ECM 830 Square Wave Electroporation System
The ECM 830 is a Square Wave Electroporation System designed for In Vitro and In Vivo electroporation applications. BTX square wave technology offers the researcher the ability to transfect cells efficiently and with higher cell viabilities. The versatility of the ECM 830 applications includes mammalian and plant cell transfections, embryo manipulation, nuclear transfer, and bacterial and yeast transformations.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
450002 ECM 830 Electroporation System includes, ECM 830 Generator (45-0052), 630B Safety Stand (45-0207), Cuvettes 1 mm, 2 mm, 4 mm pkg. of 30 (10 each) and Cuvette Rack 660 (45-0208) (Model 8300) -- 5 days View Pricing
Login to Shop
450052 ECM 830 Generator Only (Model ECM 830) Yes -- View Pricing
Login to Shop
450061 ECM 830 / ECM 630 Combination Package
includes ECM 830 Generator, ECM 630 Generator, 2 x Safety Stands, Sample Package of Cuvettes and Cuvette Rack
-- 5 days View Pricing
Login to Shop
450060 ECM 830 / ECM 399 Combination Package
includes ECM 830 Generator, ECM 399 Generator, Safety Stand, PEP, Sample Package of Cuvettes and Cuvette Rack
-- 5 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

Applications:
• Transfection of Mammalian Cells
• In Vitro, In Vivo, Ex Vivo and In Ovo Experiments
• Nuclear Transfer
• Plant Tissue and Protoplast Transfection
• Transformation of Bacteria and Yeast

CONSISTENT
Square wave technology for increased efficiencies and
viability of mammalian cells.

FLEXIBLE
User control of all parameters for ultimate flexibility
in protocols.

VERSATILE
Unlimited possibilities for electroporation applications with extensive line of BTX specialty electrodes and the new BTX MOS Multi-Well Electroporation Plates.

The ECM 830 is a Square Wave Electroporation System designed for In Vitro and In Vivo electroporation applications. BTX square wave technology offers the researcher the ability to transfect cells efficiently and with higher cell viabilities. The versatility of the ECM 830 applications includes mammalian and plant cell transfections, embryo manipulation, nuclear transfer, and bacterial and yeast transformations. The ECM 830 possesses key features including a wide range of voltages from 5 to 3000 volts, finer voltage discrimination, pulse durations from 10 µsec to 10 sec, user control of pulse intervals, Arc Quenching™, digital display of actual voltage and pulse length delivered. It is a true laboratory work-horse with a 2-year warranty.

The ECM 830 can be used in combination with a host of BTX specialty electrodes and accessories to enhance your molecular and drug delivery in In Vivo and Ex Vivo experiments.

Monitoring Option
The New VIP 3000 System allows monitoring and tracking of key electrical parameters used in electroporation. When used with the optional communications module, parameters can be downloaded to a computer or printer for documentation, see page 6 for more details.

Multi-Well Electroporation
The New MOS - Multi-Well Optimization System offers the researcher the advantage of multi-well technology using BTX ECM Generators.


Specifications Back to Top

Specifications450002450052450061450060
Arc ControlArc Quenching™Arc Quenching™Arc Quenching™Arc Quenching™
Capacitance HV Mode111 µF111 µF111 µF111 µF
Capacitance LV Mode4000 µF4000 µF4000 µF4000 µF
CertificationsCE MarkCE MarkCE MarkCE Mark
Charge Time5 sec maximum (without delay)5 sec maximum (without delay)5 sec maximum (without delay)5 sec maximum (without delay)
ControlsSingle rotary knob with push button toggle to set parameters. On/Off Power and Start switchesSingle rotary knob with push button toggle to set parameters. On/Off Power and Start switchesSingle rotary knob with push button toggle to set parameters. On/Off Power and Start switchesSingle rotary knob with push button toggle to set parameters. On/Off Power and Start switches
DC Pulse Length Range HV Mode10 to 600 µsec / 1 µsec resolution10 to 600 µsec / 1 µsec resolution10 to 600 µsec / 1 µsec resolution10 to 600 µsec / 1 µsec resolution
DC Pulse Length Range LV Mode 110 µsec to 999 µsec / 1 µsec resolution10 µsec to 999 µsec / 1 µsec resolution10 µsec to 999 µsec / 1 µsec resolution10 µsec to 999 µsec / 1 µsec resolution
DC Pulse Length Range LV Mode 21 msec to 999msec / 1 msec resolution1 msec to 999msec / 1 msec resolution1 msec to 999msec / 1 msec resolution1 msec to 999msec / 1 msec resolution
DC Pulse Length Range LV Mode 31 sec to 10 sec / 0.1 sec resolution1 sec to 10 sec / 0.1 sec resolution1 sec to 10 sec / 0.1 sec resolution1 sec to 10 sec / 0.1 sec resolution
DC Voltage Range HV Mode505 to 3000 V / 5 V resolution505 to 3000 V / 5 V resolution505 to 3000 V / 5 V resolution505 to 3000 V / 5 V resolution
DC Voltage Range LV Mode5 to 500 V / 1 V resolution5 to 500 V / 1 V resolution5 to 500 V / 1 V resolution5 to 500 V / 1 V resolution
Depth English12.25 in12.25 in12.25 in12.25 in
Depth Metric31.1 cm31.1 cm31.1 cm31.1 cm
Display4 line x 20 character LCD4 line x 20 character LCD4 line x 20 character LCD4 line x 20 character LCD
Electroporation ChamberSafety Stand or Plate HandlerSafety Stand or Plate HandlerSafety Stand or Plate HandlerSafety Stand or Plate Handler
Height English5.5 in5.5 in5.5 in5.5 in
Height Metric14 cm14 cm14 cm14 cm
InterfaceDigital User InterfaceDigital User InterfaceDigital User InterfaceDigital User Interface
Internal Resistance HV Mode56 ?56 ?56 ?56 ?
Internal Resistance LV Mode56 ?56 ?56 ?56 ?
MOS Multi-Well CompatibleYesYesYesYes
Model8300830  
MonitoringMonitoring and display of V, t, n, intervalMonitoring and display of V, t, n, intervalMonitoring and display of V, t, n, intervalMonitoring and display of V, t, n, interval
Multi-Pulsing1 to 991 to 991 to 991 to 99
Opererational StatusInternal self test upon start-upInternal self test upon start-upInternal self test upon start-upInternal self test upon start-up
Power100 to 240 VAC, 50/60 Hz100 to 240 VAC, 50/60 Hz100 to 240 VAC, 50/60 Hz100 to 240 VAC, 50/60 Hz
ProgrammabilityStorage for 2 parameters (V, t, n, interval)Storage for 2 parameters (V, t, n, interval)Storage for 2 parameters (V, t, n, interval)Storage for 2 parameters (V, t, n, interval)
Pulse Interval100 msec to 10 sec100 msec to 10 sec100 msec to 10 sec100 msec to 10 sec
Pulse WaveformSquare WaveSquare WaveSquare WaveSquare Wave
Remote OperationFoot Switch AvailableFoot Switch AvailableFoot Switch AvailableFoot Switch Available
SafetyGenerator is short circuit proofGenerator is short circuit proofGenerator is short circuit proofGenerator is short circuit proof
Warranty2 Years2 Years2 Years2 Years
Weight English15 lbs15 lbs15 lbs15 lbs
Weight Metric6.8 kg6.8 kg6.8 kg6.8 kg
Width English12.5 in12.5 in12.5 in12.5 in
Width Metric31.8 cm31.8 cm31.8 cm31.8 cm

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 24 results for ECM 830 Square Wave Electroporation System   Page 1  2  3 

Score

Document

Description

100% Login to view Interleukin-12-mediated induction of systemic immunity.pdf
[213 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery and recruitment of activated T cells into the brain produce limited antitumor effects compared with interleukin-2
54% Login to view BTX11 Electroporation.pdf
[182 KB]
Electroporation Transactivation of gp130 in Myeloma Cells
50% Login to view PP41 y2-Melanocyte-Stimulating Hormone Suppression of Systemic Inflammatory Responses to Endotoxin.pdf
[495 KB]
Melanocyte-stimulating hormone suppression of systemic inflammatory responses
35% Login to view BTX07 Electroporator.pdf
[457 KB]
Electroporator and role of Vesicle-Associated Membrane Protein-2
33% Login to view BTX03 Electroporator.pdf
[588 KB]
Electroporator used in Recruitment of MHC Class 1 Molecules
27% Login to view PP86.pdf
[180 KB]
Dexenfluramine-Induced Systemic Vasoconstriction
27% Login to view BTX05 Electroporator.pdf
[166 KB]
Electroporator & CTLA-4 Differentially Regulates Mitogen-Activated Protein Kinases in CD4 T Cells from Receptor/Ligan-Dificient Mice
23% Login to view PI12 mri inject.pdf
[201 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery
20% Login to view PP69 PHD 2000 Syringe Pump.pdf
[598 KB]
Passive mixing in a three-dimensional serpentine microchannel - Microelectromechanical Systems, Journal of
20% Login to view PP41Infusion Pump.pdf
[496 KB]
Melanocyte-stimulating hormone suppression of systemic inflammatory responses
   

Back to Top



Manuals Back to Top

Displaying 1 to 4 of 4 results for ECM 830 Square Wave Electroporation System  

Score

Document

Description

100% Login to view metric system trivia.pdf
[146 KB]
Microsoft Word - Lesson1.doc
86% Login to view Perfusion Tissue Systems Guide.pdf
[105 KB]
New BS4_K_Isolated Organ.qxd
82% Login to view 650073 76 Brain Slice Chmbr Manual.pdf
[706 KB]
Brain Slice Chamber System User's Manual
70% Login to view 650073-0076 Manual.pdf
[285 KB]
Brain Slice Chamber System Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews