Home Molecular Biology Products Centrifuges Microcentrifuges Standard Microcentrifuges Minifuge Centrifuge


Larger Views

 

Minifuge Centrifuge
The standard Mini-fuge accommodates 6 x 1.5/2.0 ml tubes and microcentrifuge filter units directly. Adapters are supplied for spinning 0.5 ml and 0.4 ml tubes.
The new Minifuge S has a rotor that holds two 8 x 0.2 ml PCR strip tubes or 16 individual 0.2 ml tubes. It can be used to spin samples down from the walls or caps of tubes and other applications requiring low g-force.

Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles
Item# Description In Stock Lead Time U.S. List Price Quantity
683354 Minifuge with 6 x 1.5/2.0 ml Rotor and Adapters for 0.5 and 0.4 ml tubes,
120 VAC
-- 10 days View Pricing
Login to Shop
683355 Minifuge with 6 x 1.5/2.0 ml Rotor and Adapters for 0.5 and 0.4 ml tubes,
220 VAC
-- 13 days View Pricing
Login to Shop
683356 Minifuge S with 0.2 ml strip tube rotor, 120 VAC Yes -- View Pricing
Login to Shop
683357 Minifuge S with 0.2 ml strip tube rotor, 220 VAC -- 10 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Spins microtubes or PCR Striptubes
• Two models to choose from:
- Minifuge for 1.5/2.0 ml tubes
- Minifuge S for two 8 x 2.0 ml strip tubes
• Extremely small footprint
• Starts and stops in seconds
• Ideal for quick spin downs, microfiltrations and cell separations

The standard Mini-fuge accommodates 6 x 1.5/2.0 ml tubes and microcentrifuge filter units directly. Adapters are supplied for spinning 0.5 ml and 0.4 ml tubes.

The new Minifuge S has a rotor that holds two 8 x 0.2 ml PCR strip tubes or 16 individual 0.2 ml tubes. It can be used to spin samples down from the walls or caps of tubes and other applications requiring low g-force.

Operating the Mini-fuge is extremely simple - just close the clear lid to start and open to stop. Both units require just 12 x 12 cm of bench space, making them ideal for use in places where space is at a premium. The Minifuges are safe for cold room use. The 220 V units are CE approved.


Specifications Back to Top

Specifications683354683355683356683357
CertificationsCECECECE
Dimensions, H x W x D, English4 x 4.7 x 4.7 in4 x 4.7 x 4.7 in4 x 4.7 x 4.7 in4 x 4.7 x 4.7 in
Dimensions, H x W x D, Metric10.2 x 12 x 12 cm10.2 x 12 x 12 cm10.2 x 12 x 12 cm10.2 x 12 x 12 cm
Electrical120 VAC, 50/60 Hz220 VAC, 50/60 Hz120 VAC, 50/60 Hz220 VAC, 50/60 Hz
Maximum Capacity6 x 1.5 / 2.0 ml tubes6 x 1.5 / 2.0 ml tubes2 8 x 0.2 ml strip tubes2 8 x 0.2 ml strip tubes
Maximum RCF (g-force)2000 x g2000 x g1177 x g, G-force with vary across strip. Specification provides is an average.1177 x g, G-force with vary across strip. Specification provides is an average.
Maximum Speed6000 rpm6000 rpm6000 rpm6000 rpm
ModelMinifugeMinifugeMinifuge SMinifuge S
Rotor6 x 1.5/2.0 ml6 x 1.5/2.0 ml0.2 ml strip tube rotor0.2 ml strip tube rotor
Weight English1 lb1 lb1 lb1 lb
Weight Metric2.2 kg2.2 kg2.2 kg2.2 kg

Back to Top



Journal Articles Back to Top

Displaying 1 to 4 of 4 results for Minifuge Centrifuge  

Score

Document

Description

100% Login to view spincolumn.pdf
[1.1 MB]
Spin Column use in finding Disruption of Centrosome Structure, Chromosome Segragation, and Cytokinesis by Misexpression of Human Cdc14A Phosphatase
100% Login to view spin col empty.pdf
[556 KB]
Solid-phase permethylation of glycans for mass spectrometric analysis
75% Login to view spin col c18.pdf
[295 KB]
Identifying Structural Features of Fibrillar Islet Amyloid Polypeptide Using Site-directed Spin Labeling
50% Login to view spin col activ char.pdf
[1.3 MB]
Profiling of Human Serum Glycans Associated with Liver Cancer and Cirrhosis by IMS-MS
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews