Welcome to Harvard Apparatus! — Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources
Shopping Cart Shopping
   Cart
                     My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
Harvard Apparatus

GoDaddy
 

Home Stereotaxic Instruments Frames without Manipulator Arms Large Species Stereotaxic Frames without Manipulator Arms


Larger Views

 

Large Species Stereotaxic Frames without Manipulator Arms
The Lab Standard™ Large Animal Stereotaxic U-Frame provides superior performance. Up to four manipulator arms may be conveniently positioned on the two parallel rails. Thus, several probes may be independently positioned in one animal.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
724799 Model 51801 Parallel Rail Fame Assembly Only -- 10 days View Pricing
Login to Shop
724801 Model 51851 Stereotaxic Frame Assembly Only, Dog -- 10 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Reliable Locks
• Laser Engraved Scales
• Affordably Priced



The Lab Standard™ Large Animal Stereotaxic U-Frame provides superior performance. Up to four manipulator arms may be conveniently positioned on the two parallel rails. Thus, several probes may be independently positioned in one animal.

Easily Read Scales
Precise, laser engraved graduation lines allow vernier scales to be aligned to a higher degree of accuracy than with other makes of stereotaxic instruments. The numbers are oriented to enhance readability from common user positions.

Reliable Locks
It is at times necessary to tilt the stereotaxic frame to gain access to the animal’s side or underside. A novel locking mechanism makes this tilt both easy to accomplish, and locks securely.

The tilting and angling universal joint on Lab Standard manipulators have the most secure, reliable locks of any stereotaxic instrument.

Components Included
The 51800 comes equipped with:
Two 51804 L.H. Manipulators
Two 51806 R.H. Manipulators
One 51826 Cat/Monkey Head Holder with 18° Ear Bars or One 5182 Dog/Monkey Adaptor
One 51801 Parallel Rail Frame
One 51680 4 x 4 in mounting supportstand.

Base plates are ordered separately. Adaptors for rat, mouse and other species are available.

The 51851 Dog Frame is longer, includes a highly adjustable dog head holder, and 2 sets of ear bar blocks to allow configuration for large dogs.

Accessories
The scales for the 51800 series earbars are in a different position than on the 51600 series. All species adaptors and earbars manufactured by Stoelting are available for the 51600 and 51800 series of stereotaxic instruments, except the Dog Adaptor 51852.

The 51858 A-P Microdrive provides fine movement control in the anterior posterior dimension with 25 mm. range and 10µm graduations. It mounts between the rails and the manipulator. The 51858 includes a longer probe holder shaft to compensate for the extra height.

Base Plates
To complete your Stereotaxic Frame you must purchase a base plate. Two different plates are available. The 51872 base plate has slots for mounting other instruments on the same base with a 51800 series stereotaxic. The 51871 is a 13 x 17 in flat base plate without slots. A 4 x 4 in mounting plate with 2 sets of four mounting holes is included with the 51800 series stereotaxics. One set of holes is on 2 in centers and the other set is on 3.5 in centers.


Specifications Back to Top

Specifications724799724801
Animal Dog

Back to Top



Journal Articles Back to Top

Displaying 1 to 9 of 9 results for Large Species Stereotaxic Frames without Manipulator Arms  

Score

Document

Description

100% Login to view MC02 Species Differences in Pharmacokinetics of a Hepatoprotective Agent.pdf
[168 KB]
Respiration Metabolic Cage use in finding species differences in Pharmacokinetics of a Hepatoprotective agent
62% Login to view BTX02 ECM830.pdf
[172 KB]
Requirement of Species-Specific Interactions for the Activation of Human T Cells by Pamidronate
47% Login to view MC02metabolic cage pump.pdf
[166 KB]
Respiration Metabolic Cage use in finding species differences in Pharmacokinetics of a Hepatoprotective agent
21% Login to view PP57 Quantification of Cerebral Perfusion With Real-Time Contrast-Enhanced Ultrasound.pdf
[210 KB]
Respirator pump use in finding Quantification of Cerebral Perfusion With "Real Time" Contrast-Enhanced Ultrasound
21% Login to view PP112 pmp2002.pdf
[247 KB]
Syringe Pump use in Production of small molecular weight catalysts
21% Login to view VT34 MRI assessment of LV relaxation by untwisting rate.pdf
[231 KB]
MRI assessment of LV relaxation by untwisting rate
15% Login to view HS04 Contractile Efficiency in Hibernating Myocardium.pdf
[79 KB]
Latex Balloon use in finding Benefical Effect of Glucose on Short-Term, Perfusion-Pressure Induced Changes of Contractile Efficiency in Isolated Rabbit Hearts
14% Login to view PP103 Polynuclear Complexes of Copper I and the 2-3-5-Pyrazolyl-6-methylpyridine Ligand.pdf
[253 KB]
Defining Extracellular Integrin Chain Sites That Affect Cell Adhesion and Adhesion Strengthening without Altering Soluble Ligand Binding
14% Login to view PP106 goodprotpmp.pdf
[246 KB]
Defining Extracellular Integrin Chain Sites That Affect Cell Adhesion and Adhesion Strengthening without Altering Soluble Ligand Binding
   

Back to Top



Manuals Back to Top

Displaying 1 to 2 of 2 results for Large Species Stereotaxic Frames without Manipulator Arms  

Score

Document

Description

100% Login to view Stereotaxic Instrument Guide.pdf
[36 KB]
BS4_L_Neuroscience.qxd
87% Login to view Model613 550715.pdf
[270 KB]
Large Animal Volume Controlled Ventilator Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews