Home Microincubation / Microinjectors Microinjection Syringes Screw Actuated Hamilton Syringe


Larger Views

 

Screw Actuated Hamilton Syringe
This screw actuated syringe is a micrometer-actuated syringe mechanism mounted on a small base. This syringe is for
oil/air-assisted micro-injections and micro-aspirations. Its compact dimensions enable it to be ergonomically positioned next to the control lever of a micromanipulator to facilitate single-handed operation of both instruments.

Search for Product in current catalog
Item Listing Full Description Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
690107 Screw Actuated Micrometer Driven Hamilton Syringe -- 13 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Ideal for oil-filled injection/aspiration
• Easy to use
• Hamilton syringe incorporated
• Accurate
• Sensitive control
• Low dead-air volume
• High suction/pressure
• Easy to exchange or replace the syringe

This screw actuated syringe is a micrometer-actuated syringe mechanism mounted on a small base. This syringe is for
oil/air-assisted micro-injections and micro-aspirations. Its compact dimensions enable it to be ergonomically positioned next to the control lever of a micromanipulator to facilitate single-handed operation of both instruments.
Suction/injection is achieved by using the rotary-actuator with a fine micrometer-thread, which has a 15 mm movement range. A Hamilton 1 ml Gastight glass syringe with a Luer-taper is incorporated. A Luer-taper hypodermic needle is mounted on the taper of the Hamilton syringe. The syringe is connected by hard polyethylene tubing to a micropipette, which in turn, may be fitted to a micromanipulator or similar instrument. The 1 ml Hamilton syringe can be easily exchanged for any other Hamilton 1700 syringe series including the 1000, 500, 200, 100 and 50 µl sizes.


Journal Articles Back to Top

Displaying 1 to 10 of 69 results for Screw Actuated Hamilton Syringe   Page 1  2  3  4  5  6  7 

Score

Document

Description

100% Login to view PP07 Syringe Pump.pdf
[305 KB]
Syringe Pump use in Mapping the Glycoprotein Ib-binding Site in the von Willebrand Factor A1 Domain
99% Login to view PP53 Syringe Pump22.pdf
[525 KB]
Syringe Pump use in finding Choroid plexus epithelial expression of MDRI P glycoprotein
97% Login to view PP06 PHD2000 Syringe Pump.pdf
[104 KB]
PHD 200 Syringe Pump use in finding Molecular Clocks
92% Login to view PP66 Syringe MS Pump.pdf
[261 KB]
Characterization of a novel Sepia officinalis neuropeptide with use of a Syringe Pump
87% Login to view PP05 Syringe MS Pump.pdf
[201 KB]
Electrospray Ionization Mass Spectrometric Anlyses of Phospholipids from Rat and Human Pancreatic Islets and Subcellular Membranes with us of Harvard Syringe Pump
87% Login to view PP34 Syringe 22 Feeder.pdf
[307 KB]
Syringe Harvard Apparatus 22 Feeder use in finding Particle morphology of carboxylated poly composite latex particles
85% Login to view PP15 Model 22 Syringe Pump.pdf
[225 KB]
Syringe Infusion Pump use for An Investigation of Three-Phase Flow
85% Login to view PP73 Syringe Pump22 infuse.pdf
[646 KB]
Harvard 22 Syringe Pump use in finding set-point model with oscillatory behavior predicts the time course of 8-OH-DPAT-induced hypothermia
79% Login to view PP38 Model 22 Syringe Pump.pdf
[101 KB]
Binding Energies of the Silver Ion with use of Syringe Pump
69% Login to view PP36 Syringe Pump.pdf
[133 KB]
Surface Micromachine Microfluidics: Design, Fabrication, Packa
   

Back to Top



Manuals Back to Top

Displaying 1 to 4 of 4 results for Screw Actuated Hamilton Syringe  

Score

Document

Description

100% Login to view Syringe Selector.pdf
[127 KB]
Manual & Automatic Syringe Selector Manual
60% Login to view syringe dimension chart.pdf
[51 KB]
syringe dimension chart.idw
58% Login to view 551028 SSteel Syringes Manual.pdf
[18 KB]
Stainless Steel Syringe User's Manual
50% Login to view 702217 Nanomite Syringe Pump Manual.pdf
[893 KB]
Nanomite Syringe Pump User's Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews