Home Microincubation / Microinjectors Microinjection Syringes Screw Actuated Syringe


Larger Views

 

Screw Actuated Syringe
These air-assisted microinjection/micro-aspiration syringes provide the user with sensitive control and an extremely low dead-air volume. The capacity of the syringe is 10 ml. When required, the syringes can be used to generate high pressure or suction.
Search for Product in current catalog
Item Listing Full Description Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
690105 Screw Actuated Air Syringe -- 10 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• For air-assisted micro-injection and micro-aspiration
• Uncomplicated and easy to use
• Accurate
• Sensitive control
• High suction/pressure

These air-assisted microinjection/micro-aspiration syringes provide the user with sensitive control and an extremely low dead-air volume. The capacity of the syringe is 10 ml. When required, the syringes can be used to generate high pressure or suction.
The screw-actuated syringe is a small compact unit incorporated into a heavy circular base. Its convenient dimensions enable it to be ergonomically positioned next to the control lever of a micromanipulator to facilitate single-handed operation of both instruments.
The syringe is connected by hard polyethylene tubing to a micropipette, which in turn, may be fitted to a micromanipulator or
positioning device. Suction/injection is obtained by turning the metal colored actuator screw-control on the top of the syringe. The syringe provides a solution to the problem of capillary action when working with small micropipettes. A small balance (equilibrating) pressure can be maintained to offset the effects of capillary action. A conveniently situated release-button on-top of the screw-control is provided to achieve equilibration.


Journal Articles Back to Top

Displaying 1 to 10 of 69 results for Screw Actuated Syringe   Page 1  2  3  4  5  6  7 

Score

Document

Description

100% Login to view PP07 Syringe Pump.pdf
[305 KB]
Syringe Pump use in Mapping the Glycoprotein Ib-binding Site in the von Willebrand Factor A1 Domain
99% Login to view PP53 Syringe Pump22.pdf
[525 KB]
Syringe Pump use in finding Choroid plexus epithelial expression of MDRI P glycoprotein
97% Login to view PP06 PHD2000 Syringe Pump.pdf
[104 KB]
PHD 200 Syringe Pump use in finding Molecular Clocks
92% Login to view PP66 Syringe MS Pump.pdf
[261 KB]
Characterization of a novel Sepia officinalis neuropeptide with use of a Syringe Pump
87% Login to view PP05 Syringe MS Pump.pdf
[201 KB]
Electrospray Ionization Mass Spectrometric Anlyses of Phospholipids from Rat and Human Pancreatic Islets and Subcellular Membranes with us of Harvard Syringe Pump
87% Login to view PP34 Syringe 22 Feeder.pdf
[307 KB]
Syringe Harvard Apparatus 22 Feeder use in finding Particle morphology of carboxylated poly composite latex particles
85% Login to view PP15 Model 22 Syringe Pump.pdf
[225 KB]
Syringe Infusion Pump use for An Investigation of Three-Phase Flow
85% Login to view PP73 Syringe Pump22 infuse.pdf
[646 KB]
Harvard 22 Syringe Pump use in finding set-point model with oscillatory behavior predicts the time course of 8-OH-DPAT-induced hypothermia
79% Login to view PP38 Model 22 Syringe Pump.pdf
[101 KB]
Binding Energies of the Silver Ion with use of Syringe Pump
69% Login to view PP36 Syringe Pump.pdf
[133 KB]
Surface Micromachine Microfluidics: Design, Fabrication, Packa
   

Back to Top



Manuals Back to Top

Displaying 1 to 4 of 4 results for Screw Actuated Syringe  

Score

Document

Description

100% Login to view Syringe Selector.pdf
[127 KB]
Manual & Automatic Syringe Selector Manual
60% Login to view syringe dimension chart.pdf
[51 KB]
syringe dimension chart.idw
58% Login to view 551028 SSteel Syringes Manual.pdf
[18 KB]
Stainless Steel Syringe User's Manual
50% Login to view 702217 Nanomite Syringe Pump Manual.pdf
[893 KB]
Nanomite Syringe Pump User's Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews