Home Product Catalogs Syringe Pumps/Peristaltic Pumps Syringe Pumps Infuse/Withdraw Standard Infuse/Withdraw Harvard Pump 11 Plus Advanced Single Syringe with Dual RS-232 Syringe Pumps
 


Larger Views

Standard Infuse/Withdraw Harvard Pump 11 Plus Advanced Single Syringe with Dual RS-232 Syringe Pumps
The Pump 11 Plus family of pumps are our more basic pumps, but provide the precision flow that Harvard Apparatus pumps are known for. Select from either 1 or 2 syringe models and from basic infusion only or the more advanced infuse/withdraw models. The infuse/withdraw models also have RS-232 communictions.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
702211 Harvard Pump 11 Plus Advanced Single Syringe with Dual RS-232 -- 5 days View Pricing
Login to Shop
702212 Harvard Pump 11 Plus Advanced Dual Syringe with Dual RS-232 -- 5 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• NEW brighter display: easier to read and use
• NEW volume dispense feature
• Single or dual syringe models available
• Small, compact size

Harvard Apparatus’ Syringe Pump 11 Plus combines smoother flow and updated features to create a high performance syringe pump with a basic syringe pump price!

Bright Display and Easy-To-Use Interface
A new, two-line 16 character vacuum fluorescent display and six membrane keys make this a powerful, easy-to-use syringe pump. Only two entries are required to start pumping; Syringe ID and flow rate. The flow rate can be changed while the pump is running.

Two Modes of Operation,
Constant Flow Rate & Volume Dispense
The new Pump 11 Plus will operate continuously in RATE mode or accurately dispense a specific amount of fluid in VOLUME mode.

Versatile
Select from two different models. The standard Pump 11 Plus model has the following features:
• Infusion Only
• End of Travel Limit Stop
• Anti-Siphon Bracket

The Pump 11 Plus Advanced model has the same features as the standard model, but also includes:
• Infusion/Withdrawal
• Dual RS-232 Communications

Both models are available with either a single syringe configuration or dual syringe configuration. Select the pump that best fits your application.

Non-Volatile Memory
New micro-stepping pump profiles deliver very smooth and consistent flow over the entire flow rate range. These pumps now feature non-volatile memory. The pump remembers its last syringe size, flow rate used and configuration settings. An advanced universal power supply means there is no need to change AC line switches, fuses or wires.

The new Pump 11 Plus will operate on any AC line voltage from 95 VAC to 240 VAC, either 50 or 60 Hz. The new Pump 11 Plus offers the same power failure mode as our PHD 22/2000 syringe pump series. In a power failure the pump can either Resume or Stop pumping when power is returned.

Safety
The Pump 11 Plus motor will not shut itself off in case of overload, rather it will remain in a stalled position with no damage. An adjustment collar on the guide rod prevents the syringe plunger from hitting bottom.

CE Mark Approved
The new Pump 11 Plus meets all relevant European EMC and Safety requirements for laboratory equipment..


Specifications Back to Top

Specifications702211702212
# of Syringes12
Accuracy+/- 0.5 %+/- 0.5 %
Average Linear Force16 lbs16 lbs
CommunicationsRS-232RS-232
Communications Level11
Depth English4.5 in4.5 in
Depth Metric11.4 cm11.4 cm
DisplayVacuum fluorescent, 2-line, 16 characterVacuum fluorescent, 2-line, 16 character
Flow Rate Maximum26.56 ml/min7.909 ml/min
Flow Rate Minimum0.0014 µl/hr0.0014 µl/hr
Height English5 in5 in
Height Metric13 cm13 cm
Input Power12 VDC, 1.5 A, 18 W12 VDC, 1.5 A, 18 W
Motor1/4 microstepping, 0.9° micro step angle motor1/4 microstepping, 0.9° micro step angle motor
Motor Stepper 1 Revolution of Lead Screw3,200 at 1/4 stepping3,200 at 1/4 stepping
Net Weight English4.6 lb4.6 lb
Net Weight Metric2.1 kg2.1 kg
Non Volatile MemoryStorage of all settingsStorage of all settings
PressureLowLow
Pump ConfigurationStandardStandard
Pump FunctionInfuse/WithdrawInfuse/Withdraw
Pusher Travel Rate Maximum47.6 mm/min47.6 mm/min
Pusher Travel Rate Minimum2.9068 µm/min2.9068 µm/min
RS-232OptionOption
Reproducibility+/- 0.1 %+/- 0.1 %
Step Rate Maximum416.7 µsec/step416.7 µsec/step
Step Rate Minimum6.8 sec/step6.8 sec/step
Step Resolution0.8 µm/step0.8 µm/step
Syringe Rack TypeStandard RackStandard Rack
Syringe Size Maximum60 ml10 ml
Syringe Size Minimum0.5 µl0.5 µl
TTLNoNo
TypeMicroprocessor single or dual syringe, infusion only or infuse/withdrawMicroprocessor single or dual syringe, infusion only or infuse/withdraw
Voltage RangeUniversal input 100/250 VAC, 50/60 Hz, 18 W (use only Harvard Apparatus approved supply and line cord)Universal input 100/250 VAC, 50/60 Hz, 18 W (use only Harvard Apparatus approved supply and line cord)
Width English9 in9 in
Width Metric22.9 cm22.9 cm

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 105 results for Standard Infuse/Withdraw Harvard Pump 11 Plus Advanced Single Syringe with Dual RS-232 Syringe Pumps   Page 1  2  3  4  5  6  7  8  9  10  11 

Score

Document

Description

100% Login to view PP06 Molecular Clocks.pdf
[108 KB]
PHD 22/2000 Syringe Pump used in finding Molecular Clocks
86% Login to view PP16 Developing the Atomic Force Microscope for Studies of Living Cells.pdf
[325 KB]
Infusion/Withdrawal Pump use in Developing the atomic force miscoscope for studies of living cells
80% Login to view PP81 A Protocol For High-Throughput Drug Mixture Quantitation.pdf
[306 KB]
Microdrive Pump use in Coincident Activation of NMDA and Dopamine D1 Receptors within the Nucleus Accumbens Core Is Required for Appetitive Instrumental Learning
79% Login to view PP28 Electrospray Ionization Tandem Mass Spectrometric Study of Salt Cluster ions.pdf
[422 KB]
Electrospray ionization tandem mass spectrometric study of salt cluster ions with use of Model 11 syringe pump
77% Login to view PP12 Pump 11 Syringe.pdf
[179 KB]
Syringe Pump use in Studies of potential-dependent metallothionein adsorptions using a low-volume electrochemical quartz crystal microbalance flow cell
75% Login to view PP100 Nonstriatal Dopamine D1 Receptors Regulate Striatal Acetylcholine Release In Vivo.pdf
[215 KB]
Double Syringe Pump use in finding Effects of hyperglycemia
75% Login to view PP99 Microcirculation in Intestinal Villi.pdf
[211 KB]
Syringe Pump use in finding Microcirculation in Intestinal Villi
75% Login to view PP109 Measurement of Intravascular Na+ During Increased CBF Using 23Na NMR with a Shift Reagant.pdf
[135 KB]
Infusion Pump use in finding Measurement of intravascular Na+ during increased CBF using 23Na NMR with a shift reagent
70% Login to view PP08 NO Supports Right Ventricular Flow Dominance and Whole Body O2 Utilization in Midgestation Fetal Labms.pdf
[173 KB]
PII: S0022-0728(01)00602-7
69% Login to view PP119 Coupling of Liquid Chromatographic Polymer Separations with Time-of-Flight Mass Spectrometry.pdf
[102 KB]
Syringe Pump use in Coupling of Liquid Chromatographic Polymer Separations with Time-of-Flight Mass Spectrometry
   

Back to Top



Manuals Back to Top

Displaying 1 to 3 of 3 results for Standard Infuse/Withdraw Harvard Pump 11 Plus Advanced Single Syringe with Dual RS-232 Syringe Pumps  

Score

Document

Description

100% Login to view 703005 PHD ULTRA Manual.pdf
[2.4 MB]
PHD Ultra Syringe Pumps Manual - Standard/Remote/Programmable
96% Login to view Pump11 Plus.pdf
[1.1 MB]
Model 11 Plus Syringe Pump Manual
59% Login to view 703005 PHD ULTRA Quickstart.pdf
[173 KB]
PHD Ultra Syringe Pumps Quickstart Guide - Standard/Remote/Programmable
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews