Welcome to Harvard Apparatus! — Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources
Shopping Cart Shopping
   Cart
                     My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
Harvard Apparatus

GoDaddy
 

Home VIP 3000 Monitoring Systems


Larger Views

 

VIP 3000 Monitoring Systems
The VIP 3000 Monitoring System provides new capabilities to traditional electroporation methods. It allows users to automatically capture and display electroporation parameters. By adding the optional Communications Module it permits storage and documentation of data for further analysis.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
450059 VIP 3000SC System: Interface Box, VIP 3000 Probe, Digital Oscilloscope, Communications Module and Cables (Model VIP3000SC) -- 5 days View Pricing
Login to Shop
450058 VIP 3000S System: Interface Box, VIP 3000 Probe, Digital Oscilloscope and Cables (Model VIP 3000S) -- 5 days View Pricing
Login to Shop
450057 VIP 3000: Interface Box, VIP 3000 Probe and Cables* (Model VIP 3000) * Requires a digital Oscilloscope for readout of waveforms and electrical parameters. Yes -- View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

Applications:
• Optimize and Troubleshoot Electroporation Settings
• Capture and Print Results for Documentation Purposes
• Track and Download Images to Computer for Analysis

OPTIMIZE
Displays actual electroporation parameters as a waveform and verifies conditions for optimization and troubleshooting.

CONFIRM
Capture electroporation settings and analyze pulse amplitude, field strength, pulse length, AC pulse duration and frequency.

VALIDATE
Communications Module option enables the user to print or store data for routine QC, methods validation and SOP compliance.

The VIP 3000 Monitoring System provides new capabilities to traditional electroporation methods. It allows users to automatically capture and display electroporation parameters. By adding the optional Communications Module it permits storage and documentation of data for further analysis.

The VIP 3000 Monitoring System can monitor all key electroporation parameters including:
• Wave Form
• Peak Amplitude
• Field Strength
• Pulse Lengths
• Pulse Intervals
• AC duration

Capturing this data is possible when using any electroporation generators with external pulse capabilities.

The VIP 3000 System is comprised of 3 components: a Voltage Interface Probe, an Interface Box and a digital Oscilloscope.

The Voltage Interface Probe and Interface Box together comprise the voltage monitor, while the Oscilloscope displays waveform images from the actual electrical pulse. This system offers a solution for evaluating critical electroporation settings.


Specifications Back to Top

Specifications450059450058450057
Cable Length English35 in35 in35 in
Cable Length Metric88.9 cm88.9 cm88.9 cm
Cable TypeBNCBNCBNC
Input Lead Length Metric12 in12 in12 in
Input Voltage Common Mode Range±7000 V (DC+Peak AC) or 2500 Vrms at 1/100 & 1/1000±7000 V (DC+Peak AC) or 2500 Vrms at 1/100 & 1/1000±7000 V (DC+Peak AC) or 2500 Vrms at 1/100 & 1/1000
ModelVIP3000SCVIP 3000SVIP 3000
Output Voltage Max. Amplitude±7 V (into 50 k? load)±7 V (into 50 k? load)±7 V (into 50 k? load)
Output Voltage Offset±5 mV±5 mV±5 mV
Power Requirements4 AA batteries or optional mains adapter4 AA batteries or optional mains adapter4 AA batteries or optional mains adapter
Probe Current15 A, maximum continuous15 A, maximum continuous15 A, maximum continuous
Probe Current (Peak)1000 A for 100 µsec1000 A for 100 µsec1000 A for 100 µsec
Probe Type4 mm Banana Jack4 mm Banana Jack4 mm Banana Jack
Probe Voltage2500 Vrms, 3500 Vpk CAT II2500 Vrms, 3500 Vpk CAT II2500 Vrms, 3500 Vpk CAT II

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 21 results for VIP 3000 Monitoring Systems   Page 1  2  3 

Score

Document

Description

100% Login to view Interleukin-12-mediated induction of systemic immunity.pdf
[213 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery and recruitment of activated T cells into the brain produce limited antitumor effects compared with interleukin-2
50% Login to view PP41 y2-Melanocyte-Stimulating Hormone Suppression of Systemic Inflammatory Responses to Endotoxin.pdf
[495 KB]
Melanocyte-stimulating hormone suppression of systemic inflammatory responses
27% Login to view PP86.pdf
[180 KB]
Dexenfluramine-Induced Systemic Vasoconstriction
23% Login to view PI12 mri inject.pdf
[201 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery
20% Login to view PP69 PHD 2000 Syringe Pump.pdf
[598 KB]
Passive mixing in a three-dimensional serpentine microchannel - Microelectromechanical Systems, Journal of
20% Login to view PP41Infusion Pump.pdf
[496 KB]
Melanocyte-stimulating hormone suppression of systemic inflammatory responses
20% Login to view Permeation and Activation of the M2 Ion Channel.PDF
[248 KB]
Permeation and Activation of the M2 Ion Channel of Influenza A Virus with use of Fast Step Perfusion System
19% Login to view TD0160 1.PDF
[348 KB]
Isotomic Transducer use in Stabilization of Temporally Summated Muscle Contractions in the Lobster (Panulirus) Pyloric System
19% Login to view WR19FA 1.PDF
[220 KB]
Permeation and Activation of the M2 Ion Channel of Influenza A Virus with use of Fast Step Perfusion System
17% Login to view PP33PR 1.PDF
[393 KB]
Micro/nano spacecraft thermal control using a MEMS-based pumped liquid cooling system with use of Programmable syringe pump
   

Back to Top



Manuals Back to Top

Displaying 1 to 4 of 4 results for VIP 3000 Monitoring Systems  

Score

Document

Description

100% Login to view metric system trivia.pdf
[146 KB]
Microsoft Word - Lesson1.doc
86% Login to view Perfusion Tissue Systems Guide.pdf
[105 KB]
New BS4_K_Isolated Organ.qxd
82% Login to view 650073 76 Brain Slice Chmbr Manual.pdf
[706 KB]
Brain Slice Chamber System User's Manual
70% Login to view 650073-0076 Manual.pdf
[285 KB]
Brain Slice Chamber System Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews