Welcome to Harvard Apparatus! — Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources
Shopping Cart Shopping
   Cart
                     My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
Harvard Apparatus

GoDaddy
 

Home AES Active Gas Evacuation Systems


Larger Views

 

AES Active Gas Evacuation Systems
The Anesthetic Evacuation System (AES) will safely and actively remove waste gas associated with everyday inhalation anesthesia. It can be mounted on the pole of the CDS-2000, Vaporstick Plus or Vaporstick, see pages F16 to F17. It can also be used as a freestanding unit and simply placed on the benchtop. Two standard 19 mm (0.75 inch) inlets and one exhaust port allows easy hook-up to existing equipment. A 12 foot grounded electrical cord and lightweight tubing, allows for machine maneuverability.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
723064 AES Active Gas Evacuation, 110 VAC 60 Hz -- 10 days View Pricing
Login to Shop
723065 AES Active Gas Evacuation, 220 VAC 50 Hz -- 10 days View Pricing
Login to Shop
723093 AES Tubing 19 mm (0.75 in) ID , 3 m (10 ft) length -- 10 days View Pricing
Login to Shop
723085 AES Male Adapters 19 mm X 19 mm -- 10 days View Pricing
Login to Shop
723070 AES Ceiling Plate Cover -- 10 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Powered unit for safe and effective removal of anesthetic waste gas
• Can be mounted to anesthesia machine pole or used as a free standing unit
• Two inlet ports allow connection to an induction chamber and an anesthesia machine simultaneously

The Anesthetic Evacuation System (AES) will safely and actively remove waste gas associated with everyday inhalation anesthesia. It can be mounted on the pole of the CDS-2000, Vaporstick Plus or Vaporstick. It can also be used as a freestanding unit and simply placed on the benchtop. Two standard 19 mm (0.75 inch) inlets and one exhaust port allows easy hook-up to existing equipment. A 12 foot grounded electrical cord and lightweight tubing, allows for machine maneuverability.

The waste gas from the pop-off valve on most rebreathing anesthesia machines is collected by passive flow to the AES. This allows for safe operation of the anesthesia machine with little or no vacuum exposure. Using a push blower, the AES actively removes the waste gas from the unit. The blower has the capacity of moving 12 cubic feet/minute through up to 150 feet of tubing to an outside vent or fume hood. The on/off switch illuminates a green light when the unit is activated. The ‘on’ light assures the operator that the unit is functioning.

The Anesthetic Evacuation System includes a 3 inch and a 10 foot length of 19 mm ID hose and a 12.5 mm (0.5 inch) PVC Adapter. Additional lengths of tubing may be required and are available as an option along with an adapter to interconnect the 19 mm outlet tubing. An optional outlet line ceiling plate is available when connection to an outside wall is not convenient.


Specifications Back to Top

Specifications723064723065723093723085723070
ID English*na in*na in0.75 in0.75 in*na in
ID Metric*na mm*na mm19 mm19 mm*na mm
Length English*na ft*na ft10 ft*na ft*na ft
Length Metric*na m*na m3 m*na m*na m
Power110 VAC 60 Hz220 VAC 50 Hz   

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 30 results for AES Active Gas Evacuation Systems   Page 1  2  3 

Score

Document

Description

100% Login to view Interleukin-12-mediated induction of systemic immunity.pdf
[213 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery and recruitment of activated T cells into the brain produce limited antitumor effects compared with interleukin-2
90% Login to view Permeation and Activation of the M2 Ion Channel.PDF
[248 KB]
Permeation and Activation of the M2 Ion Channel of Influenza A Virus with use of Fast Step Perfusion System
46% Login to view Platelet-activating factor modulates cardiorespiratory.pdf
[117 KB]
Platelet-activating factor modulates cardiorespiratory responses in the conscious rat
45% Login to view WR19FA 1.PDF
[220 KB]
Permeation and Activation of the M2 Ion Channel of Influenza A Virus with use of Fast Step Perfusion System
44% Login to view 4-Methylhomoibotenic Acid Activates a Novel Metabotropic.pdf
[453 KB]
Oocyte Clamp Amplifier use in finding 4-Methylhomoibotenic Acid Activates a Novel Metabotropic Glutamate Receptor Coupled to Phosphoinostide
44% Login to view Activation of calcium entry in human carcinoma.pdf
[199 KB]
Patch Clamp Amplifier use in Activation of calcium entry in human carcinoma A431 cells
33% Login to view spin col activ char.pdf
[1.3 MB]
Profiling of Human Serum Glycans Associated with Liver Cancer and Cirrhosis by IMS-MS
32% Login to view PI12 mri inject.pdf
[201 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery
32% Login to view PP41 y2-Melanocyte-Stimulating Hormone Suppression of Systemic Inflammatory Responses to Endotoxin.pdf
[495 KB]
Melanocyte-stimulating hormone suppression of systemic inflammatory responses
31% Login to view PP41Infusion Pump.pdf
[496 KB]
Melanocyte-stimulating hormone suppression of systemic inflammatory responses
   

Back to Top



Manuals Back to Top

Displaying 1 to 4 of 4 results for AES Active Gas Evacuation Systems  

Score

Document

Description

100% Login to view metric system trivia.pdf
[146 KB]
Microsoft Word - Lesson1.doc
86% Login to view Perfusion Tissue Systems Guide.pdf
[105 KB]
New BS4_K_Isolated Organ.qxd
82% Login to view 650073 76 Brain Slice Chmbr Manual.pdf
[706 KB]
Brain Slice Chamber System User's Manual
70% Login to view 650073-0076 Manual.pdf
[285 KB]
Brain Slice Chamber System Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews