Welcome to Harvard Apparatus! — Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources
Shopping Cart Shopping
   Cart
                     My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
Harvard Apparatus

GoDaddy
 

Home Biological Measurement Products pH Meters pH Controllers pH Controllers with Single Setpoint


Larger Views

 

pH Controllers with Single Setpoint
pH 500 series of controllers offer exceptional value for your money. They are simple-to-operate, microprocessor-based process meters packed with features for the biological laboratory. For more flexibility and better resolution than chart recorders, any two points between 0 and 14 pH can be chosen to correspond to the analog output spans. Several pH 500 models are equipped with a bi-directional RS232C port. Push button password programming prevents tampering. The microprocessor memory is fully programmable and has 3 months backup power supply. The Fail Safe Alarm system protects the pH 500 against the pitfalls of process control, like power interruption or line failure. With pH 500 quick 1, 2 or 3 point calibration at pH 4.01, 7.01 and 10.01 comes standard. The temperature can be manually or automatically compensated for. Increased automation has made computer compatibility a necessity for process control instrumentation.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
722003 pH 500 Controller, Single Setpoint, Analog Output, On/Off Controls, 115 VAC, 60 Hz -- 10 days View Pricing
Login to Shop
722004 pH 500 Controller, ingle setpoint, Analog Output, On/Off Controls, 230 VAC, 50 Hz -- 10 days View Pricing
Login to Shop
722005 pH 500 Controller, Single Setpoint, RS232 Output, On/Off Controls, 115 VAC, 60 Hz Yes -- View Pricing
Login to Shop
722006 pH 500 Controller, Single Setpoint, RS232 Output, On/Off Controls, 230 VAC, 50 Hz -- 10 days View Pricing
Login to Shop
722007 pH 500 Controller, Single Setpoint, Analog Output, Proportional Controls, 115 VAC, 60 Hz -- 10 days View Pricing
Login to Shop
722008 pH 500 Controller, Single Setpoint, Analog Output, Proportional Controls, 230 VAC, 50 Hz -- 10 days View Pricing
Login to Shop
722009 pH 500 Controller, Single Setpoint, RS232 Output, Proportional Controls, 115 VAC, 60 Hz -- 10 days View Pricing
Login to Shop
722010 pH 500 Controller, Single Setpoint, RS232 Output, Proportional Controls, 230 VAC, 50 Hz -- 10 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Hi-tech pH 500 controller
• The new measure of value
• Simple to operate
• Microprocessor-based

pH 500 series of controllers offer exceptional value for your money. They are simple-to-operate, microprocessor-based process meters packed with features for the biological laboratory. For more flexibility and better resolution for chart recorders, any two points between 0 and 14 pH can be chosen to correspond to the analog output spans. Several pH 500 models are equipped with a bi-directional RS232C port. Push button password programming prevents tampering. The microprocessor memory is fully programmable and has 3 months backup power supply. The Fail Safe Alarm system protects the pH 500 against the pitfalls of process control, like power interruption or line failure. With pH 500 quick 1, 2 or 3 point calibration at pH 4.01, 7.01 and 10.01 comes standard. The temperature can be manually or automatically compensated for. Increased automation has made computer compatibility a necessity for process control instrumentation.
This unit can be adapted to control the pH of biological preparations such as cell cultures by controlling flow of a pH reducing gas such as CO2. The CO2 gas can be regulated by on/off proportional control to save gas.


Specifications Back to Top

Specifications722003722004722005722006722007722008722009722010
Accuracy of mV at 20°C/68°F±0.5±0.5±0.5±0.5±0.5±0.5±0.5±0.5
Accuracy of pH at 20°C/68°F±0.02±0.02±0.02±0.02±0.02±0.02±0.02±0.02
Accuracy of temperature (°C) at 20°C/68°F±0.5°±0.5°±0.5°±0.5°±0.5°±0.5°±0.5°±0.5°
Analog OutputGalvanically isolated 0 to 1mA, 0 to 20mA and 4 to 20mA (max resistive load 1 KW), 0 to 5 VDC, 1 to 5 VDC and 0 to 10 VDC (min resistive load 1 KW)Galvanically isolated 0 to 1mA, 0 to 20mA and 4 to 20mA (max resistive load 1 KW), 0 to 5 VDC, 1 to 5 VDC and 0 to 10 VDC (min resistive load 1 KW)Galvanically isolated 0 to 1mA, 0 to 20mA and 4 to 20mA (max resistive load 1 KW), 0 to 5 VDC, 1 to 5 VDC and 0 to 10 VDC (min resistive load 1 KW)Galvanically isolated 0 to 1mA, 0 to 20mA and 4 to 20mA (max resistive load 1 KW), 0 to 5 VDC, 1 to 5 VDC and 0 to 10 VDC (min resistive load 1 KW)Galvanically isolated 0 to 1mA, 0 to 20mA and 4 to 20mA (max resistive load 1 KW), 0 to 5 VDC, 1 to 5 VDC and 0 to 10 VDC (min resistive load 1 KW)Galvanically isolated 0 to 1mA, 0 to 20mA and 4 to 20mA (max resistive load 1 KW), 0 to 5 VDC, 1 to 5 VDC and 0 to 10 VDC (min resistive load 1 KW)Galvanically isolated 0 to 1mA, 0 to 20mA and 4 to 20mA (max resistive load 1 KW), 0 to 5 VDC, 1 to 5 VDC and 0 to 10 VDC (min resistive load 1 KW)Galvanically isolated 0 to 1mA, 0 to 20mA and 4 to 20mA (max resistive load 1 KW), 0 to 5 VDC, 1 to 5 VDC and 0 to 10 VDC (min resistive load 1 KW)
Battery Type115V ±10% VAC; 60 Hz230V ±10% VAC; 50 Hz115V ±10% VAC; 60 Hz230V ±10% VAC; 50 Hz115V ±10% VAC; 60 Hz230V ±10% VAC; 50 Hz115V ±10% VAC; 60 Hz230V ±10% VAC; 50 Hz
Digital OutputRS232 bi-directional opto-isolatedRS232 bi-directional opto-isolatedRS232 bi-directional opto-isolatedRS232 bi-directional opto-isolatedRS232 bi-directional opto-isolatedRS232 bi-directional opto-isolatedRS232 bi-directional opto-isolatedRS232 bi-directional opto-isolated
Environment (RH)85% non-condensing85% non-condensing85% non-condensing85% non-condensing85% non-condensing85% non-condensing85% non-condensing85% non-condensing
Environment (°C)0° to 50°0° to 50°0° to 50°0° to 50°0° to 50°0° to 50°0° to 50°0° to 50°
Environment (°F)32° to 122°32° to 122°32° to 122°32° to 122°32° to 122°32° to 122°32° to 122°32° to 122°
Input Impedance1012?1012?1012?1012?1012?1012?1012?1012?
LoggingAutomatic (with Pt 100) or manual from -9.9° to 120°Automatic (with Pt 100) or manual from -9.9° to 120°Automatic (with Pt 100) or manual from -9.9° to 120°Automatic (with Pt 100) or manual from -9.9° to 120°Automatic (with Pt 100) or manual from -9.9° to 120°Automatic (with Pt 100) or manual from -9.9° to 120°Automatic (with Pt 100) or manual from -9.9° to 120°Automatic (with Pt 100) or manual from -9.9° to 120°
Meter Dimensions (H x W x D) English6.7 x 5.7 x 5.7 in6.7 x 5.7 x 5.7 in6.7 x 5.7 x 5.7 in6.7 x 5.7 x 5.7 in6.7 x 5.7 x 5.7 in6.7 x 5.7 x 5.7 in6.7 x 5.7 x 5.7 in6.7 x 5.7 x 5.7 in
Meter Dimensions (H x W x D) Metric170 x 144 x 144170 x 144 x 144170 x 144 x 144170 x 144 x 144170 x 144 x 144170 x 144 x 144170 x 144 x 144170 x 144 x 144
Panel Output English5.5 x 5.55.5 x 5.55.5 x 5.55.5 x 5.55.5 x 5.55.5 x 5.55.5 x 5.55.5 x 5.5
Panel Output Metric140 x 140 mm140 x 140 mm140 x 140 mm140 x 140 mm140 x 140 mm140 x 140 mm140 x 140 mm140 x 140 mm
Readout4° digit dual level LCD with graphic symbols and messages4° digit dual level LCD with graphic symbols and messages4° digit dual level LCD with graphic symbols and messages4° digit dual level LCD with graphic symbols and messages4° digit dual level LCD with graphic symbols and messages4° digit dual level LCD with graphic symbols and messages4° digit dual level LCD with graphic symbols and messages4° digit dual level LCD with graphic symbols and messages
Setpoint Relays1 or 2; SPST NO contact outputs 5 A-250 VAC, 5 A-30 VDC (resistive load)1 or 2; SPST NO contact outputs 5 A-250 VAC, 5 A-30 VDC (resistive load)1 or 2; SPST NO contact outputs 5 A-250 VAC, 5 A-30 VDC (resistive load)1 or 2; SPST NO contact outputs 5 A-250 VAC, 5 A-30 VDC (resistive load)1 or 2; SPST NO contact outputs 5 A-250 VAC, 5 A-30 VDC (resistive load)1 or 2; SPST NO contact outputs 5 A-250 VAC, 5 A-30 VDC (resistive load)1 or 2; SPST NO contact outputs 5 A-250 VAC, 5 A-30 VDC (resistive load)1 or 2; SPST NO contact outputs 5 A-250 VAC, 5 A-30 VDC (resistive load)
Temperature Range (°C)-9.9° to 120.0°-9.9° to 120.0°-9.9° to 120.0°-9.9° to 120.0°-9.9° to 120.0°-9.9° to 120.0°-9.9° to 120.0°-9.9° to 120.0°
Temperature Resolution (°C)0.1°0.1°0.1°0.1°0.1°0.1°0.1°0.1°
Typical EMC Deviation of Temperature (°C)±0.5°±0.5°±0.5°±0.5°±0.5°±0.5°±0.5°±0.5°
Typical EMC Deviation of mV±10±10±10±10±10±10±10±10
Typical EMC Deviation of pH±0.02±0.02±0.02±0.02±0.02±0.02±0.02±0.02
Weight English3.5 lb3.5 lb3.5 lb3.5 lb3.5 lb3.5 lb3.5 lb3.5 lb
Weight Metric1.6 kg1.6 kg1.6 kg1.6 kg1.6 kg1.6 kg1.6 kg1.6 kg
mV Range-600.0 t0 600.0-600.0 t0 600.0-600.0 t0 600.0-600.0 t0 600.0-600.0 t0 600.0-600.0 t0 600.0-600.0 t0 600.0-600.0 t0 600.0
mV Resolution0.20.20.20.20.20.20.20.2
pH Calibration1, 2 or 3 point with buffers 4.01, 7.01 and 10.011, 2 or 3 point with buffers 4.01, 7.01 and 10.011, 2 or 3 point with buffers 4.01, 7.01 and 10.011, 2 or 3 point with buffers 4.01, 7.01 and 10.011, 2 or 3 point with buffers 4.01, 7.01 and 10.011, 2 or 3 point with buffers 4.01, 7.01 and 10.011, 2 or 3 point with buffers 4.01, 7.01 and 10.011, 2 or 3 point with buffers 4.01, 7.01 and 10.01
pH Range0.00 to 14.000.00 to 14.000.00 to 14.000.00 to 14.000.00 to 14.000.00 to 14.000.00 to 14.000.00 to 14.00
pH Resolution0.010.010.010.010.010.010.010.01

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 34 results for pH Controllers with Single Setpoint   Page 1  2  3  4 

Score

Document

Description

100% Login to view Noninvasive measurement of the pH of the endoplasmic reticulum.PDF
[372 KB]
Noninvasive measurement of the pH of the endoplasmic reticulum at rest and during calcium release
30% Login to view VT14 Rodent Ventilator.pdf
[440 KB]
PDMI-2 Microincubator use in Airway surface liquid pH in well-differentiated airway epithelial cell cultures and mouse trachea
25% Login to view dispo eq dial3.pdf
[868 KB]
An mRNA structure that controls gene expression by binding S-adenosylmethionine
24% Login to view PDMI02 1.PDF
[360 KB]
Noninvasie measurement of the pH of the endoplasmic reticulim at rest and during calcium release
17% Login to view VT18 PDMI2 Microincubator.pdf
[456 KB]
PDMI-2 Microincubator use in Airway surface liquid pH in well-differentiated airway epithelial cell cultures and mouse trachea
16% Login to view VT23 Inhibition Shapes Frequency Response Areas with Small Animal Ventilator.pdf
[673 KB]
Inhibition Shapes Frequency Response Areas with Small Animal Ventilator
16% Login to view VT31 Sickle RBC's and NOS Inhibition decrease rat cerebral blood flow.pdf
[515 KB]
Sickle RBC's and NOS Inhibition decrease rat cerebral blood flow
16% Login to view VT11 Effects of Concentrated Ambient Particles in rats and Hamsters with Small Animal Respirator.pdf
[874 KB]
Effects of Concentrated Ambient Particles in rats and Hamsters with Small Animal Respirator
16% Login to view VT36 Ventilator use in finding Water Permeability of Capillaries in the SFO.pdf
[467 KB]
Ventilator use in finding Water Permeability of Capillaries in the SFO
16% Login to view VT21 Ligation of bronchial artery in sheep attenuates early pulmonary changes following exposure to smoke.pdf
[183 KB]
Rodent Ventilator use in finding arterior wall PO2 and nitric oxide release during sympathetic vasoconstriction in the rat intestine
   

Back to Top



Manuals Back to Top

Displaying 1 to 3 of 3 results for pH Controllers with Single Setpoint  

Score

Document

Description

100% Login to view 702116 C02 pH Controller Manual.pdf
[356 KB]
CO2/pH Controller User's Manual
100% Login to view 500200 Temp Control Manual.pdf
[670 KB]
Temperature Controller Instruction Manual
64% Login to view TC 324B Manual.pdf
[508 KB]
Single Channel Heater Controller User's Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews