Welcome to Harvard Apparatus! — Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources
Shopping Cart Shopping
   Cart
                     My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
Harvard Apparatus

GoDaddy
 

Home OneDrop Microporator MP-100 System


Larger Views

 

OneDrop Microporator MP-100 System
MicroPoration is a novel non viral method used to transfect difficult cells lines including primary cells. MicroPoration is a unique electroporation technology which uses a specially designed pipette TIP as the electroporation chamber. Typical electroporation is dependent on cuvette style chambers which are used routinely for electroporation. These pipette tips have been developed to produce a uniform electrical field and minimal heat generation within the chamber which result in higher transfection efficiencies and cell viabilities. Imagine your pipette tip is functionally equal to the electroporation cuvette! With the use of these tips smaller sample volumes of 10µl and 100µl can be transfected efficiently. With the fully programmable pulse generator you can simply pipette up your sample, place it in the pipette station, pulse, and then plate your cells. Fast and easy!
Search for Product in current catalog
Item Listing Full Description Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
450600 OneDrop Microporator MP-100 System Yes -- View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Pipette sample, Pulse and Plate, Transfect Directly In Pipette Tip
• High Efficiency and Cell Viability of Hard to Transfect Cells
• 10µl -100µl Samples Now Possible Single Technology for All Cells
• Optimized Protocols and User Control

The OneDrop MicroPorator System is a hand-held pipette-type electroporation device which utilizes powerful MicroPoration technology. It consists of a high performance pulse generator, safety chamber and MicroPorator pipette. Pre-sterilized microporation tips, manufactured by state-of-the-art micromachining factories, are supplied as disposables. The high performance pulse generator has a graphical user interface for easy setting and operation. Setting electrical parameters, number of pulses and pulse duration are graphically visualized with a large LCD display. Pre-optimized electric parameters are provided and updated through the technical support group.


Journal Articles Back to Top

Displaying 1 to 10 of 20 results for OneDrop Microporator MP-100 System   Page 1  2 

Score

Document

Description

100% Login to view Interleukin-12-mediated induction of systemic immunity.pdf
[213 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery and recruitment of activated T cells into the brain produce limited antitumor effects compared with interleukin-2
50% Login to view PP41 y2-Melanocyte-Stimulating Hormone Suppression of Systemic Inflammatory Responses to Endotoxin.pdf
[495 KB]
Melanocyte-stimulating hormone suppression of systemic inflammatory responses
27% Login to view PP86.pdf
[180 KB]
Dexenfluramine-Induced Systemic Vasoconstriction
23% Login to view PI12 mri inject.pdf
[201 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery
20% Login to view PP69 PHD 2000 Syringe Pump.pdf
[598 KB]
Passive mixing in a three-dimensional serpentine microchannel - Microelectromechanical Systems, Journal of
20% Login to view PP41Infusion Pump.pdf
[496 KB]
Melanocyte-stimulating hormone suppression of systemic inflammatory responses
20% Login to view Permeation and Activation of the M2 Ion Channel.PDF
[248 KB]
Permeation and Activation of the M2 Ion Channel of Influenza A Virus with use of Fast Step Perfusion System
19% Login to view TD0160 1.PDF
[348 KB]
Isotomic Transducer use in Stabilization of Temporally Summated Muscle Contractions in the Lobster (Panulirus) Pyloric System
19% Login to view WR19FA 1.PDF
[220 KB]
Permeation and Activation of the M2 Ion Channel of Influenza A Virus with use of Fast Step Perfusion System
17% Login to view PP33PR 1.PDF
[393 KB]
Micro/nano spacecraft thermal control using a MEMS-based pumped liquid cooling system with use of Programmable syringe pump
   

Back to Top



Manuals Back to Top

Displaying 1 to 4 of 4 results for OneDrop Microporator MP-100 System  

Score

Document

Description

100% Login to view metric system trivia.pdf
[146 KB]
Microsoft Word - Lesson1.doc
86% Login to view Perfusion Tissue Systems Guide.pdf
[105 KB]
New BS4_K_Isolated Organ.qxd
82% Login to view 650073 76 Brain Slice Chmbr Manual.pdf
[706 KB]
Brain Slice Chamber System User's Manual
70% Login to view 650073-0076 Manual.pdf
[285 KB]
Brain Slice Chamber System Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews