Welcome to Harvard Apparatus! — Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources
Shopping Cart Shopping
   Cart
                     My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
Harvard Apparatus

GoDaddy
 

Home Standard Infusion Only PHD 22/2000 Syringe Pumps


Larger Views

 

Standard Infusion Only PHD 22/2000 Syringe Pumps
The Harvard PHD 22/2000 Advance Syringe Pump family is the most versatile of the pump lines. This pump is available for infusion only or infuse/withdraw models. This is the only pump that is available in a Push/Pull configuration. All pumps have RS-232 communications capabilities, but there are also PHD 22/2000 pumps that are programmable directly from the keypad. In addition, a multitude of syringe racks are available to hold 2, 4 or up to 10 syringes. A microliter syringe rack is also available for microliter applications. Remote versions are also available where the control box and pumping mechanism are separated by a 9.1 meter (30 foot) cable.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
702000 PHD 22/2000 Syringe Pump Infusion Only 2-Syringe Rack Standard Pressure Yes -- View Pricing
Login to Shop
712000 PHD 22/2000 Syringe Pump Infusion Only 2-Syringe Rack High Pressure -- 5 days View Pricing
Login to Shop
702004 PHD 22/2000 Syringe Pump Infusion Only 4 x 140 Multi-Syringe Rack Standard Pressure -- 5 days View Pricing
Login to Shop
712004 PHD 22/2000 Syringe Pump Infusion Only 4 x 140 Multi-Syringe Rack High Pressure -- 5 days View Pricing
Login to Shop
702005 PHD 22/2000 Syringe Pump Infusion Only Microliter 4-Syringe Rack Standard Pressure -- 5 days View Pricing
Login to Shop
712005 PHD 22/2000 Syringe Pump Infusion Only Microliter 4-Syringe Rack High Pressure -- 5 days View Pricing
Login to Shop
702003 PHD 22/2000 Syringe Pump Infusion Only 6/10 Multi-Syringe Rack Standard Pressure -- 5 days View Pricing
Login to Shop
712003 PHD 22/2000 Syringe Pump Infusion Only 6/10 Multi-Syringe Rack High Pressure -- 5 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• High accuracy and precision
• Low flow rate
• Ultimate flexibility and versatility
• 2 year warranty

Forty years ago Harvard Apparatus perfected the lead screw principle and created the first syringe pump. Since that time, tens of thousands of Harvard pumps have earned a reputation as the most reliable research partners in every major laboratory in the World. The PHD 22/2000 syringe pump series gives you the lowest flow rates ever, the highest accuracy, the smoothest flow, advanced programmability from the keypad and yet, is very easy to use.

Highest Accuracy and Precision
A welded steel chassis, machined Delrin™ components, upgraded guide rods, and advanced electronics give accuracy within 0.35% and reproducibility within 0.05%.

Lowest Flow Rates
A new micro stepping motor and control software give the lowest flow rates ever, down to 0.0001 µl/hour. It is also incredibly quiet so it won’t disturb your experimental subjects.

Versatility
There is a PHD 22/2000 syringe pump to meet every need, whether it be simple infusion, infusion and withdrawal, or programming capabilities.

1. Infuse Only:
This pump is suitable for applications that require high accuracy and low rates but, do not need to withdraw fluid and do not need programmability. Should you need withdrawal or program capabilities later on, the infusion only pump can be upgraded

2. Infuse/Withdraw:
The Harvard PHD 22/2000 infuse/withdraw has identical performance to the infusion only model (above) but
can also withdraw (refill).

3. Programmable:
The Harvard PHD 22/2000 Programmable pump has the most advanced programming functions and yet is very easy to use. The pump can store up to four programs of 10 sequences each. Programs are stored in non-volatile memory. No other pump can give you this level of control and flexibility. The programmable pumps may also be programmed using Symphony, Harvard’s Windows™ pump manager software.

Easy to Use
A bright, easy to read, two-line fluorescent display can be easily read from across the lab. A target volume key makes it easy to dispense a set volume. An ergonomic ‘Autolock’ release mechanism is easy for even small hands to operate and can never be left unlocked. The numerical keys utilize the familiar ‘telephone’ layout.

Upgrade
We offer pumps that can be upgraded. If you buy an infuse/withdraw pump and later decide you want programmability you can upgrade it. You pay a lot less than buying a whole new pump.

Program Description
The programming functions of this pump provide powerful capabilities for advanced experiments. While in program mode this pump can perform the following tasks at a predetermined time or when prompted by a signal from an external device:
- start or stop pumping
- change pumping direction (infuse-withdraw)
- change flow rates
- pump a precise volume and stop
- pause operation
- ramp up or down flow rates

In program mode the above tasks can be linked together into powerful programs to simplify your automation projects. Introducing the three newest members to join the PHD 22/2000 family:

High Pressure Syringe Pumps
Every version of the PHD 22/2000 Pump is now available with a stronger motor that can provide more force. These pumps are ideal when working with viscous fluid or when driving multiple syringes. The standard force PHD 22/2000 series syringe pump delivers an average nominal force of 50 lbs. while the high power version delivers 66 lbs. If you require even greater force see the PHD 22/2000 Hpsi or the Pump 4400 Hpsi.

Remotely Controlled Syringe Pump
Use the Hpsi remote pump in hazardous environments where the researcher is safer when distanced from the material being pumped. This pump has a 30 foot cable that allows the pumping mechanism to be located remotely from the control box. Every version of the PHD syringe pump is available in a remote model.

Push/Pull Syringe Pump
The third new member to the PHD 22/2000 family is the Push/Pull PHD 22/2000. This pump can simultaneously infuse and withdraw the exact amount. Use this when you do not want the volume infused to alter pressure. With the addition of a 61-0270 Tubing Segment or a valve box, it can also provide continuous infusion. It is available in both infuse/withdraw and programmable models. The right side syringe holder is the standard 2-syringe rack found on all PHD 22/2000 syringe pumps. This standard holder will accept all the PHD 22/2000 multi-syringe racks (right side only).


Specifications Back to Top

Specifications702000712000702004712004702005712005702003712003
# of Syringes2244446/106/10
Accuracy0.35 %0.35 %0.35 %0.35 %0.35 %0.35 %0.35 %0.35 %
Average Linear Force50 lbs66 lbs50 lbs66 lbs50 lbs66 lbs50 lbs66 lbs
CommunicationsRS-232, TTLRS-232, TTLRS-232, TTLRS-232, TTLRS-232, TTLRS-232, TTLRS-232, TTLRS-232, TTL
Communications Level22222222
Depth English11 in11 in11 in11 in11 in11 in11 in11 in
Depth Metric27.9 cm27.9 cm27.9 cm27.9 cm27.9 cm27.9 cm27.9 cm27.9 cm
DisplayFluorescent, 2-line, 40 characterFluorescent, 2-line, 40 characterFluorescent, 2-line, 40 characterFluorescent, 2-line, 40 characterFluorescent, 2-line, 40 characterFluorescent, 2-line, 40 characterFluorescent, 2-line, 40 characterFluorescent, 2-line, 40 character
Flow Rate Maximum220.82 ml/min220.82 ml/min220.82 ml/min220.82 ml/min31.486 ml/min31.486 ml/min106.76 ml/min106.76 ml/min
Flow Rate Minimum0.0001 µl/hr0.0001 µl/hr0.1019 µl/min0.1019 µl/min0.0001 µl/hr0.0001 µl/hr0.0001 µl/hr0.0001 µl/hr
Height English6.3 in6.3 in6.3 in6.3 in6.3 in6.3 in6.3 in6.3 in
Height Metric15.9 cm15.9 cm15.9 cm15.9 cm15.9 cm15.9 cm15.9 cm15.9 cm
Input Power0.5 A, 65 W0.5 A, 65 W0.5 A, 65 W0.5 A, 65 W0.5 A, 65 W0.5 A, 65 W0.5 A, 65 W0.5 A, 65 W
Motor1/2 to 1/32 microstepping, microprocessor controlled, 1.8° step angle motor1/2 to 1/32 microstepping, microprocessor controlled, 1.8° step angle motor1/2 to 1/32 microstepping, microprocessor controlled, 1.8° step angle motor1/2 to 1/32 microstepping, microprocessor controlled, 1.8° step angle motor1/2 to 1/32 microstepping, microprocessor controlled, 1.8° step angle motor1/2 to 1/32 microstepping, microprocessor controlled, 1.8° step angle motor1/2 to 1/32 microstepping, microprocessor controlled, 1.8° step angle motor1/2 to 1/32 microstepping, microprocessor controlled, 1.8° step angle motor
Motor Stepper 1 Revolution of Lead Screw800 at 1/2 stepping to 12,800 at 1/32 stepping800 at 1/2 stepping to 12,800 at 1/32 stepping800 at 1/2 stepping to 12,800 at 1/32 stepping800 at 1/2 stepping to 12,800 at 1/32 stepping800 at 1/2 stepping to 12,800 at 1/32 stepping800 at 1/2 stepping to 12,800 at 1/32 stepping800 at 1/2 stepping to 12,800 at 1/32 stepping800 at 1/2 stepping to 12,800 at 1/32 stepping
Net Weight English10 lb10 lb10 lb10 lb10 lb10 lb10 lb10 lb
Net Weight Metric4.5 kg4.5 kg4.5 kg4.5 kg4.5 kg4.5 kg4.5 kg4.5 kg
Non Volatile MemoryStorage of all settingsStorage of all settingsStorage of all settingsStorage of all settingsStorage of all settingsStorage of all settingsStorage of all settingsStorage of all settings
PressureStandardMediumStandardMediumStandardMediumStandardMedium
Pump ConfigurationStandardStandardStandardStandardStandardStandardStandardStandard
Pump FunctionInfusion OnlyInfusion OnlyInfusion OnlyInfusion OnlyInfusion OnlyInfusion OnlyInfusion OnlyInfusion Only
Pusher Travel Rate Maximum190.676 mm/min190.676 mm/min190.676 mm/min190.676 mm/min190.676 mm/min190.676 mm/min190.676 mm/min190.676 mm/min
Pusher Travel Rate Minimum0.18 µm/min0.18 µm/min0.18 µm/min0.18 µm/min0.18 µm/min0.18 µm/min0.18 µm/min0.18 µm/min
RS-232RJ11-4 ConnectorRJ11-4 ConnectorRJ11-4 ConnectorRJ11-4 ConnectorRJ11-4 ConnectorRJ11-4 ConnectorRJ11-4 ConnectorRJ11-4 Connector
Reproducibility0.05 %0.05 %0.05 %0.05 %0.05 %0.05 %0.05 %0.05 %
Step Rate Maximum416.7 µsec/step416.7 µsec/step416.7 µsec/step416.7 µsec/step416.7 µsec/step416.7 µsec/step416.7 µsec/step416.7 µsec/step
Step Rate Minimum27.3 sec/step27.3 sec/step27.3 sec/step27.3 sec/step27.3 sec/step27.3 sec/step27.3 sec/step27.3 sec/step
Step Resolution0.082 µm/step0.082 µm/step0.082 µm/step0.082 µm/step0.082 µm/step0.082 µm/step0.082 µm/step0.082 µm/step
Syringe Rack TypeStandard RackStandard Rack4 x 140 ml Syringe Rack4 x 140 ml Syringe RackMicroliter Syringe RackMicroliter Syringe Rack6/10 Multi-Syringe Rack6/10 Multi-Syringe Rack
Syringe Size Maximum140 ml140 ml140 ml140 ml10 ml10 ml60 ml60 ml
Syringe Size Minimum0.5 µl0.5 µl100 ml100 ml0.5 µl0.5 µl0.5 µl0.5 µl
TTL9-pin connector D-sub.9-pin connector D-sub.9-pin connector D-sub.9-pin connector D-sub.9-pin connector D-sub.9-pin connector D-sub.9-pin connector D-sub.9-pin connector D-sub.
TypeMicroprocessor multiple syringe, infusion only or infuse/withdraw, some models programmable from keypadMicroprocessor multiple syringe, infusion only or infuse/withdraw, some models programmable from keypadMicroprocessor multiple syringe, infusion only or infuse/withdraw, some models programmable from keypadMicroprocessor multiple syringe, infusion only or infuse/withdraw, some models programmable from keypadMicroprocessor multiple syringe, infusion only or infuse/withdraw, some models programmable from keypadMicroprocessor multiple syringe, infusion only or infuse/withdraw, some models programmable from keypadMicroprocessor multiple syringe, infusion only or infuse/withdraw, some models programmable from keypadMicroprocessor multiple syringe, infusion only or infuse/withdraw, some models programmable from keypad
Voltage RangeSelectable, 95 to 130 VAC, 60 Hz or 220 to 260 VAC, 50 HzSelectable, 95 to 130 VAC, 60 Hz or 220 to 260 VAC, 50 HzSelectable, 95 to 130 VAC, 60 Hz or 220 to 260 VAC, 50 HzSelectable, 95 to 130 VAC, 60 Hz or 220 to 260 VAC, 50 HzSelectable, 95 to 130 VAC, 60 Hz or 220 to 260 VAC, 50 HzSelectable, 95 to 130 VAC, 60 Hz or 220 to 260 VAC, 50 HzSelectable, 95 to 130 VAC, 60 Hz or 220 to 260 VAC, 50 HzSelectable, 95 to 130 VAC, 60 Hz or 220 to 260 VAC, 50 Hz
Width English9 in9 in9 in9 in9 in9 in9 in9 in
Width Metric22.8 cm22.8 cm22.8 cm22.8 cm22.8 cm22.8 cm22.8 cm22.8 cm

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 68 results for Standard Infusion Only PHD 22/2000 Syringe Pumps   Page 1  2  3  4  5  6  7 

Score

Document

Description

100% Login to view PP06 Molecular Clocks.pdf
[108 KB]
PHD 22/2000 Syringe Pump used in finding Molecular Clocks
48% Login to view PP120 Effect of Endotoxin on P-Glycoprotein-Mediated Biliary and Renal Excretion of Rhodamine-123 in Rats.pdf
[1.1 MB]
PHD 2000 Infusion Pump use in finding Effect of Endotoxin on P-Glycoprotein-Mediated Biliary and Renal Excretion of Rhodamine-123 in Rats
44% Login to view PP40 Impairment in a Discrimination Reversal Task After D1 Receptor Blockade in the Pigeon Prefrontal Cortex.pdf
[977 KB]
Microdrive Infusion Pump use in finding Impairment in a Discrimination Reversal Task After D1 Receptor Blockade in the Pigeon "Prefrontal Cortex"
35% Login to view PP109 Measurement of Intravascular Na+ During Increased CBF Using 23Na NMR with a Shift Reagant.pdf
[135 KB]
Infusion Pump use in finding Measurement of intravascular Na+ during increased CBF using 23Na NMR with a shift reagent
34% Login to view PP59 Characterization of N-Glycans from Arabidopsis.pdf
[264 KB]
Syringe Pump use in Characterization of N-Glycans from Arabidopsis Application to a Fucose-Deficient Mutant
34% Login to view PP107 Predictability Modulates Human Brain Response to Reward.pdf
[300 KB]
Dual Syringe Pump use in finding Predictability Modulates Human Brain Response to Reward
34% Login to view PP108 Effects of Chemotherapy.pdf
[122 KB]
Infusion Pump use in finding Effects of Chemotherapy by 1,3-Bis(2-chloroethyl)-1-nitrosourea
34% Login to view PP49 Drug-Protein Binding and Blood-Brain Barrier Permeability.pdf
[123 KB]
Infusion Pump use in finding Drug-Protein Binding and Blood Brain Barrier Permeability
33% Login to view PP67 Muscimol Inactivation of the Dorsal Hippocampus Impairs Contextual Retrieval of Fear Memory.pdf
[296 KB]
Infusion Pump use in finding Muscimol Inactivation of the Dorsal Hippocampus Impairs Contextual Retrieval of Fear Memory
33% Login to view PP66 Characterization of a Novel Sepia officinalis Neuropeptide Using MALDI-TOF MS and Post-Source Decay Analysis.pdf
[208 KB]
Characterization of a novel Sepia officinalis neuropeptide with use of a Syringe Pump
   

Back to Top



Manuals Back to Top

Displaying 1 to 2 of 2 results for Standard Infusion Only PHD 22/2000 Syringe Pumps  

Score

Document

Description

100% Login to view 703005 PHD ULTRA Manual.pdf
[2.4 MB]
PHD Ultra Syringe Pumps Manual - Standard/Remote/Programmable
62% Login to view 703005 PHD ULTRA Quickstart.pdf
[173 KB]
PHD Ultra Syringe Pumps Quickstart Guide - Standard/Remote/Programmable
   

Back to Top




  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews