Radiation Protection Pipette Shields
Pipette Shields
These specially designed pipette shields fit snugly on the pipette shaft. This protects the hand during the dispensing sequence and enables the user to dispense safely into small and narrow neck containers. Two types of shields are manufactured which are specifically designed to fit either Gilson or Biohit pipettes.

Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles
Item# Description In Stock Lead Time U.S. List Price Quantity
680695 Model RPP-PSG20/100 Pipette Shield, Beta - P20/100, fits Gilson pipettes P20 and P100 -- 10 days View Pricing
Login to Shop
680696 Model RPP-GPSG20/100 Pipette Shield, Gamma - P20/100, fits Gilson pipettes P20 and P100 Yes -- View Pricing
Login to Shop
680697 Model RPP-PSG200 Pipette Shield, Beta - P200, fits Gilson pipette P200 -- 10 days View Pricing
Login to Shop
680698 Model RPP-GPSG200 Pipette Shield, Gamma - P200, fits Gilson pipette P200 Yes -- View Pricing
Login to Shop
680699 Model RPP-PSG1000 Pipette Shield, Beta - P1000, fits Gilson pipette P1000 -- 10 days View Pricing
Login to Shop
680700 Model RPP-GPSG1000 Pipette Shield, Gamma - P1000, fits Gilson pipette P1000 -- 10 days View Pricing
Login to Shop
680689 Model RPP-PS200 Pipette Shield, Beta - PS200, fits Biohit pipettes up to 200 µl -- 10 days View Pricing
Login to Shop
680690 Model RPP-GPS200 Pipette Shield, Gamma - PS200, fits Biohit pipettes up to 200 µl -- 10 days View Pricing
Login to Shop
680691 Model RPP-PS1000 Pipette Shield, Beta - PS1000, fits Biohit pipette 50 - 1000 µl -- 10 days View Pricing
Login to Shop
680692 Model RPP-GPS1000 Pipette Shield, Gamma - PS1000, fits Biohit pipette 50 - 1000 µl -- 10 days View Pricing
Login to Shop
680693 Model RPP-PS5000 Pipette Shield, Beta - PS5000, fits Biohit pipettes up to 1 - 5 ml -- 10 days View Pricing
Login to Shop
680694 Model RPP-GPS5000 Pipette Shield, Gamma - PS5000, fits Biohit pipettes up to 1 - 5 ml -- 10 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Hand protection when pipetting
• For use with Pipetman®
• Convenient to use

Beta Protection Products
Beta emissions of 32P, 35S, 3H and 14C can be effectively blocked by using 10mm thick optical acrylic, which is now the accepted standard for shielding beta emissions in biological research. The properties of this acrylic material are ideal for the construction of beta radiation protection products. It is easy to bend, fabricate and machine into a wide range of products. Also, being transparent, the visibility of the working environment is not impaired.

Gamma Protection Products
Protection from gamma emitting isotopes, such as 125I, 133Xe, 57Co, 99mTe, 123I and 67Ga has, until recently, been achieved by lead shielding. This has its obvious disadvantages, being very heavy and non-transparent. However, a new lead containing acrylic co-polymer resin is now readily available. The lead content of the resin is 30% wt/wt and is chemically introduced into the acrylic resin as an organolead salt. This material is transparent with a very light brown tint and it exhibits virtually all the normal chemical and physical properties of conventional acrylic resin. Scie-Plas Limited provide a range of products using 12mm thick lead-acrylic, which is equivalent to 0.5mm thick lead. This range of products effectively blocks gamma emissions from 125I and any gamma emitters of lesser energy. It is NOT suitable for use with more energetic isotopes of iodine. However, a 35mm thick shield is available, which is equivalent to 1.7mm thick lead, which can be used with isotopes of higher energy.

SAFETY PRECAUTION
12mm thick lead-acrylic is suitable only for the protection of gamma emissions from 125I and not from other higher energetic isotopes of iodine.Lead or lead-acrylic is not recommended for shielding beta emissions. When a beta particle collides with an atom with a high atomic number, such as lead, a hazardous X-ray-like emission, known as BREMSSTRHBLUNG is generated. To avoid producing significant amounts of bremsstrhblung, use only optical clear acrylic products to shield beta emissions.
Radioactive compounds have been used in research laboratories for many years and the results of this research have benefited mankind considerably. In life science research, radioactive compounds are used in the detection of nucleic acids and proteins as well as in many other techniques such as radioimmunoassay and as tracers in metabolic studies. The most often used isotopes which emit beta (ß) radiation particles are: [32P] phosphorous, [35S] sulphur, [14C] carbon and [3H] tritium. While [125I] iodine, [133Xe] xenon, [57Co] cobalt, [99mTe] technetium, [123I] iodine and [67Ga] gallium, emit gamma (g) particles.
Generally, beta emissions are negatively charged particles (electrons), emitted from the nucleus of an atom. Depending on the particular atom, the energy level of the charged particle will vary. Phosphorous is regarded as having a high energy level of beta radiation particles, being 10 times greater than that of tritium, and which can travel up to seven metres in air. Phosphorous is therefore known as a "hard" emitter of beta radiation, while tritium, sulphur and carbon are regarded as "soft" emitters of beta radiation.
125I is a weak emitter of gamma radiation particles. Gamma emissions are a form of electromagnetic radiation similar to that of light, generated by the nuclear decay of an unstable isotope. They are much more penetrating than beta emissions and can travel very long distances in air.
Custom Built Products
Scie-Plas Limited manufacture the complete range of radiation protection products shown in this catalogue. Many styles and sizes of apparatus are listed for use with different applications. However, if you cannot find the exact product you are looking for, it can be custom made to your specific requirements at little extra cost. Please contact Scie-Plas for a quotation.


Specifications Back to Top

Specifications680695680696680697680698680699680700680689680690680691680692680693680694
Compatible PipetteP20/100, fits Gilson pipettes P20 and P100P20/100, fits Gilson pipettes P20 and P100P200, fits Gilson pipette P200P200, fits Gilson pipette P200P1000, fits Gilson pipette P1000P1000, fits Gilson pipette P1000PS200, fits Biohit pipettes up to 200 µlPS200, fits Biohit pipettes up to 200 µlPS1000, fits Biohit pipette 50 - 1000 µlPS1000, fits Biohit pipette 50 - 1000 µlPS5000, fits Biohit pipettes up to 1 - 5 mlPS5000, fits Biohit pipettes up to 1 - 5 ml
MaterialClear Optical AcrylicClear Lead AcrylicClear Optical AcrylicClear Lead AcrylicClear Optical AcrylicClear Lead AcrylicClear Optical AcrylicClear Lead AcrylicClear Optical AcrylicClear Lead AcrylicClear Optical AcrylicClear Lead Acrylic
ModelRPP-PSG20/100RPP-GPSG20/100RPP-PSG200RPP-GPSG200RPP-PSG1000RPP-GPSG1000RPP-PS200RPP-GPS200RPP-PS1000RPP-GPS1000RPP-PS5000RPP-GPS5000
Radiation ProtectionBetaGammaBetaGammaBetaGammaBetaGammaBetaGammaBetaGamma
Thickness Metric10 mm12 mm10 mm12 mm10 mm12 mm10 mm12 mm10 mm12 mm10 mm12 mm

Back to Top



Journal Articles Back to Top

Displaying 1 to 4 of 4 results for Radiation Protection Pipette Shields  

Score

Document

Description

100% Login to view PP97 bsc25pump.pdf
[167 KB]
Infusion Pump use in finding p38 Inhibitor Protects the Brain
70% Login to view PP78.pdf
[1.2 MB]
B-Lactamase binds to GroEL in a conformation highly protected against hydrogen/deuterium exchange
70% Login to view PP78 B-Lactamase Binds To GroEl In A Conformation Highly Protected Against Hydrogen-Deuterium Exchange.pdf
[274 KB]
NH2-terminal Proline Acts as a Nucleophile in the Glycosylase/AP-Lyase Reaction
32% Login to view VT26 Mini Ventilator 845.pdf
[1.2 MB]
Mini Ventilator use in finding Heterozygous deficiency of hypoxia-inducible factor 2a
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews