Home Non-Invasive Blood Pressure NIBP System with Transilluminated LED & Photodiode Sensor Single/Dual Channel Operation Blood Pressure Analysis Systems


Larger Views

 

Single/Dual Channel Operation Blood Pressure Analysis Systems
The SC1000 combines the latest in blood pressure analysis technology with the economy of single channel operation. Measurement results include Pulse Rate, Systolic, Diastolic, and MAP. The system is expandable by easily adding a second specimen platform for use with either mice or rats. All measurement results correlate precisely with intra-arterial methods and the data is automatically saved for exporting to any common spreadsheet. The SC1000 is accurate, efficient and time saving.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
727073 SC1000 Blood Pressure Analysis System for Mice, 85 to 240 VAC, 50/60 Hz**Note: All units are supplied with USA standard power cords. -- 10 days View Pricing
Login to Shop
727074 SC1000 Blood Pressure Analysis System for Rats, 85 to 240 VAC, 50/60 Hz**Note: All units are supplied with USA standard power cords. -- 10 days View Pricing
Login to Shop
727075 Additional Mouse Platform with Size 1 Mouse Holder and CAT5 Cable -- 10 days View Pricing
Login to Shop
727076 Additional Rat Platform with Size 1 Rat Holder and CAT5 Cable -- 10 days View Pricing
Login to Shop
727078 SC1000 Comm for Windows® Software -- 10 days View Pricing
Login to Shop
727079 SC1000 Palm OS® Version Software -- 0 days View Pricing
Login to Shop
727077 Palm PDA (consult factory for models available) -- 0 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Single or Dual Channel Operation (requires additional specimen platform)
• Simultaneous measurements on two animals
• “V-Notch” sensor assembly helps to stabilize the tail
• Interchangeable Specimen Platforms
• Uses standard latex balloons in tail-cuff
• Rugged all metal construction with epoxy coating
• Holders available in four standard sizes
• Custom Algorithms designed specifically for non-invasive measurements
• Fast and Accurate measurements for pulse, diastolic, systolic and MAP
• Precise Correlation with intra-arterial measurements

The SC1000 combines the latest in blood pressure analysis technology with the economy of single channel operation. Measurement results include Pulse Rate, Systolic, Diastolic, and MAP. The system is expandable by easily adding a second specimen platform for use with either mice or rats. All measurement results correlate precisely with intra-arterial methods and the data is automatically saved for exporting to any common spreadsheet. The SC1000 is accurate, efficient and time saving.
The SC1000 incorporates custom algorithms for measuring diastolic blood pressure independently of systolic pressure. Other systems calculate the diastolic pressure based on the systolic measurement. The parameter settings for determining diastolic and systolic BP are adjustable by the user. This feature allows the user to make adjustments to the system settings for correlation with simultaneous intra-arterial measurements.
Measurement data collected by the SC1000 can be retrieved by the user by paging through the measurement results with the keypad and recording them manually as they are displayed on the vacuum fluorescent display. A more automated collection method can by utilized by connecting the SC1000 to a Palm Pilot or other PDA through the onboard RS232 serial port. The PDA Interface works with any Palm OS® based system such as a Palm IIIc® or other handheld device. By using the PDA Interface, measurement data can be automatically stored. The stored data can be imported to a PC for viewing the measurement waveforms. For complete automation, the SC1000 may be connected to a notebook or desktop computer for data collection and control, real-time viewing of the pulse waveform, and storage of all results and waveform data in computer files. The results data and associated waveforms can be retrieved at any time for review and analysis. In addition, the results data can be exported as a .csv file for use in any common spreadsheet.
Pulse Detection is accomplished with a very sensitive solid-state photodiode detector in combination with a high intensity light emitting diode. The specially designed “V” shaped sensor assembly helps stabilize the animals’ tail.
The animal holders are especially designed to minimize the difficulty of securing untrained animals when making blood pressure measurements. Each system is supplied with one size 1 specimen holder. Other size holders are available separately. The control unit can accept a second specimen platform thus making it a dual channel system. The specimen platform is species specific, but the control unit is non-specific. Therefore you may use 2 rat platforms, 2 mice platforms or 1 rat and 1 mouse platform.The SC1000 Blood Pressure Analysis System includes:
• Master Control Unit
• Specimen Platform for either mouse or rat with one size 1 specimen holder
• Airline, power cable and interconnect cable
• Accessory Kit (contains tail-cuff balloons, tool for making end caps, etc.)
• Operator’s Manual
The following is optional equipment or software:
• Additional specimen platform
• Different size specimen holders
• Palm PDA (consult factory for models available)
• SC1000 Palm OS® Version Software
• SC1000 Comm for Windows® Software


Specifications Back to Top

Specifications727073727074727075727076727078727079727077
AnimalMouseRatMouseRat   
Power85 to 240 VAC, 50/60 Hz**Note: All units are supplied with USA standard power cords.85 to 240 VAC, 50/60 Hz**Note: All units are supplied with USA standard power cords.     
Size  11   

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 48 results for Single/Dual Channel Operation Blood Pressure Analysis Systems   Page 1  2  3  4  5 

Score

Document

Description

100% Login to view HS08 pressure transducer.pdf
[46 KB]
Pressure Transducer use in finding blood pressure and heart rate spectral changes
82% Login to view PP50 Blood Pump Model 1421.pdf
[141 KB]
Analysis of Slipstream Flow in a Wide-necked Basilar Artery Aneurysm with use of Blood Pump
63% Login to view PP86.pdf
[180 KB]
Dexenfluramine-Induced Systemic Vasoconstriction
63% Login to view PP50 Analysis of Slipstream Flow in a Wide-Necked Basilar Artery Aneurysm.pdf
[136 KB]
Analysis of Slipstream Flow in a Wide-necked Basilar Artery Aneurysm with use of Blood Pump
60% Login to view Ca21-sensitive Inactivation and Facilitation of L-type Ca21 Channels.pdf
[235 KB]
Ca21-sensitive Inactivation and Facilitation of L-type Ca21 Channels Both Depend on Specific Amino Acid Residues in a Consensus Calmodulin-binding Motif in thea1C subunit
49% Login to view Interleukin-12-mediated induction of systemic immunity.pdf
[213 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery and recruitment of activated T cells into the brain produce limited antitumor effects compared with interleukin-2
45% Login to view WR06 OC724 Amplifier.pdf
[223 KB]
Mutational Analysis of CaM-mediated L-type Channel Modulation
40% Login to view VT13 Air-sac pressures in little penguins.pdf
[142 KB]
Air-sac pressures in little penguins
40% Login to view PP74MO 1.PDF
[290 KB]
Electrospray Tandem Mass Spectrometry for Analysis of Acylcarnitines in Dried Postmortem Blood Specimens
37% Login to view Epithelial Sodium Channels Regulate Cystic Fibrosis.pdf
[223 KB]
Epithelial Sodium Channels Regulate Cystic Fibrosis Transmembrane Conductance Regulator Chloride Channels in Xenopus Oocytes
   

Back to Top



Manuals Back to Top

Displaying 1 to 2 of 2 results for Single/Dual Channel Operation Blood Pressure Analysis Systems  

Score

Document

Description

100% Login to view 603002 603003.pdf
[77 KB]
Research Grade Blood Pressure Transducer Manual
89% Login to view 724488 724489.pdf
[124 KB]
Research Grade Blood Pressure Transducer Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews