Welcome to Harvard Apparatus! — Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources
Shopping Cart Shopping
   Cart
                     My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
Harvard Apparatus

GoDaddy
 

Home Dual Manipulator Stereotaxic Instrument for Small Species


Larger Views

 

Dual Manipulator Stereotaxic Instrument for Small Species
Two manipulator arms allow bilateral injections, implants or stimulating and recording.

The Lab Standard’s custom, triple-start lead screws allow the fastest positioning possible consistent with lining up the scales easily for a given position.

The universal joint allows the investigator to angle the probe in either the anterior-posterior or the lateral-medial planes. The improved locking mechanism on the Lab Standard Stereotaxic Instruments will hold any angled position without slippage. Of course, it also provides an absolute lock at the vertical position. The manipulator arm may be swiveled out of the way for convenience in installing the animal or performing a procedure, then returned to the same point reliably with the aid of the locking face block above the swivel joint.

Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
724792 Model 51603 Dual Lab Standard Stereotaxic Frame for Rats with 18° Ear Bars -- 10 days View Pricing
Login to Shop
724793 Model 51653 Dual Lab Standard Stereotaxic Frame for Rats with 45° Ear Bars -- 10 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Available for mice or rats
• Numerals on scales are larger and easier to read
• Laser engraved scale lines provide precise position to 0.1mm
• Absolute lock at 90°
• Available both in single and dual manipulator models

Smooth Movements
The Lab Standard’s custom, triple-start lead screws allow the fastest positioning possible consistent with lining up the scales easily for a given position.

The universal joint allows the investigator to angle the probe in either the anterior-posterior or the lateral-medial planes. The improved locking mechanism on the Lab Standard Stereotaxic Instruments will hold any angled position without slippage. Of course, it also provides an absolute lock at the vertical position. The manipulator arm may be swiveled out of the way for convenience in installing the animal or performing a procedure, then returned to the same point reliably with the aid of the locking face block above the swivel joint.

Easy-to-Read Scales
All scales are oriented to be read most easily from the open end of the “U”. This is the position from which most operators prefer to work. The numerals on the scales are larger and therefore more readable than on competing units. The scale lines are very finely drawn to allow precise alignment with facing scales, and are laser engraved for reliable, consistent quality.

Species
These Stereotaxic Frame Systems are supplied with the necessary components to work with rats. In order to work with other species the appropriate adaptor must be purchased separately. see pages L37 and L38 for species adaptors.

Single and Dual Manipulator Models
The time-proven U-Frame design concept, rugged construction, and adaptability to most species used in the lab make this the best choice for a stereotaxic instrument. The Lab Standard 51600, manufactured by Stoelting, offers several advantages over other U-Frame stereotaxic instruments.

Dual Manipulator Model
The 51603 and 51653 Dual Manipulator Lab Standard are configured with 3-dimensional manipulator arms on both sides. The second manipulator arm is properly reversed as to handedness.

Accessories
Both the 51600 and 51603 come complete with a standard probe holder with corner clamp (51631) and a Rat Adaptor (51621) with nose holder and 18 degree taper ear bars. The 51650 and 51653 include the non-puncture 45 degree ear bars instead of the 18 degree ear bars. They are otherwise identical to the 51600 and 51603.

Optional accessories are available. Probe holders and species adaptors for “U” frame stereotaxic instruments made by other manufacturers are generally compatible with the Lab Standard frame. If you are new to stereotaxic surgery, we would recommend you purchase 72-4240 Stereotaxic Surgery in the Rat.


Specifications Back to Top

Specifications724792724793
AnimalRatRat
Ear Bar Angle18°45°

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 19 results for Dual Manipulator Stereotaxic Instrument for Small Species   Page 1  2 

Score

Document

Description

100% Login to view PP112 pmp2002.pdf
[247 KB]
Syringe Pump use in Production of small molecular weight catalysts
92% Login to view MC02 Species Differences in Pharmacokinetics of a Hepatoprotective Agent.pdf
[168 KB]
Respiration Metabolic Cage use in finding species differences in Pharmacokinetics of a Hepatoprotective agent
91% Login to view VT23 Inhibition Shapes Frequency Response Areas with Small Animal Ventilator.pdf
[673 KB]
Inhibition Shapes Frequency Response Areas with Small Animal Ventilator
84% Login to view VT11 Effects of Concentrated Ambient Particles in rats and Hamsters with Small Animal Respirator.pdf
[874 KB]
Effects of Concentrated Ambient Particles in rats and Hamsters with Small Animal Respirator
65% Login to view PP107 mri pmp5.pdf
[295 KB]
Dual Syringe Pump use in finding Predictability Modulates Human Brain Response to Reward
57% Login to view BTX02 ECM830.pdf
[172 KB]
Requirement of Species-Specific Interactions for the Activation of Human T Cells by Pamidronate
52% Login to view VT12 Small rodent ventilator use in finding chronic measurement of cardiac output in conscious mice.pdf
[184 KB]
Small rodent ventilator use in finding chronic measurement of cardiac output in conscious mice
46% Login to view PP76 Microdrive Pump.pdf
[297 KB]
Microdrive Pump use in Coincident Activation of NMDA and Dopamine D1 Receptors within the Nucleus Accumbens Core Is Required for Appetitive Instrumental Learning
43% Login to view MC02metabolic cage pump.pdf
[166 KB]
Respiration Metabolic Cage use in finding species differences in Pharmacokinetics of a Hepatoprotective agent
43% Login to view lipomat.pdf
[66 KB]
LipoPrep Instrument used in Engineering Porphyrin Encapsulated Vesicles for Metal Removal from Wastewater
   

Back to Top



Manuals Back to Top

Displaying 1 to 1 of 1 result for Dual Manipulator Stereotaxic Instrument for Small Species  

Score

Document

Description

100% Login to view Stereotaxic Instrument Guide.pdf
[36 KB]
BS4_L_Neuroscience.qxd
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews