Home ECM 630 Exponential Decay Wave Electroporation System


Larger Views

 

ECM 630 Exponential Decay Wave Electroporation System
The ECM 630 is an exponential decay wave electroporation generator which allows the researcher full
flexibility in choosing a wide range of time constants. From the 8300 RC time constants in low voltage mode to 126 RC time constants in high voltage mode, the ECM 630 is outstanding in its class, allowing the precise optimization of protocols.

Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
450001 ECM 630 Electroporation System includes ECM 630 Generator (45-0051), 630B Safety Stand (45-0207), Cuvettes 1 mm, 2 mm, 4 mm pkg. of 30 (10 each) and Cuvette Rack 660 (45-0208) (Model 6300) -- 5 days View Pricing
Login to Shop
450051 ECM 630 Generator Only (Model ECM 630) Yes -- View Pricing
Login to Shop
450061 ECM 830 / ECM 630 Combination package
includes ECM 830 Generator, ECM 630 Generator, 2 x Safety Stands, Sample Package of Cuvettes and Cuvette Rack
-- 5 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

Applications:
• Transformation of Bacteria and Yeast
• Transfection of Mammalian Cells
• Transfection of Plant Tissue and Protoplast
• Electroporation of Medaka Oocytes and Insect Cells

POWERFUL
High voltage mode allows for unsurpassed power.

FLEXIBLE
Flexible time constant settings allow for precise optimization of bacterial, yeast, plant and mammalian protocols.

ADAPTABLE
Reproduce protocols from competitive electroporators.

The ECM 630 is an exponential decay wave electroporation generator which allows the researcher full flexibility in choosing a wide range of time constants. From the 8300 RC time constants in low voltage mode to 126 RC time constants in high voltage mode, the ECM 630 is outstanding in its class, allowing the precise optimization of protocols. By setting the resistance parameter to “None”, users can reproduce protocols from competitive electroporators.

In addition, over 200 protocols are available for this instrument. The ECM 630 will perform the widest range of electroporation applications among commercial exponential decay wave electroporators. These features, combined with our 2-year warranty, make the ECM 630 essential for any molecular biology laboratory.

Monitoring Option
The New VIP 3000 allows monitoring and tracking of key electrical parameters used in electroporation. When used with the optional communications module, parameters can be downloaded to a computer or printer for documentation.

Multi-Well Electroporation
The New MOS - Multi-Well Optimization System offers the researcher the advantage of multi-well technology using BTX ECM Generators.


Specifications Back to Top

Specifications450001450051450061
Arc ControlArc Quenching™Arc Quenching™Arc Quenching™
Capacitance HV Mode25 µF and 50 µF25 µF and 50 µF25 µF and 50 µF
Capacitance LV Mode1 µF, 25 µF to 3275 µF1 µF, 25 µF to 3275 µF1 µF, 25 µF to 3275 µF
CertificationsCE MarkCE MarkCE Mark
Charge Time24 sec maximum (without delay)24 sec maximum (without delay)24 sec maximum (without delay)
ControlsSingle rotary knob with push button toggle to set parameters. On/Off Power and Start switchesSingle rotary knob with push button toggle to set parameters. On/Off Power and Start switchesSingle rotary knob with push button toggle to set parameters. On/Off Power and Start switches
DC Voltage Range HV Mode50 to 2500 V / 5 V resolution50 to 2500 V / 5 V resolution50 to 2500 V / 5 V resolution
DC Voltage Range LV Mode10 to 500 V / 1 V resolution10 to 500 V / 1 V resolution10 to 500 V / 1 V resolution
Depth English12.25 in12.25 in12.25 in
Depth Metric31.1 cm31.1 cm31.1 cm
Display4 line x 20 character LCD4 line x 20 character LCD4 line x 20 character LCD
Electroporation ChamberSafety StandSafety StandSafety Stand
Height English5.5 in5.5 in5.5 in
Height Metric14 cm14 cm14 cm
InterfaceDigital User InterfaceDigital User InterfaceDigital User Interface
Internal Resistance HV Mode25 ? to 1575 ? / 25 ? resolution25 ? to 1575 ? / 25 ? resolution25 ? to 1575 ? / 25 ? resolution
Internal Resistance LV Mode25 ? to 1575 ?/25 ? resolution "None" setting to simulate alternative system slacking resistance25 ? to 1575 ?/25 ? resolution "None" setting to simulate alternative system slacking resistance25 ? to 1575 ?/25 ? resolution "None" setting to simulate alternative system slacking resistance
MOS Multi-Well CompatibleYesYesYes
Model6300630 
MonitoringMonitoring and display of V, t, n, intervalMonitoring and display of V, t, n, intervalMonitoring and display of V, t, n, interval
Opererational StatusInternal self test upon start-upInternal self test upon start-upInternal self test upon start-up
Power100 to 240 VAC, 50/60 Hz100 to 240 VAC, 50/60 Hz100 to 240 VAC, 50/60 Hz
ProgrammabilityStorage for 2 parameters (V, t, n, interval)Storage for 2 parameters (V, t, n, interval)Storage for 2 parameters (V, t, n, interval)
Pulse WaveformExponential DecayExponential DecayExponential Decay
Remote OperationNoNoNo
SafetyGenerator is short circuit proofGenerator is short circuit proofGenerator is short circuit proof
Warranty2 Years2 Years2 Years
Weight English10 lbs10 lbs10 lbs
Weight Metric4.5 kg4.5 kg4.5 kg
Width English12.5 in12.5 in12.5 in
Width Metric31.8 cm31.8 cm31.8 cm

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 26 results for ECM 630 Exponential Decay Wave Electroporation System   Page 1  2  3 

Score

Document

Description

100% Login to view Interleukin-12-mediated induction of systemic immunity.pdf
[213 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery and recruitment of activated T cells into the brain produce limited antitumor effects compared with interleukin-2
54% Login to view BTX11 Electroporation.pdf
[182 KB]
Electroporation Transactivation of gp130 in Myeloma Cells
50% Login to view PP41 y2-Melanocyte-Stimulating Hormone Suppression of Systemic Inflammatory Responses to Endotoxin.pdf
[495 KB]
Melanocyte-stimulating hormone suppression of systemic inflammatory responses
35% Login to view BTX07 Electroporator.pdf
[457 KB]
Electroporator and role of Vesicle-Associated Membrane Protein-2
33% Login to view BTX03 Electroporator.pdf
[588 KB]
Electroporator used in Recruitment of MHC Class 1 Molecules
27% Login to view PP86.pdf
[180 KB]
Dexenfluramine-Induced Systemic Vasoconstriction
27% Login to view BTX05 Electroporator.pdf
[166 KB]
Electroporator & CTLA-4 Differentially Regulates Mitogen-Activated Protein Kinases in CD4 T Cells from Receptor/Ligan-Dificient Mice
23% Login to view PI12 mri inject.pdf
[201 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery
23% Login to view PP66 Characterization of a Novel Sepia officinalis Neuropeptide Using MALDI-TOF MS and Post-Source Decay Analysis.pdf
[208 KB]
Characterization of a novel Sepia officinalis neuropeptide with use of a Syringe Pump
20% Login to view PP69 PHD 2000 Syringe Pump.pdf
[598 KB]
Passive mixing in a three-dimensional serpentine microchannel - Microelectromechanical Systems, Journal of
   

Back to Top



Manuals Back to Top

Displaying 1 to 4 of 4 results for ECM 630 Exponential Decay Wave Electroporation System  

Score

Document

Description

100% Login to view metric system trivia.pdf
[146 KB]
Microsoft Word - Lesson1.doc
86% Login to view Perfusion Tissue Systems Guide.pdf
[105 KB]
New BS4_K_Isolated Organ.qxd
82% Login to view 650073 76 Brain Slice Chmbr Manual.pdf
[706 KB]
Brain Slice Chamber System User's Manual
70% Login to view 650073-0076 Manual.pdf
[285 KB]
Brain Slice Chamber System Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews