Welcome to Harvard Apparatus! — Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources
Shopping Cart Shopping
   Cart
                     My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
Harvard Apparatus

GoDaddy
 

Home Specialty Vertical Ussing/Diffusion Chamber Systems


Larger Views

 

Specialty Vertical Ussing/Diffusion Chamber Systems
The vertical diffusion chamber system is used for transport studies on both filter grown cell monolayers and surgically excised tissue sections. The vertical diffusion chamber system consists of six diffusion chambers, a 12-channel gas manifold and a heat block. 14 general types of vertical chambers are currently available: one for use with cells grown on Snapwell™ membrane supports and the others for use with tissue.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
660001 Specialty Vertical Chamber System with Six 66-0008 - Snapwell™ Chambers -- 5 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• The standard assay for oral bioavailability
• Applications include:
- Drug delivery
- Toxicology
- Pharmacokinetics
- Metabolic studies
- Transport
• US Patented technology numbers: 5, 183, 760 and 5,591,636
• Available in vertical and horizontal system configurations
• Options for using cultured cells or tissue samples
• Manufactured entirely of acrylic for reduced drug absorption/easy cleaning
• Compact configurations
• Up to 24 chambers can be run simultaneously
• Systems are temperature controlled
• Electrode ports connect optional electrodes for monolayer resistance measurements and electrophysiological determinations • Designed for easy placement of Snapwell™ (grown cells) or tissue sections
• All Snapwell™ and tissue diffusion chamber config-urations are compatible with the vertical system, providing versatility and convenience for correlation studies
• Side-by-side orientation prevents a hydrostatic pressure gradient across cell layer
• Distributes gas (user supplied) to the diffusion chambers where media circulation is generated by gas lift, reducing unstirred fluid layers adjacent to cells
• Individual control valves on gas manifold allow independent adjustment of gas flow into each diffusion chamber half-cell
• Closed perfusion capable

The vertical diffusion chamber system is used for transport studies on both filter grown cell monolayers and surgically excised tissue sections. The vertical diffusion chamber system consists of six diffusion chambers, a 12-channel gas manifold and a heat block. 14 general types of vertical chambers are currently available: one for use with cells grown on Snapwell™ membrane supports and the others for use with tissue.
Gas Manifold
The 12-channel gas manifold distributes gas (user supplied) to the Diffusion Chambers where media circulation is generated by gas lift, reducing unstirred fluid layers adjacent to cells.
Heat Block
The dual heating blocks of the Vertical Chamber System provide efficient and precise heating or cooling of the Diffusion Chamber System. Temperature is controlled by use of a circulating water bath. The Heat Block and Gas Manifold allows six simultaneous tests to be run, improving experimental precision.
Electrode Caps
Electrode caps permit proper positioning of electrodes within the vertical perfusion chambers. They are required for the Snapwell™
BS4 66-0008, 8 x 24 mm Tissue 66-0013 and 9 mm Round
BS4 66-0014 chambers. They are not required for the low volume chambers or the horizontal tissue chambers.
Perfusion Caps
The BS4 66-0019 perfusion cap allow the tissue chambers to be perfused with media using a peristaltic or syringe pump. They are required for use with the Snapwell™ 66-0008, 8 x 24 mm Tissue 66-0013, and 9 mm Round 66-0014 chambers. They are not required for the low volume chambers or the horizontal tissue chambers. We offer 14 different vertical diffusion chambers. We also offer a complete system for each chamber that includes the following components:
Catalog No. Qty. Product
66-0009 1 6-Chamber Heating Block
66-0010 1 Clear Front Panel
66-0048 1 12-Channel Gas Manifold
66-0012 1 Retaining Ring Clamp Tool
Specified 6 Vertical Diffusion Chambers


Specifications Back to Top

Specifications660001
660013_gr_il_150.jpg660013_gr_il_150.jpg
Chamber TypeSnapwell™
Exposed Tissue Area1.13 cm2
Working Reservoir Volume4 to 6 ml

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 26 results for Specialty Vertical Ussing/Diffusion Chamber Systems   Page 1  2  3 

Score

Document

Description

100% Login to view Interleukin-12-mediated induction of systemic immunity.pdf
[213 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery and recruitment of activated T cells into the brain produce limited antitumor effects compared with interleukin-2
50% Login to view PP41 y2-Melanocyte-Stimulating Hormone Suppression of Systemic Inflammatory Responses to Endotoxin.pdf
[495 KB]
Melanocyte-stimulating hormone suppression of systemic inflammatory responses
28% Login to view OT01 Chambers.pdf
[963 KB]
Primary Uroepithelial Cultures
28% Login to view Primary Uroepithelial Cultures.pdf
[971 KB]
Primary Uroepithelial Cultures
27% Login to view PP86.pdf
[180 KB]
Dexenfluramine-Induced Systemic Vasoconstriction
25% Login to view PP35 Peristaltic Pump.pdf
[381 KB]
Peristaltic pump use in finding Improvements to parallel plate flow chambers to reduce reagent and cellular requirements
25% Login to view WR16 RC25.pdf
[275 KB]
Recording Chamber use in finding Hypoxic Augmentation of Fast-Inactivating and Persistent Sodium Currents in Rat Caudal Hypothalamic Neurons
23% Login to view Hypoxic Augmentation of Fast-Inactivating and Persistent Sodium.pdf
[281 KB]
Recording Chamber use in finding Hypoxic Augmentation of Fast-Inactivating and Persistent Sodium Currents in Rat Caudal Hypothalamic Neurons
23% Login to view PI12 mri inject.pdf
[201 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery
20% Login to view PP69 PHD 2000 Syringe Pump.pdf
[598 KB]
Passive mixing in a three-dimensional serpentine microchannel - Microelectromechanical Systems, Journal of
   

Back to Top



Manuals Back to Top

Displaying 1 to 3 of 3 results for Specialty Vertical Ussing/Diffusion Chamber Systems  

Score

Document

Description

100% Login to view Ussing Chamber Systems.pdf
[1.5 MB]
Guide to Ussing Chamber Systems
64% Login to view 650073 76 Brain Slice Chmbr Manual.pdf
[706 KB]
Brain Slice Chamber System User's Manual
55% Login to view 650073-0076 Manual.pdf
[285 KB]
Brain Slice Chamber System Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews