40°F to 104°F*      
Environmental Operating Temperature Metric4°C to 40°C*4°C to 40°C*4°C to 40°C*4°C to 40°C*      
Environmental Storage Temperatue English14°F to 158°F14°F to 158°F14°F to 158°F14°F to 158°F      
Environmental Storage Temperatue Metric-10°C to 70°C-10°C to 70°C-10°C to 70°C-10°C to 70°C      
Flow Rate Maximum220.97 ml/min using 140 ml syringe220.97 ml/min using 140 ml syringe220.97 ml/min using 140 ml syringe220.97 ml/min using 140 ml syringe      
Flow Rate Minimum1.56 pl/min using 0.5 µl syringe1.56 pl/min using 0.5 µl syringe1.56 pl/min using 0.5 µl syringe1.56 pl/min using 0.5 µl syringe      
I/O & TTL Connectors15 pin D-Sub Connector15 pin D-Sub Connector15 pin D-Sub Connector15 pin D-Sub Connector      
Input Power50 W, 0.5 A fuse50 W, 0.5 A fuse50 W, 0.5 A fuse50 W, 0.5 A fuse      
Installation CategoryIIIIIIII      
Max Linear Force75 lbs @ 100% Force Selection75 lbs @ 100% Force Selection75 lbs @ 100% Force Selection75 lbs @ 100% Force Selection      
Mode of OperationContinuousContinuousContinuousContinuous      
Motor Drive ControlMicroprocessor with 1/16 microsteppingMicroprocessor with 1/16 microsteppingMicroprocessor with 1/16 microsteppingMicroprocessor with 1/16 microstepping      
Net Weight English10 lb10 lb10 lb10 lb      
Net Weight Metric4.5 kg4.5 kg4.5 kg4.5 kg      
No of Syringes22446 to 1044   
Non Volatile MemoryStorage of all settingsStorage of all settingsStorage of all settingsStorage of all settings      
Number of Microsteps per one rev of Lead Screw12,80012,80012,80012,800      
Pollution Degree1111      
Pump ConfigurationStandardStandardStandardStandard      
Pump FunctionInfuse/WithdrawInfuse/Withdraw, ProgrammableInfuse/WithdrawInfuse/Withdraw, Programmable      
Pusher Travel Rate Maximum190.8 mm/min190.8 mm/min190.8 mm/min190.8 mm/min      
Pusher Travel Rate Minimum0.18 µm/min0.18 µm/min0.18 µm/min0.18 µm/min      
RS 232 Connectors9 pin D-Sub Connector9 pin D-Sub Connector9 pin D-Sub Connector9 pin D-Sub Connector      
Regulatory CertificationsCE, UL, CSA, CB Scheme, EU RoHSCE, UL, CSA, CB Scheme, EU RoHSCE, UL, CSA, CB Scheme, EU RoHSCE, UL, CSA, CB Scheme, EU RoHS      
Reproducibility±0.05%±0.05%±0.05%±0.05%      
Step Rate Maximum26 µsec/µstep26 µsec/µstep26 µsec/µstep26 µsec/µstep      
Step Rate Minimum27.5 sec/µstep27.5 sec/µstep27.5 sec/µstep27.5 sec/µstep      
Syringe Rack TypeStandard RackStandard RackPush/Pull Syringe RackPush/Pull Syringe RackMulti-Syringe RackMulti-Syringe RackMulti-Syringe Rack   
Syringe Size Maximum140 ml140 ml140 ml140 ml20 ml with 10 syringes, 60 ml with 6 syringes140 ml10 ml   
Syringe Size Minimum0.5 µl0.5 µl0.5 µl0.5 µl0.5 µl with 10 syringes, 30 ml with 6 syringes60 ml0.5 µl   
USB ConnectorsType BType BType BType B      
Voltage Range100-240 VAC, 50/60 Hz100-240 VAC, 50/60 Hz100-240 VAC, 50/60 Hz100-240 VAC, 50/60 Hz      

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 73 results for Standard Infuse/Withdraw PHD Ultra Syringe Pumps   Page 1  2  3  4  5  6  7  8 

Score

Document

Description

100% Login to view PP06 Molecular Clocks.pdf
[108 KB]
PHD 22/2000 Syringe Pump used in finding Molecular Clocks
61% Login to view PP116 Analysis of Biomolecular Interactions Using a Miniaturized Surface Plasmon Resonance Sensor.pdf
[93 KB]
PHD 2000 Programmable Syringe Pump used in Analysis of Biomolecular Interactions Using a Miniaturized Surface Plasmon Resonance Sensor
55% Login to view PP96 Intrarenal Dopamine Production and Distribution in the Rat.pdf
[399 KB]
Calibrated Syringe Pump use in finding Anticonvulsant Properties of Ganazolone
52% Login to view PP16 Developing the Atomic Force Microscope for Studies of Living Cells.pdf
[325 KB]
Infusion/Withdrawal Pump use in Developing the atomic force miscoscope for studies of living cells
41% Login to view PP45 Precision Alignment Packaging for Microsystems with Multiple Fluid Connections.pdf
[301 KB]
Union of capillary high-performance liquid chromatography
41% Login to view PP103 Polynuclear Complexes of Copper I and the 2-3-5-Pyrazolyl-6-methylpyridine Ligand.pdf
[253 KB]
Defining Extracellular Integrin Chain Sites That Affect Cell Adhesion and Adhesion Strengthening without Altering Soluble Ligand Binding
39% Login to view PP100 Nonstriatal Dopamine D1 Receptors Regulate Striatal Acetylcholine Release In Vivo.pdf
[215 KB]
Double Syringe Pump use in finding Effects of hyperglycemia
39% Login to view PP99 Microcirculation in Intestinal Villi.pdf
[211 KB]
Syringe Pump use in finding Microcirculation in Intestinal Villi
36% Login to view PP109 Measurement of Intravascular Na+ During Increased CBF Using 23Na NMR with a Shift Reagant.pdf
[135 KB]
Infusion Pump use in finding Measurement of intravascular Na+ during increased CBF using 23Na NMR with a shift reagent
34% Login to view PP81 A Protocol For High-Throughput Drug Mixture Quantitation.pdf
[306 KB]
Microdrive Pump use in Coincident Activation of NMDA and Dopamine D1 Receptors within the Nucleus Accumbens Core Is Required for Appetitive Instrumental Learning
   

Back to Top



Manuals Back to Top

Displaying 1 to 2 of 2 results for Standard Infuse/Withdraw PHD Ultra Syringe Pumps  

Score

Document

Description

100% Login to view 703005 PHD ULTRA Manual.pdf
[2.4 MB]
PHD Ultra Syringe Pumps Manual - Standard/Remote/Programmable
65% Login to view 703005 PHD ULTRA Quickstart.pdf
[173 KB]
PHD Ultra Syringe Pumps Quickstart Guide - Standard/Remote/Programmable
   

Back to Top

Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews