Home Centrifugal Pump


Larger Views

 

Centrifugal Pump

The centrifugal pump is specifically designed for pumping blood and/or erythrocyte suspension solutions in the physiological or pharmacological laboratory. It consists of the pump drive BVP-ZX and a centrifugal pump head which can be replaced without tools. Pump heads are hermetically sealed. The coupling to the motor of the pump drive is carried out via magnetic force; there is no axle.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
732470 BVP-ZX Centrifugal Pump, 230 VAC -- 10 days View Pricing
Login to Shop
732963 BVP-ZX Centrifugal Pump, 115 VAC -- 10 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Low hemolysis
• Flow rates up to 16 L/min
• No or only low pulsation
• Smooth run, producing only low noise
• Pump heads interchangeable without tool
• Speed setting by a digital switch in 0.1% steps
• “Max Speed” button for quick fill or ventilate
• Robust construction for long life time
• Analoge interface for remote control

The centrifugal pump is specifically designed for pumping blood and/or erythrocyte suspension solutions in the physiological or pharmacological laboratory. It consists of the pump drive BVP-ZX and a centrifugal pump head which can be replaced without tools. Pump heads are hermetically sealed. The coupling to the motor of the pump drive is carried out via magnetic force; there is no axle.
The pump speed is set using a 3-digit potentiometer switch (000 to 999) or via an analog interface.
The drive is very robust and suitable for continuous speed selection operation.
The pump drive and pump heads must be purchased separately. The pump heads are interchangeable and do not require tools to change.


Specifications Back to Top

Specifications732470732963
Analog InterfaceSpeed Controls 0-5 V or 0-10 V or 0-20 mA or 4-20 mA, start/stop (TTL contacts)Speed Controls 0-5 V or 0-10 V or 0-20 mA or 4-20 mA, start/stop (TTL contacts)
Dimensions (H x W x D) English10.2 x 6.1 x 10.2 in10.2 x 6.1 x 10.2 in
Dimensions (H x W x D) Metric260 x 155 x 260 mm260 x 155 x 260 mm
Mains Connection20 (50/60 Hz) 115 V (50/60 Hz)20 (50/60 Hz) 115 V (50/60 Hz)
ModelBVP-ZXBVP-ZX
Operating Conditions0 - 40 C (normal environment conditions)0 - 40 C (normal environment conditions)
Power Consumption120 W maximum120 W maximum
Protection RatingIP30IP30
Speed3 to 3000 rpm, adjustable in 0.1% steps3 to 3000 rpm, adjustable in 0.1% steps
Weight (without pump head) (kg)7 kg7 kg
Weight (without pump head) (lbs)15.4 lbs15.4 lbs

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 92 results for Centrifugal Pump   Page 1  2  3  4  5  6  7  8  9  10 

Score

Document

Description

100% Login to view PP114 pump microchannel.pdf
[74 KB]
Syringe Infusion Pump use in finding Microchannel Devices for Efficient Contacting of Liquids in Solvent Extraction
100% Login to view PP04 pump ms.pdf
[53 KB]
Analysis of Jojoba Oil with syringe pump 'apparatus 22'
89% Login to view PP96 22 pump eq.pdf
[944 KB]
Syringe Pump use in finding Intrarenal Dopamine Production and Distrobution in the Rat
89% Login to view PP08 Mechanical Pump 901A.pdf
[188 KB]
Mechanical Pump use in finding NO supports right ventricular flow dominance
88% Login to view PP57 Respiratory Pump 57.pdf
[209 KB]
Respirator pump use in finding Quantification of Cerebral Perfusion With "Real Time" Contrast-Enhanced Ultrasound
85% Login to view PP13 Pump 22 Syringe.pdf
[646 KB]
Syringe Pump use in finding A set-point model with oscillatory behavior predicts the time course of 8-OH-DPAT-induced hypothermia
85% Login to view PP12 Pump 11 Syringe.pdf
[179 KB]
Syringe Pump use in Studies of potential-dependent metallothionein adsorptions using a low-volume electrochemical quartz crystal microbalance flow cell
76% Login to view PP50 Blood Pump Model 1421.pdf
[141 KB]
Analysis of Slipstream Flow in a Wide-necked Basilar Artery Aneurysm with use of Blood Pump
69% Login to view VT24 Pump Ventilator.pdf
[90 KB]
Intramucosal-arterial Pco2 gap fails to reflect intestinal dysoxia in hypoxic hypoxia
37% Login to view PP06 Molecular Clocks.pdf
[108 KB]
PHD 22/2000 Syringe Pump used in finding Molecular Clocks
   

Back to Top



Manuals Back to Top

Displaying 1 to 10 of 13 results for Centrifugal Pump   Page 1  2 

Score

Document

Description

100% Login to view 551762 Peristaltic Pumps Manual.pdf
[202 KB]
Peristaltic Pump 1200 Series User's Manual
99% Login to view 703005 PHD ULTRA Manual.pdf
[2.4 MB]
PHD Ultra Syringe Pumps Manual - Standard/Remote/Programmable
97% Login to view 702202 OEM Pump Manual.pdf
[602 KB]
High Force Modulat Pumping Component User's Manual
97% Login to view 551838 Blood Pump Manual.pdf
[432 KB]
Series 1400 Pulsatile Blood Pumps User's Manual
97% Login to view 702203 OEM Pump Manual.pdf
[487 KB]
Milliliter Flow M.P.C Modular Pumping Component User's Manual
88% Login to view 702217 Nanomite Syringe Pump Manual.pdf
[893 KB]
Nanomite Syringe Pump User's Manual
86% Login to view Nanoleader Pump Series NLS110P Pressure Pump Manual.pdf
[2.2 MB]
705000 NLS110P Pump Manual
85% Login to view 702027 Mini Peristaltic Pump Manual.pdf
[279 KB]
Harvard MP II Mini-Peristaltic Pump User's Manual
58% Login to view 12Speed Gear Box Pump Manual.pdf
[888 KB]
12 Speed Gear Box Pump Manual
57% Login to view Pump Selection Guide.pdf
[263 KB]
DC1_A_Pumps.qxd
   

Back to Top

Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews