Welcome to Harvard Apparatus! — Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources
Shopping Cart Shopping
   Cart
                     My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
Harvard Apparatus

GoDaddy
 

Home Basic Stimulator
 


Larger Views

Basic Stimulator
The 6000 Series of stimulators are ideal units for conducting teaching and research experiments. The range, which consists of the 6002 Basic Stimulator, 6012 Dual Pulse Stimulator and the 6020 Dual Impedance Stimulator, have been designed specifically to allow complete compatibility between all 6000 series stimulators. This allows two or more systems to be connected together to make a sophisticated multi channel system.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
506002 Basic Stimulator, Single Pulse, Single Channel -- 10 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Single Pulse, Single Channel
• 50 Volt Pulse Amplitude
• 6 Pulse Widths

The 6000 Series of stimulators are ideal units for conducting teaching and research experiments. The range, which consists of the 6002 Basic Stimulator, 6012 Dual Pulse Stimulator and the 6020 Dual Impedance Stimulator, have been designed specifically to allow complete compatibility between all 6000 series stimulators. This allows two or more systems to be connected together to make a sophisticated multi channel system.
All systems feature variable pulse frequency, 3 operating modes, variable pulse width, variable pulse amplitude, an output on or off selector, pulse indicator, gate in and gate out terminals. The 6012 and 6020 Stimulators also feature a sync output terminal. The 6020 stimulator featurers a delay circuit that allows the output pulse to be delayed in relation to the sync output for oscilloscope timebase to be pre-triggering.
In continuous mode, systems generate a continuous stream of pulses, at the selected frequency, amplitude and pulse width.
In single shot mode, a single pulse is generated at the selected amplitude and pulse width, whenever the single shot key is activated or when the gate in condition is met.
In gate in mode, whenever the gate in condition is met or the single shot key is activated, pulses are produced at the selected frequency, amplitude and pulse width, for as long as the condition remains met.
The 6002 stimulator features a highly stable pulse generator that is continuously adjustable between 0.1Hz to 100Hz, with a variable pulse width that can be set to one of six positions and a maximum output amplitude of
50 Volts.


Specifications Back to Top

Specifications506002
Connections2 x insulated 4 mm sockets (Output)
2 x BNC Socket (Gate Connections)
Frequency Range0.1 to 100 Hz in 3 ranges
Gate InShort Circuit or 12 Volt (Max) Logic Pulse (triggers on falling edge)
Model6002
Output Amplitude0 to 0.5 Volts, 0 to 5 Volts or 0 to 50 Volts
Power110-115 Volts 60 Hz or 220-230 Volts 50 Hz
Pulse Width Range0.1 to 5 mS in six preset steps
Rise and Fall Time> 5 µsec

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 15 results for Basic Stimulator   Page 1  2 

Score

Document

Description

100% Login to view HS10TY IKs block fails to lengthen QTc and APD in rabbit.pdf
[207 KB]
Pharmacological block of the slow component of the outward delayed rectifier fails to lengthen rabbit ventricular muscle and action potential duration
63% Login to view NO01 compare.pdf
[97 KB]
Evaluation of basic performance and applicability of a newly developed in vivo oxide sensor
60% Login to view PP41 y2-Melanocyte-Stimulating Hormone Suppression of Systemic Inflammatory Responses to Endotoxin.pdf
[495 KB]
Melanocyte-stimulating hormone suppression of systemic inflammatory responses
55% Login to view PP61 Temporal Gradients in Shear, but Not Spatial Gradients, Stimulate Endothelial Cell Proliferation.pdf
[514 KB]
Temporal Gradients in Shear, but Not Spatial Gradients, Stimulate Endothelial Cell Proliferation
45% Login to view PP02 Intake of High-Fat Food is Selectively Enhanced by Mu Opioid Receptor Stimulation Within the Nucleus Accumbens.pdf
[215 KB]
Microdrive Pump use in finding Intake of High-Fat Food is Selectively Enhanced by Mu Opioid Receptor Stimulation within the Nucleus Accumbens
44% Login to view HS12P2 Effects of GYK!-16638 in rabbits.pdf
[236 KB]
PII: S0014-2999(00)00591-4
37% Login to view PP61.pdf
[506 KB]
Temporal Gradients in Shear, but Not Spatial Gradients, Stimulate Endothelial Cell Proliferation
33% Login to view PP41Infusion Pump.pdf
[496 KB]
Melanocyte-stimulating hormone suppression of systemic inflammatory responses
31% Login to view VT16 2003683.pdf
[249 KB]
Animal Ventilator finding Hydrogen Peroxide in the Lung Parenchyma Stimulates Vagally Mediated Phrenic Activity
31% Login to view HS11 Type 211 Stimulator.pdf
[94 KB]
Stimulator use in finding native tetanus and pertussis toxins effect on electrical and chemical seizures in mice
   

Back to Top



Manuals Back to Top

Displaying 1 to 1 of 1 result for Basic Stimulator  

Score

Document

Description

100% Login to view PicoInjector PLI100.pdf
[949 KB]
Model PLI-100 Pico Injector Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews