Home Biological Measurement Products Dissolved Oxygen Meters Oxygen Electrodes for Harvard/Instech Oxygen Monitoring System


Larger Views

 

Oxygen Electrodes for Harvard/Instech Oxygen Monitoring System
Our Clark style polarographic electrode measures 41.3 mm (1.625 in) long by 3.2 mm (0.125 in) diameter. The cathode is an exposed section of 0.1 mm (0.005 in) pure platinum wire in a fused glass seal.
Search for Product in current catalog
Item Listing Full Description Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
610134 Standard Electrode with YSI Cable (Replaces YSI Part Numbers 5357 and 5358) -- 10 days View Pricing
Login to Shop
610136 Thurman Style Electrode -- 10 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top


Our Clark style polarographic electrode measures 41.3 mm (1.625 in) long by 3.2 mm (0.125 in) diameter. The cathode is an exposed section of 0.1 mm (0.005 in) pure platinum wire in a fused glass seal.
To prepare the electrode, a sheet of polyethylene membrane material is sealed with an O-ring over a drop of KCl solution on the electrode tip. The temperature coefficient is 4%/1°C, so temperature stability in your system is important.
Each electrode includes a cable which is attached to the electrode and sealed to prevent salt contamination, a sleeve to use the electrode in our chamber system, a sleeve to use the electrode outside the chamber, extra membrane material and o-rings, a membrane installation tool, and polishing paper and Scotch-Brite for maintaining the electrode.
This electrode is compatible with the 56-5077 amplifier and YSI’s model 5300 oxygen monitor (the cables are different, so specify the appropriate part number). We also supply a special Thurman-style electrode for existing liver perfusion set-ups.


Journal Articles Back to Top

Displaying 1 to 9 of 9 results for Oxygen Electrodes for Harvard/Instech Oxygen Monitoring System  

Score

Document

Description

100% Login to view HS15 Myoglobin facilitates oxygen diffusion.pdf
[631 KB]
Isolated Heart Apparatus use in Myoglobin facilitating oxygen diffusion
95% Login to view HB01 Assessment of Tissue Oxygen Tension.pdf
[270 KB]
Homeothermic Blanket Assessment of tissue oxygen tension
73% Login to view HB01 homethermic blanket.pdf
[259 KB]
Homeothermic Blanket Assessment of tissue oxygen tension
47% Login to view HS15 isolated heart app.pdf
[632 KB]
Isolated Heart Apparatus use in Myoglobin facilitating oxygen diffusion
26% Login to view Interleukin-12-mediated induction of systemic immunity.pdf
[213 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery and recruitment of activated T cells into the brain produce limited antitumor effects compared with interleukin-2
25% Login to view PP38 Binding Energies of the Silver Ion to Small Oxygen-Containing Ligands.pdf
[107 KB]
Binding Energies of the Silver Ion with use of Syringe Pump
13% Login to view PP41 y2-Melanocyte-Stimulating Hormone Suppression of Systemic Inflammatory Responses to Endotoxin.pdf
[495 KB]
Melanocyte-stimulating hormone suppression of systemic inflammatory responses
11% Login to view PP101 2002vent.pdf
[210 KB]
Double Syringe Pump use in finding Effects of hyperglycemia
11% Login to view PP38 Model 22 Syringe Pump.pdf
[101 KB]
Binding Energies of the Silver Ion with use of Syringe Pump
   

Back to Top



Manuals Back to Top

Displaying 1 to 4 of 4 results for Oxygen Electrodes for Harvard/Instech Oxygen Monitoring System  

Score

Document

Description

100% Login to view metric system trivia.pdf
[146 KB]
Microsoft Word - Lesson1.doc
86% Login to view Perfusion Tissue Systems Guide.pdf
[105 KB]
New BS4_K_Isolated Organ.qxd
82% Login to view 650073 76 Brain Slice Chmbr Manual.pdf
[706 KB]
Brain Slice Chamber System User's Manual
71% Login to view 650073-0076 Manual.pdf
[285 KB]
Brain Slice Chamber System Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews