Welcome to Harvard Apparatus! — Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources
Shopping Cart Shopping
   Cart
                     My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
Harvard Apparatus

GoDaddy
 

Home Dialysis / Sample Prep / SPE Chromatographic Products (Disposable) SpinColumns Micro SpinColumns Hydrophobic Packing Material Micro SpinColumns


Larger Views

 

Hydrophobic Packing Material Micro SpinColumns

Micro SpinColumns are best suited for sample volumes from 25 to 75 µl. Centrifugation or filtration under vacuum or pressure can be used to run the sample through the columns. Results obtained from the Micro SpinColumns are highly reproducible and there is minimal sample loss. Each column includes two 2 ml centrifuge tubes plus top cap (for Gel Filtration) or frit.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
744607 Micro SpinColumns, C18 Packing Material, Qty. of 25 -- 5 days View Pricing
Login to Shop
744601 Micro SpinColumns, C18 Packing Material, Qty. of 100 -- 5 days View Pricing
Login to Shop
744608 Micro SpinColumns, C8 Packing Material, Qty. of 25 -- 5 days View Pricing
Login to Shop
744602 Micro SpinColumns, C8 Packing Material, Qty. of 100 -- 5 days View Pricing
Login to Shop
744609 Micro SpinColumns, C4 Packing Material, Qty. of 25 -- 5 days View Pricing
Login to Shop
744603 Micro SpinColumns, C4 Packing Material, Qty. of 100 -- 5 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

Advantages:
• Rapid sample preparation time
• Small sample sizes
• Unrivaled selection of column packing materials; custom packed columns are available on request
• High sample recovery
Applications:
• DNA, protein and peptide purification
• Small molecule, carbohydrate, salt and radiolabel removal
• Nick translation
• Affinity separation
• Buffer exchange

Harvard Apparatus new generation of SpinColumns are designed for the purification of small samples (10 µl to 150 µl) in either single column or high-throughput 96-well format with a standard centrifuge.
Our SpinColumns are pre-filled with a wide selection of chromatographic materials including gel-filtration, ion-exchange, silica-based reverse- and normal-phase materials, as well as specific materials, such as charcoal or cellulose contained by frits and/or caps. The columns can also be pre-filled with custom materials based on customer requests.
Simply place the SpinColumn in a centrifuge tube and centrifuge the tube briefly to separate your sample. The column material binds and purifies the sample according to size and shape, chemical composition, charge or other physiochemical properties.
Harvard Apparatus offers four sizes of SpinColumns to fit your specific applications:
• Ultra-Micro SpinColumns
For sample volumes from 10 µl to 25 µl
• Micro SpinColumns
For sample volumes 25 µl to 75 µl
• Macro SpinColumns
For sample volumes from 75 µl to 150 µl
• 96-Well SpinColumns
For high throughput applications with sample volumes from 25 µl to 100 µl
Micro SpinColumns are best suited for sample volumes from 25 to 75 µl. Centrifugation or filtration under vacuum or pressure can be used to run the sample through the columns. Results obtained from the Micro SpinColumns are highly reproducible and there is minimal sample loss. Each column includes two 2 ml centrifuge tubes plus top cap (for Gel Filtration) or frit.


Specifications Back to Top

Specifications744607744601744608744602744609744603
Packing MaterialC18 Packing MaterialC18 Packing MaterialC8 Packing MaterialC8 Packing MaterialC4 Packing MaterialC4 Packing Material
Sample Size Metric25 to 75 ?l25 to 75 ?l25 to 75 ?l25 to 75 ?l25 to 75 ?l25 to 75 ?l

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 12 results for Hydrophobic Packing Material Micro SpinColumns   Page 1  2 

Score

Document

Description

100% Login to view micro eq dial2.pdf
[1.1 MB]
Control of electrostatic interactions between F-actin and genetically modified lysozyme in aqueous media
56% Login to view micro eq dial1.pdf
[354 KB]
Equilibrium Dialyzer for use in finding Differential ATP binding and Intrinsic ATP Hydrolysis
45% Login to view spin col c18.pdf
[295 KB]
Identifying Structural Features of Fibrillar Islet Amyloid Polypeptide Using Site-directed Spin Labeling
39% Login to view PP33PR 1.PDF
[393 KB]
Micro/nano spacecraft thermal control using a MEMS-based pumped liquid cooling system with use of Programmable syringe pump
35% Login to view PP110 A Study of Polyethoxylated Alkylphenols by Packed Column Supercritical Fluid Chromatography.pdf
[1.1 MB]
Journal of Chromatographic Science
21% Login to view PP33 Micro-Nano Spacecraft Thermal Control Using a MEMS-Based Pumped Liquid Cooling System.pdf
[299 KB]
Syringe Harvard Apparatus 22 Feeder use in finding Particle morphology of carboxylated poly composite latex particles
13% Login to view Airway Surface Liquid Osmolality Measured using Fluorophore-encapsulated Liposomes.pdf
[258 KB]
Airway Surface Liquid Osmolality Measured during Fluorophore-encapsulated Liposomes
13% Login to view PDMI03 2003microinc.pdf
[251 KB]
Airway Surface Liquid Osmolality Measured during Fluorophore-encapsulated Liposomes
13% Login to view spin col empty.pdf
[556 KB]
Solid-phase permethylation of glycans for mass spectrometric analysis
13% Login to view spincolumn.pdf
[1.1 MB]
Spin Column use in finding Disruption of Centrosome Structure, Chromosome Segragation, and Cytokinesis by Misexpression of Human Cdc14A Phosphatase
   

Back to Top



Manuals Back to Top

Displaying 1 to 2 of 2 results for Hydrophobic Packing Material Micro SpinColumns  

Score

Document

Description

100% Login to view Micro SpinColumn.pdf
[43 KB]
Micro SpinColumn
88% Login to view Ultra-Micro SpinColumn.pdf
[45 KB]
Ultra-Micro SpinColumn
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews