Welcome to Harvard Apparatus! — Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources
Shopping Cart Shopping
   Cart
                     My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
Harvard Apparatus

GoDaddy
 

Home Stereotaxic Instruments Digital Manipulator Stereotaxic Instruments Digital Positioning with Digital Manipulator Arm and LED Display Stereotaxic Frame System


Larger Views

 

Digital Positioning with Digital Manipulator Arm and LED Display Stereotaxic Frame System

Add a NEW Digital Manipulator Arm to your Stereotaxic Instruments!
This latest innovation in Standard™ Stereotaxic Instruments features a sealed electronic sensor to each axis of the manipulator arm. This sensor is highly immune to outside interference and environmental conditions. Measurements are accurate to 10 microns in all three directions. Movements in all three directions are now monitored by a large, easy-to-read LED display module, with a resolution selectable from 1 mm to 10 microns.

A zeroing function allows the user to set a reference point for targeting specific coordinates on the animal’s skull for injection, implantation, etc. Calculation of distance measurements via the vernier scales is thus no longer necessary?saving the user valuable time and improving accuracy.

The classic design and high quality of our conventional Lab Standard™ manipulators are exactly the same on the new Digital Stereotaxic, with no drift and smooth movements. The Digital Lab Standard™ keeps the custom triple-start lead screws to allow fast positioning, while maintaining consistently smooth movement. The thin cords from the sensors do not interfere with movements, allowing the arm to move freely and be set at any angle.

Search for Product in current catalog
Item Listing Full Description Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
726039 Digital Manipulator Arm, 3 Axis, Left Hand, and LED Display -- 10 days View Pricing
Login to Shop
726040 Digital Manipulator Arm, 3 Axis, Right Hand, and LED Display -- 10 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Saves time
• Improves accuracy

This latest innovation in Standard™ Stereotaxic Instru-ments features a sealed electronic sensor to each axis of the manipulator arm. This sensor is highly immune to outside interference and environmental conditions. Measurements are accurate to 10 microns in all three directions. Movements in all three directions are now monitored by a large, easy-to-read LED display module, with a resolution selectable from 1 mm to 10 microns.

A zeroing function allows the user to set a reference point for targeting specific coordinates on the animal’s skull for injection, implantation, etc. Calculation of distance measurements via the vernier scales is thus no longer necessary?saving the user valuable time and improving accuracy.

The classic design and high quality of our conventional Lab Standard™ manipulators are exactly the same on the new Digital Stereotaxic, with no drift and smooth movements. The Digital Lab Standard™ keeps the custom triple-start lead screws to allow fast positioning, while maintaining consistently smooth movement. The thin cords from the sensors do not interfere with movements, allowing the arm to move freely and be set at any angle.

Your Choice of Three Options
1. New Digital Lab Standard™ Stereotaxic Instrument complete with LED Digital Display.
2. Add new Digital Manipulator Arms and an LED Display to your current Lab Standard™ or similar brand of stereotaxic.
3. Convert your existing Lab Standard™ (or most other brands) by adding digital sensors to their manipulator arms. LED Display Module included.

Zeroing Function for Targeting Specific Coordinates
The display of each axis can be “ZERO”ed at any location, making operation simple and straightforward. To target a specific location, start at Bregma, and reset all coordinates to zero. Move the manipulator arm to the desired point and lower the electrode, probe, or micropipette into place.

Memory
Target coordinates can be programmed into the memory of the 72-6035 and 72-6037 Digital Lab Standard™ Stereotaxics.

Versatility of Positioning
The universal joint allows the investigator to angle the probe in either the anterior-posterior or the lateral-medial planes. The improved locking mechanism on the Lab Standard™ Stereotaxic Instruments will hold any angled position without slippage. Of course, it also provides an absolute lock at the vertical position. The manipulator arm may be swiveled out of the way for convenience in installing the animal or performing a procedure, then returned to the same point reliably with the aid of the locking face block above the swivel joint.

Accessories
All of the accessories for the Lab Standard™ Small Animal Stereotaxic Instrument fit the 72-6035 and 72-6037 Digital Lab Standard™ Small Animal Stereotaxic Instrument. Probe holders and species adapters for “U” frame stereotaxic instruments made by other manufacturers are generally compatible with the Lab Standard frame.

The 72-6035 and 72-6037 Digital Lab Standard™ Small Animal Stereotaxic Instruments come complete with a standard probe holder with corner clamp and a Rat Adapter with nose holder and 18 degree taper ear bars. The 72-6036 and 72-6038 include the non-puncture (45°) ear bars instead of the 18-degree ear bars. They are otherwise identical to the 72-6035 and 72-6037.

The time-proven U-Frame design concept, rugged construction, and adaptability to most species used in the lab make Stoelting’s Lab Standard™ series the best choice for stereotaxic instruments.


Journal Articles Back to Top

Displaying 1 to 10 of 10 results for Digital Positioning with Digital Manipulator Arm and LED Display Stereotaxic Frame System  

Score

Document

Description

100% Login to view VT32 Digital Optical Imaging to Track Vascular Gene Expression.pdf
[1,004 KB]
Digital Optical Imaging to Track Vascular Gene Expression
74% Login to view VT32 mri vent.pdf
[1.1 MB]
Digital Optical Imaging to Track Vascular Gene Expression
71% Login to view PP43 The Measurement of Blood Flow from Dynamic Digital X-Ray Images Using a Weighted Optical Flow Algorithm.pdf
[202 KB]
Pulsatile Syringe Pump use in finding The Measurement of Blood Flow from Dynamic Digital X-Ray Images Using a Weighted Optical Flow Algorithm
49% Login to view PP43PU 1.PDF
[199 KB]
Pulsatile Syringe Pump use in finding The Measurement of Blood Flow from Dynamic Digital X-Ray Images Using a Weighted Optical Flow Algorithm
44% Login to view Interleukin-12-mediated induction of systemic immunity.pdf
[213 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery and recruitment of activated T cells into the brain produce limited antitumor effects compared with interleukin-2
25% Login to view VT08 Ejection has both positive and negative effects on left ventricular isovolumic relaxation.pdf
[218 KB]
Ejection has both positive and negative effects on left ventricular isovolumic relaxation
23% Login to view VT08 683 pos.pdf
[255 KB]
Ejection has both positive and negative effects on left ventricular isovolumic relaxation
22% Login to view PP41 y2-Melanocyte-Stimulating Hormone Suppression of Systemic Inflammatory Responses to Endotoxin.pdf
[495 KB]
Melanocyte-stimulating hormone suppression of systemic inflammatory responses
12% Login to view PP86.pdf
[180 KB]
Dexenfluramine-Induced Systemic Vasoconstriction
10% Login to view PI12 mri inject.pdf
[201 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery
   

Back to Top



Manuals Back to Top

Displaying 1 to 5 of 5 results for Digital Positioning with Digital Manipulator Arm and LED Display Stereotaxic Frame System  

Score

Document

Description

100% Login to view Stereotaxic Instrument Guide.pdf
[36 KB]
BS4_L_Neuroscience.qxd
86% Login to view metric system trivia.pdf
[146 KB]
Microsoft Word - Lesson1.doc
74% Login to view Perfusion Tissue Systems Guide.pdf
[105 KB]
New BS4_K_Isolated Organ.qxd
70% Login to view 650073 76 Brain Slice Chmbr Manual.pdf
[706 KB]
Brain Slice Chamber System User's Manual
61% Login to view 650073-0076 Manual.pdf
[285 KB]
Brain Slice Chamber System Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews